]> git.ipfire.org Git - thirdparty/cups.git/blob - doc/help/ref-snmp-conf.html
92d8f375a1d8052f684b54fe328808b1d031abef
[thirdparty/cups.git] / doc / help / ref-snmp-conf.html
1 <HTML>
2 <!-- SECTION: References -->
3 <HEAD>
4 <TITLE>snmp.conf</TITLE>
5 </HEAD>
6 <BODY>
7
8 <P>The <VAR>/etc/cups/snmp.conf</VAR> file contains several
9 directives that determine how the SNMP printer discovery backend
10 behaves. Each directive is listed on a line by itself followed
11 by its value. Comments are introduced using the number sign ("#")
12 character at the beginning of a line.</P>
13
14 <P>The SNMP backend uses the SNMPv1 protocol to discover network
15 printers, collecting information from the Host MIB along with
16 intelligent port probes to determine the correct device URI and
17 make and model for each printer. Future versions of CUPS will
18 likely support the new Port Monitor MIB as well.</P>
19
20 <H2 CLASS="title"><A NAME="Address">Address</A></H2>
21
22 <H3>Examples</H3>
23
24 <PRE CLASS="command">
25 Address @LOCAL
26 Address @IF(name)
27 Address 255.255.255.255
28 Address 192.168.2.255
29 </PRE>
30
31 <H3>Description</H3>
32
33 <P>The <CODE>Address</CODE> directive specifies a broadcast
34 address to use when discovering printers. Multiple
35 <CODE>Address</CODE> lines can be provided to scan different
36 subnets.</P>
37
38 <P>The default address is <VAR>@LOCAL</VAR>, which broadcasts to
39 all LANs.</P>
40
41
42 <H2 CLASS="title"><A NAME="Community">Community</A></H2>
43
44 <H3>Examples</H3>
45
46 <PRE CLASS="command">
47 Community public
48 Community easysw
49 Community BigCorp
50 </PRE>
51
52 <H3>Description</H3>
53
54 <P>The <CODE>Community</CODE> directive specifies a community
55 name to use when discovering printers. Multiple
56 <CODE>Community</CODE> lines can be provided to scan different
57 SNMP communities.</P>
58
59 <P>The default community is "public".</P>
60
61
62 <H2 CLASS="title"><A NAME="DebugLevel">DebugLevel</A></H2>
63
64 <H3>Examples</H3>
65
66 <PRE CLASS="command">
67 DebugLevel 0
68 DebugLevel 1
69 DebugLevel 2
70 DebugLevel 3
71 </PRE>
72
73 <H3>Description</H3>
74
75 <P>The <CODE>DebugLevel</CODE> directive specifies the debugging
76 level to use when searching for network printers. Level 0
77 produces no debugging information. Level 1 produces basic
78 debugging information. Level 2 adds printing of the SNMP
79 messages. Level 3 adds a hex dump of the network data.</P>
80
81 <P>The default setting is <VAR>0</VAR>.</P>
82
83 <H2 CLASS="title"><A NAME="HostNameLookups">HostNameLookups</A></H2>
84
85 <H3>Examples</H3>
86
87 <PRE CLASS="command">
88 HostNameLookups on
89 HostNameLookups off
90 </PRE>
91
92 <H3>Description</H3>
93
94 <P>The <CODE>HostNameLookups</CODE> directive specifies whether printer
95 addresses are converted to hostnames or left as numeric IP addresses.</P>
96
97 <P>The default setting is <VAR>off</VAR>.</P>