1 .\" Copyright Neil Brown and others.
2 .\" This program is free software; you can redistribute it and/or modify
3 .\" it under the terms of the GNU General Public License as published by
4 .\" the Free Software Foundation; either version 2 of the License, or
5 .\" (at your option) any later version.
6 .\" See file COPYING in distribution for details.
7 .TH MD 4
8 .SH NAME
9 md \- Multiple Device driver aka Linux Software RAID
10 .SH SYNOPSIS
11 .BI /dev/md n
12 .br
13 .BI /dev/md/ n
14 .br
15 .BR /dev/md/ name
16 .SH DESCRIPTION
17 The
18 .B md
19 driver provides virtual devices that are created from one or more
20 independent underlying devices. This array of devices often contains
21 redundancy and the devices are often disk drives, hence the acronym RAID
22 which stands for a Redundant Array of Independent Disks.
23 .PP
24 .B md
25 supports RAID levels
26 1 (mirroring),
27 4 (striped array with parity device),
28 5 (striped array with distributed parity information),
29 6 (striped array with distributed dual redundancy information), and
30 10 (striped and mirrored).
31 If some number of underlying devices fails while using one of these
32 levels, the array will continue to function; this number is one for
33 RAID levels 4 and 5, two for RAID level 6, and all but one (N-1) for
34 RAID level 1, and dependent on configuration for level 10.
35 .PP
36 .B md
37 also supports a number of pseudo RAID (non-redundant) configurations
38 including RAID0 (striped array), LINEAR (catenated array),
39 MULTIPATH (a set of different interfaces to the same device),
40 and FAULTY (a layer over a single device into which errors can be injected).
41
42 .SS MD METADATA
43 Each device in an array may have some
44 .I metadata
45 stored in the device. This metadata is sometimes called a
46 .BR superblock .
47 The metadata records information about the structure and state of the array.
48 This allows the array to be reliably re-assembled after a shutdown.
49
50 From Linux kernel version 2.6.10,
51 .B md
52 provides support for two different formats of metadata, and
53 other formats can be added. Prior to this release, only one format is
54 supported.
55
56 The common format \(em known as version 0.90 \(em has
57 a superblock that is 4K long and is written into a 64K aligned block that
58 starts at least 64K and less than 128K from the end of the device
59 (i.e. to get the address of the superblock round the size of the
60 device down to a multiple of 64K and then subtract 64K).
61 The available size of each device is the amount of space before the
62 super block, so between 64K and 128K is lost when a device in
63 incorporated into an MD array.
64 This superblock stores multi-byte fields in a processor-dependent
65 manner, so arrays cannot easily be moved between computers with
66 different processors.
67
68 The new format \(em known as version 1 \(em has a superblock that is
69 normally 1K long, but can be longer. It is normally stored between 8K
70 and 12K from the end of the device, on a 4K boundary, though
71 variations can be stored at the start of the device (version 1.1) or 4K from
72 the start of the device (version 1.2).
73 This metadata format stores multibyte data in a
74 processor-independent format and supports up to hundreds of
75 component devices (version 0.90 only supports 28).
76
77 The metadata contains, among other things:
78 .TP
79 LEVEL
80 The manner in which the devices are arranged into the array
81 (linear, raid0, raid1, raid4, raid5, raid10, multipath).
82 .TP
83 UUID
84 a 128 bit Universally Unique Identifier that identifies the array that
85 contains this device.
86
87 .PP
88 When a version 0.90 array is being reshaped (e.g. adding extra devices
89 to a RAID5), the version number is temporarily set to 0.91. This
90 ensures that if the reshape process is stopped in the middle (e.g. by
91 a system crash) and the machine boots into an older kernel that does
92 not support reshaping, then the array will not be assembled (which
93 would cause data corruption) but will be left untouched until a kernel
94 that can complete the reshape processes is used.
95
96 .SS ARRAYS WITHOUT METADATA
97 While it is usually best to create arrays with superblocks so that
98 they can be assembled reliably, there are some circumstances when an
99 array without superblocks is preferred. These include:
100 .TP
101 LEGACY ARRAYS
102 Early versions of the
103 .B md
104 driver only supported Linear and Raid0 configurations and did not use
105 a superblock (which is less critical with these configurations).
