ARM: dts: meson8: Fix the UART device-tree schema validation
authorMartin Blumenstingl <martin.blumenstingl@googlemail.com>
Mon, 27 Dec 2021 18:00:25 +0000 (19:00 +0100)
committerNeil Armstrong <narmstrong@baylibre.com>
Mon, 10 Jan 2022 09:32:51 +0000 (10:32 +0100)
The dt-bindings for the UART controller only allow the following values
for Meson8 SoCs:
- "amlogic,meson8-uart", "amlogic,meson-ao-uart"
- "amlogic,meson8-uart"

Use the correct fallback compatible string "amlogic,meson-ao-uart" for
AO UART. Drop the "amlogic,meson-uart" compatible string from the EE
domain UART controllers.

Also update the order of the clocks to match the order defined in the
yaml schema.

Fixes: 6ca77502050eff ("ARM: dts: meson8: use stable UART bindings with correct gate clock")
Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
Signed-off-by: Neil Armstrong <narmstrong@baylibre.com>
Link: https://lore.kernel.org/r/20211227180026.4068352-3-martin.blumenstingl@googlemail.com
arch/arm/boot/dts/meson8.dtsi

index f80ddc98d3a2b20697c7daeae372c72d074cf96f..9997a5d0333a3f7339136dfe4eeecb9bfe148a55 100644 (file)
 };
 
 &uart_AO {
-       compatible = "amlogic,meson8-uart", "amlogic,meson-uart";
-       clocks = <&clkc CLKID_CLK81>, <&xtal>, <&clkc CLKID_CLK81>;
-       clock-names = "baud", "xtal", "pclk";
+       compatible = "amlogic,meson8-uart", "amlogic,meson-ao-uart";
+       clocks = <&xtal>, <&clkc CLKID_CLK81>, <&clkc CLKID_CLK81>;
+       clock-names = "xtal", "pclk", "baud";
 };
 
 &uart_A {
-       compatible = "amlogic,meson8-uart", "amlogic,meson-uart";
-       clocks = <&clkc CLKID_CLK81>, <&xtal>, <&clkc CLKID_UART0>;
-       clock-names = "baud", "xtal", "pclk";
+       compatible = "amlogic,meson8-uart";
+       clocks = <&xtal>, <&clkc CLKID_UART0>, <&clkc CLKID_CLK81>;
+       clock-names = "xtal", "pclk", "baud";
 };
 
 &uart_B {
-       compatible = "amlogic,meson8-uart", "amlogic,meson-uart";
-       clocks = <&clkc CLKID_CLK81>, <&xtal>, <&clkc CLKID_UART1>;
-       clock-names = "baud", "xtal", "pclk";
+       compatible = "amlogic,meson8-uart";
+       clocks = <&xtal>, <&clkc CLKID_UART0>, <&clkc CLKID_CLK81>;
+       clock-names = "xtal", "pclk", "baud";
 };
 
 &uart_C {
-       compatible = "amlogic,meson8-uart", "amlogic,meson-uart";
-       clocks = <&clkc CLKID_CLK81>, <&xtal>, <&clkc CLKID_UART2>;
-       clock-names = "baud", "xtal", "pclk";
+       compatible = "amlogic,meson8-uart";
+       clocks = <&xtal>, <&clkc CLKID_UART0>, <&clkc CLKID_CLK81>;
+       clock-names = "xtal", "pclk", "baud";
 };
 