106 While such arrays should be rebuilt with superblocks if possible,
107 .B md
108 continues to support them.
109 .TP
110 FAULTY
111 Being a largely transparent layer over a different device, the FAULTY
112 personality doesn't gain anything from having a superblock.
113 .TP
114 MULTIPATH
115 It is often possible to detect devices which are different paths to
116 the same storage directly rather than having a distinctive superblock
117 written to the device and searched for on all paths. In this case,
118 a MULTIPATH array with no superblock makes sense.
119 .TP
120 RAID1
121 In some configurations it might be desired to create a raid1
122 configuration that does not use a superblock, and to maintain the state of
123 the array elsewhere. While not encouraged for general us, it does
124 have special-purpose uses and is supported.
125
126 .SS ARRAYS WITH EXTERNAL METADATA
127
128 From release 2.6.28, the
129 .I md
130 driver supports arrays with externally managed metadata. That is,
131 the metadata is not managed by the kernel by rather by a user-space
132 program which is external to the kernel. This allows support for a
133 variety of metadata formats without cluttering the kernel with lots of
134 details.
135 .PP
136 .I md
137 is able to communicate with the user-space program through various
138 sysfs attributes so that it can make appropriate changes to the
139 metadata \- for example to make a device as faulty. When necessary,
140 .I md
141 will wait for the program to acknowledge the event by writing to a
142 sysfs attribute.
143 The manual page for
144 .IR mdmon (8)
145 contains more detail about this interaction.
146
147 .SS CONTAINERS
148 Many metadata formats use a single block of metadata to describe a
149 number of different arrays which all use the same set of devices.
150 In this case it is helpful for the kernel to know about the full set
151 of devices as a whole. This set is known to md as a
152 .IR container .
153 A container is an
154 .I md
155 array with externally managed metadata and with device offset and size
156 so that it just covers the metadata part of the devices. The
157 remainder of each device is available to be incorporated into various
158 arrays.
159
160 .SS LINEAR
161
162 A linear array simply catenates the available space on each
163 drive to form one large virtual drive.
164
165 One advantage of this arrangement over the more common RAID0
166 arrangement is that the array may be reconfigured at a later time with
167 an extra drive, so the array is made bigger without disturbing the
168 data that is on the array. This can even be done on a live
169 array.
170
171 If a chunksize is given with a LINEAR array, the usable space on each
172 device is rounded down to a multiple of this chunksize.
173
174 .SS RAID0
175
176 A RAID0 array (which has zero redundancy) is also known as a
177 striped array.
178 A RAID0 array is configured at creation with a
179 .B "Chunk Size"
180 which must be a power of two (prior to Linux 2.6.31), and at least 4
181 kibibytes.
182
183 The RAID0 driver assigns the first chunk of the array to the first
184 device, the second chunk to the second device, and so on until all
185 drives have been assigned one chunk. This collection of chunks forms a
186 .BR stripe .
187 Further chunks are gathered into stripes in the same way, and are
188 assigned to the remaining space in the drives.
189
190 If devices in the array are not all the same size, then once the
191 smallest device has been exhausted, the RAID0 driver starts
192 collecting chunks into smaller stripes that only span the drives which
193 still have remaining space.
194
195
196 .SS RAID1
197
198 A RAID1 array is also known as a mirrored set (though mirrors tend to
199 provide reflected images, which RAID1 does not) or a plex.
200
201 Once initialised, each device in a RAID1 array contains exactly the
202 same data. Changes are written to all devices in parallel. Data is
203 read from any one device. The driver attempts to distribute read
204 requests across all devices to maximise performance.
205
206 All devices in a RAID1 array should be the same size. If they are
207 not, then only the amount of space available on the smallest device is
208 used (any extra space on other devices is wasted).
209
210 Note that the read balancing done by the driver does not make the RAID1
211 performance profile be the same as for RAID0; a single stream of
212 sequential input will not be accelerated (e.g. a single dd), but
213 multiple sequential streams or a random workload will use more than one
214 spindle. In theory, having an N-disk RAID1 will allow N sequential
215 threads to read from all disks.
216
217 Individual devices in a RAID1 can be marked as "write-mostly".
218 This drives are excluded from the normal read balancing and will only
219 be read from when there is no other option. This can be useful for
220 devices connected over a slow link.
221
222 .SS RAID4
223
224 A RAID4 array is like a RAID0 array with an extra device for storing
225 parity. This device is the last of the active devices in the
226 array. Unlike RAID0, RAID4 also requires that all stripes span all
227 drives, so extra space on devices that are larger than the smallest is
228 wasted.
229
230 When any block in a RAID4 array is modified, the parity block for that
231 stripe (i.e. the block in the parity device at the same device offset
232 as the stripe) is also modified so that the parity block always
233 contains the "parity" for the whole stripe. I.e. its content is
234 equivalent to the result of performing an exclusive-or operation
235 between all the data blocks in the stripe.
236
237 This allows the array to continue to function if one device fails.
238 The data that was on that device can be calculated as needed from the
239 parity block and the other data blocks.
240
241 .SS RAID5
242
243 RAID5 is very similar to RAID4. The difference is that the parity
244 blocks for each stripe, instead of being on a single device, are
245 distributed across all devices. This allows more parallelism when
246 writing, as two different block updates will quite possibly affect
247 parity blocks on different devices so there is less contention.
248
249 This also allows more parallelism when reading, as read requests are
250 distributed over all the devices in the array instead of all but one.
251
252 .SS RAID6
253
254 RAID6 is similar to RAID5, but can handle the loss of any \fItwo\fP
255 devices without data loss. Accordingly, it requires N+2 drives to
256 store N drives worth of data.
257
258 The performance for RAID6 is slightly lower but comparable to RAID5 in
259 normal mode and single disk failure mode. It is very slow in dual
260 disk failure mode, however.
261
262 .SS RAID10
263
264 RAID10 provides a combination of RAID1 and RAID0, and is sometimes known
265 as RAID1+0. Every datablock is duplicated some number of times, and
266 the resulting collection of datablocks are distributed over multiple
267 drives.
268
269 When configuring a RAID10 array, it is necessary to specify the number
270 of replicas of each data block that are required (this will normally
271 be 2) and whether the replicas should be 'near', 'offset' or 'far'.
272 (Note that the 'offset' layout is only available from 2.6.18).
273
274 When 'near' replicas are chosen, the multiple copies of a given chunk
275 are laid out consecutively across the stripes of the array, so the two
276 copies of a datablock will likely be at the same offset on two
277 adjacent devices.
278
279 When 'far' replicas are chosen, the multiple copies of a given chunk
280 are laid out quite distant from each other. The first copy of all
281 data blocks will be striped across the early part of all drives in
282 RAID0 fashion, and then the next copy of all blocks will be striped
283 across a later section of all drives, always ensuring that all copies
284 of any given block are on different drives.
285
286 The 'far' arrangement can give sequential read performance equal to
287 that of a RAID0 array, but at the cost of reduced write performance.
288
289 When 'offset' replicas are chosen, the multiple copies of a given
290 chunk are laid out on consecutive drives and at consecutive offsets.
291 Effectively each stripe is duplicated and the copies are offset by one
292 device. This should give similar read characteristics to 'far' if a
293 suitably large chunk size is used, but without as much seeking for
294 writes.
295
296 It should be noted that the number of devices in a RAID10 array need
297 not be a multiple of the number of replica of each data block; however,
298 there must be at least as many devices as replicas.
299
300 If, for example, an array is created with 5 devices and 2 replicas,
301 then space equivalent to 2.5 of the devices will be available, and
302 every block will be stored on two different devices.
303
304 Finally, it is possible to have an array with both 'near' and 'far'
305 copies. If an array is configured with 2 near copies and 2 far
306 copies, then there will be a total of 4 copies of each block, each on
307 a different drive. This is an artifact of the implementation and is
308 unlikely to be of real value.
309
310 .SS MULTIPATH
311
312 MULTIPATH is not really a RAID at all as there is only one real device
313 in a MULTIPATH md array. However there are multiple access points
314 (paths) to this device, and one of these paths might fail, so there
315 are some similarities.
316
317 A MULTIPATH array is composed of a number of logically different
318 devices, often fibre channel interfaces, that all refer the the same
319 real device. If one of these interfaces fails (e.g. due to cable
320 problems), the multipath driver will attempt to redirect requests to
321 another interface.
322
323 The MULTIPATH drive is not receiving any ongoing development and
324 should be considered a legacy driver. The device-mapper based
325 multipath drivers should be preferred for new installations.
326
327 .SS FAULTY
328 The FAULTY md module is provided for testing purposes. A faulty array
329 has exactly one component device and is normally assembled without a
330 superblock, so the md array created provides direct access to all of
331 the data in the component device.
332
333 The FAULTY module may be requested to simulate faults to allow testing
334 of other md levels or of filesystems. Faults can be chosen to trigger
335 on read requests or write requests, and can be transient (a subsequent
336 read/write at the address will probably succeed) or persistent
337 (subsequent read/write of the same address will fail). Further, read
338 faults can be "fixable" meaning that they persist until a write
339 request at the same address.
340
341 Fault types can be requested with a period. In this case, the fault
342 will recur repeatedly after the given number of requests of the
343 relevant type. For example if persistent read faults have a period of
344 100, then every 100th read request would generate a fault, and the
345 faulty sector would be recorded so that subsequent reads on that
346 sector would also fail.
347
348 There is a limit to the number of faulty sectors that are remembered.
349 Faults generated after this limit is exhausted are treated as
350 transient.
351
352 The list of faulty sectors can be flushed, and the active list of
353 failure modes can be cleared.
354
355 .SS UNCLEAN SHUTDOWN
356
357 When changes are made to a RAID1, RAID4, RAID5, RAID6, or RAID10 array
358 there is a possibility of inconsistency for short periods of time as
359 each update requires at least two block to be written to different
360 devices, and these writes probably won't happen at exactly the same
361 time. Thus if a system with one of these arrays is shutdown in the
362 middle of a write operation (e.g. due to power failure), the array may
363 not be consistent.
364
365 To handle this situation, the md driver marks an array as "dirty"
366 before writing any data to it, and marks it as "clean" when the array
367 is being disabled, e.g. at shutdown. If the md driver finds an array
368 to be dirty at startup, it proceeds to correct any possibly
369 inconsistency. For RAID1, this involves copying the contents of the
370 first drive onto all other drives. For RAID4, RAID5 and RAID6 this
371 involves recalculating the parity for each stripe and making sure that
372 the parity block has the correct data. For RAID10 it involves copying
373 one of the replicas of each block onto all the others. This process,
374 known as "resynchronising" or "resync" is performed in the background.
375 The array can still be used, though possibly with reduced performance.
376
377 If a RAID4, RAID5 or RAID6 array is degraded (missing at least one
378 drive, two for RAID6) when it is restarted after an unclean shutdown, it cannot
379 recalculate parity, and so it is possible that data might be
380 undetectably corrupted. The 2.4 md driver
381 .B does not
382 alert the operator to this condition. The 2.6 md driver will fail to
383 start an array in this condition without manual intervention, though
384 this behaviour can be overridden by a kernel parameter.
385
386 .SS RECOVERY
387
388 If the md driver detects a write error on a device in a RAID1, RAID4,
389 RAID5, RAID6, or RAID10 array, it immediately disables that device
390 (marking it as faulty) and continues operation on the remaining
391 devices. If there are spare drives, the driver will start recreating
392 on one of the spare drives the data which was on that failed drive,
393 either by copying a working drive in a RAID1 configuration, or by
394 doing calculations with the parity block on RAID4, RAID5 or RAID6, or
395 by finding and copying originals for RAID10.
396
397 In kernels prior to about 2.6.15, a read error would cause the same
398 effect as a write error. In later kernels, a read-error will instead
399 cause md to attempt a recovery by overwriting the bad block. i.e. it
400 will find the correct data from elsewhere, write it over the block
401 that failed, and then try to read it back again. If either the write
402 or the re-read fail, md will treat the error the same way that a write
403 error is treated, and will fail the whole device.
404
405 While this recovery process is happening, the md driver will monitor
406 accesses to the array and will slow down the rate of recovery if other
407 activity is happening, so that normal access to the array will not be
408 unduly affected. When no other activity is happening, the recovery
409 process proceeds at full speed. The actual speed targets for the two
410 different situations can be controlled by the
411 .B speed_limit_min
412 and
413 .B speed_limit_max
414 control files mentioned below.
415
416 .SS SCRUBBING AND MISMATCHES
417
418 As storage devices can develop bad blocks at any time it is valuable
419 to regularly read all blocks on all devices in an array so as to catch
420 such bad blocks early. This process is called
421 .IR scrubbing .
422
423 md arrays can be scrubbed by writing either
424 .I check
425 or
426 .I repair
427 to the file
428 .I md/sync_action
429 in the
430 .I sysfs
431 directory for the device.
432
433 Writing
434 .I check
435 will cause
436 .I md
437 to read every block on every device in the array, and check that the
438 data is consistent. For RAID1, this means checking that the copies
439 are identical. For RAID5 this means checking that the parity block is
440 correct.
441
442 If a read error is detected during this process, the normal read-error
443 handling causes correct data to be found from other devices and to be
444 written back to the faulty device. In many case this will
445 effectively
446 .I fix
447 the bad block.
448
449 If all blocks read successfully but are found to not be consistent,
450 then this is regarded as a
451 .IR mismatch .
452
453 If
454 .I check
455 was used, then no action is taken to handle the mismatch, it is simply
456 recorded.
457 If
458 .I repair
459 was used, then a mismatch will be repaired in the same way that
460 .I resync
461 repairs arrays. For RAID5 a new parity block is written. For RAID1,
462 all but one block are overwritten with the content of that one block.
463
464 A count of mismatches is recorded in the
465 .I sysfs
466 file
467 .IR md/mismatch_cnt .
468 This is set to zero when a
469 .I check
470 or
471 .I repair
472 process starts and is incremented whenever a sector is
473 found that is a mismatch.
474 .I md
475 normally works in units much larger than a single sector and when it
476 finds a mismatch, it does not find out how many actual sectors were
477 affected but simply add the number of sectors in the IO unit that was
478 used. So a value of 128 could simply mean that a single 64K check
479 found an error.
480
481 If an array is created by mdadm with
482 .I \-\-assume\-clean
483 then a subsequent check could be expected to find some mismatches.
484
485 On a truly clean RAID5 or RAID6 array, any mismatches should indicate
486 a hardware problem at some level - software issues should never cause
487 such a mismatch.
488
489 However on RAID1 and RAID10 it is possible for software issues to
490 cause a mismatch to be reported. This does not necessarily mean that
491 the data on the array is corrupted. It could simply be that the
492 system does not care what is stored on that part of the array - it is
493 unused space.
494
495 The most likely cause for an unexpected mismatch on RAID1 or RAID10
496 occurs if a swap partition or swap file is stored on the array.
497
498 When the swap subsystem wants to write a page of memory out, it flags
499 the page as 'clean' in the memory manager and requests the swap device
500 to write it out. It is quite possible that the memory will be
501 changed while the write-out is happening. In that case the 'clean'
502 flag will be found to be clear when the write completes and so the
503 swap subsystem will simply forget that the swapout had been attempted,
504 and will possibly choose an different page to write out.
505
506 If the swap devices was on RAID1 (or RAID10), then the data is sent
507 from memory to a device twice (or more depending on the number of
508 devices in the array). So it is possible that the memory gets changed
509 between the two times it is sent, so different data can be written to
510 the devices in the array. This will be detected by
511 .I check
512 as a mismatch. However it does not reflect any corruption as the
513 block where this mismatch occurs is being treated by the swap system as
514 being empty, and the data will never be read from that block.
515
516 It is conceivable for a similar situation to occur on non-swap files,
517 though it is less likely.
518
519 Thus the
520 .I mismatch_cnt
521 value can not be interpreted very reliably on RAID1 or RAID10,
522 especially when the device is used for swap.
523
524
525 .SS BITMAP WRITE-INTENT LOGGING
526
527 From Linux 2.6.13,
528 .I md
529 supports a bitmap based write-intent log. If configured, the bitmap
530 is used to record which blocks of the array may be out of sync.
531 Before any write request is honoured, md will make sure that the
532 corresponding bit in the log is set. After a period of time with no
533 writes to an area of the array, the corresponding bit will be cleared.
534
535 This bitmap is used for two optimisations.
536
537 Firstly, after an unclean shutdown, the resync process will consult
538 the bitmap and only resync those blocks that correspond to bits in the
539 bitmap that are set. This can dramatically reduce resync time.
540
541 Secondly, when a drive fails and is removed from the array, md stops
542 clearing bits in the intent log. If that same drive is re-added to
543 the array, md will notice and will only recover the sections of the
544 drive that are covered by bits in the intent log that are set. This
545 can allow a device to be temporarily removed and reinserted without
546 causing an enormous recovery cost.
547
548 The intent log can be stored in a file on a separate device, or it can
549 be stored near the superblocks of an array which has superblocks.
550
551 It is possible to add an intent log to an active array, or remove an
552 intent log if one is present.
553
554 In 2.6.13, intent bitmaps are only supported with RAID1. Other levels
555 with redundancy are supported from 2.6.15.
556
557 .SS WRITE-BEHIND
558
559 From Linux 2.6.14,
560 .I md
561 supports WRITE-BEHIND on RAID1 arrays.
562
563 This allows certain devices in the array to be flagged as
564 .IR write-mostly .
565 MD will only read from such devices if there is no
566 other option.
567
568 If a write-intent bitmap is also provided, write requests to
569 write-mostly devices will be treated as write-behind requests and md
570 will not wait for writes to those requests to complete before
571 reporting the write as complete to the filesystem.
572
573 This allows for a RAID1 with WRITE-BEHIND to be used to mirror data
574 over a slow link to a remote computer (providing the link isn't too
575 slow). The extra latency of the remote link will not slow down normal
576 operations, but the remote system will still have a reasonably
577 up-to-date copy of all data.
578
579 .SS RESTRIPING
580
581 .IR Restriping ,
582 also known as
583 .IR Reshaping ,
584 is the processes of re-arranging the data stored in each stripe into a
585 new layout. This might involve changing the number of devices in the
586 array (so the stripes are wider), changing the chunk size (so stripes
587 are deeper or shallower), or changing the arrangement of data and
588 parity (possibly changing the raid level, e.g. 1 to 5 or 5 to 6).
589
590 As of Linux 2.6.17, md can reshape a raid5 array to have more
591 devices. Other possibilities may follow in future kernels.
592
593 During any stripe process there is a 'critical section' during which
594 live data is being overwritten on disk. For the operation of
595 increasing the number of drives in a raid5, this critical section
596 covers the first few stripes (the number being the product of the old
597 and new number of devices). After this critical section is passed,
598 data is only written to areas of the array which no longer hold live
599 data \(em the live data has already been located away.
600
601 md is not able to ensure data preservation if there is a crash
602 (e.g. power failure) during the critical section. If md is asked to
603 start an array which failed during a critical section of restriping,
604 it will fail to start the array.
605
606 To deal with this possibility, a user-space program must
607 .IP \(bu 4
608 Disable writes to that section of the array (using the
609 .B sysfs
610 interface),
611 .IP \(bu 4
612 take a copy of the data somewhere (i.e. make a backup),
613 .IP \(bu 4
614 allow the process to continue and invalidate the backup and restore
615 write access once the critical section is passed, and
616 .IP \(bu 4
617 provide for restoring the critical data before restarting the array
618 after a system crash.
619 .PP
620
621 .B mdadm
622 versions from 2.4 do this for growing a RAID5 array.
623
624 For operations that do not change the size of the array, like simply
625 increasing chunk size, or converting RAID5 to RAID6 with one extra
626 device, the entire process is the critical section. In this case, the
627 restripe will need to progress in stages, as a section is suspended,
628 backed up,
629 restriped, and released; this is not yet implemented.
630
631 .SS SYSFS INTERFACE
632 Each block device appears as a directory in
633 .I sysfs
634 (which is usually mounted at
635 .BR /sys ).
636 For MD devices, this directory will contain a subdirectory called
637 .B md
638 which contains various files for providing access to information about
639 the array.
640
641 This interface is documented more fully in the file
642 .B Documentation/md.txt
643 which is distributed with the kernel sources. That file should be
644 consulted for full documentation. The following are just a selection
645 of attribute files that are available.
646
647 .TP
648 .B md/sync_speed_min
649 This value, if set, overrides the system-wide setting in
650 .B /proc/sys/dev/raid/speed_limit_min
651 for this array only.
652 Writing the value
653 .B "system"
654 to this file will cause the system-wide setting to have effect.
655
656 .TP
657 .B md/sync_speed_max
658 This is the partner of
659 .B md/sync_speed_min
660 and overrides
661 .B /proc/sys/dev/raid/spool_limit_max
662 described below.
663
664 .TP
665 .B md/sync_action
666 This can be used to monitor and control the resync/recovery process of
667 MD.
668 In particular, writing "check" here will cause the array to read all
669 data block and check that they are consistent (e.g. parity is correct,
670 or all mirror replicas are the same). Any discrepancies found are
671 .B NOT
672 corrected.
673
674 A count of problems found will be stored in
675 .BR md/mismatch_count .
676
677 Alternately, "repair" can be written which will cause the same check
678 to be performed, but any errors will be corrected.
679
680 Finally, "idle" can be written to stop the check/repair process.
681
682 .TP
683 .B md/stripe_cache_size
684 This is only available on RAID5 and RAID6. It records the size (in
685 pages per device) of the stripe cache which is used for synchronising
686 all write operations to the array and all read operations if the array
687 is degraded. The default is 256. Valid values are 17 to 32768.
688 Increasing this number can increase performance in some situations, at
689 some cost in system memory. Note, setting this value too high can
690 result in an "out of memory" condition for the system.
691
692 memory_consumed = system_page_size * nr_disks * stripe_cache_size
693
694 .TP
695 .B md/preread_bypass_threshold
696 This is only available on RAID5 and RAID6. This variable sets the
697 number of times MD will service a full-stripe-write before servicing a
698 stripe that requires some "prereading". For fairness this defaults to
699 1. Valid values are 0 to stripe_cache_size. Setting this to 0
700 maximizes sequential-write throughput at the cost of fairness to threads
701 doing small or random writes.
702
703 .SS KERNEL PARAMETERS
704
705 The md driver recognised several different kernel parameters.
706 .TP
707 .B raid=noautodetect
708 This will disable the normal detection of md arrays that happens at
709 boot time. If a drive is partitioned with MS-DOS style partitions,
710 then if any of the 4 main partitions has a partition type of 0xFD,
711 then that partition will normally be inspected to see if it is part of
712 an MD array, and if any full arrays are found, they are started. This
713 kernel parameter disables this behaviour.
714
715 .TP
716 .B raid=partitionable
717 .TP
718 .B raid=part
719 These are available in 2.6 and later kernels only. They indicate that
720 autodetected MD arrays should be created as partitionable arrays, with
721 a different major device number to the original non-partitionable md
722 arrays. The device number is listed as
723 .I mdp
724 in
725 .IR /proc/devices .
726
727 .TP
728 .B md_mod.start_ro=1
729 .TP
730 .B /sys/module/md_mod/parameters/start_ro
731 This tells md to start all arrays in read-only mode. This is a soft
732 read-only that will automatically switch to read-write on the first
733 write request. However until that write request, nothing is written
734 to any device by md, and in particular, no resync or recovery
735 operation is started.
736
737 .TP
738 .B md_mod.start_dirty_degraded=1
739 .TP
740 .B /sys/module/md_mod/parameters/start_dirty_degraded
741 As mentioned above, md will not normally start a RAID4, RAID5, or
742 RAID6 that is both dirty and degraded as this situation can imply
743 hidden data loss. This can be awkward if the root filesystem is
744 affected. Using this module parameter allows such arrays to be started
745 at boot time. It should be understood that there is a real (though
746 small) risk of data corruption in this situation.
747
748 .TP
749 .BI md= n , dev , dev ,...
750 .TP
751 .BI md=d n , dev , dev ,...
752 This tells the md driver to assemble
753 .B /dev/md n
754 from the listed devices. It is only necessary to start the device
755 holding the root filesystem this way. Other arrays are best started
756 once the system is booted.
757
758 In 2.6 kernels, the
759 .B d
760 immediately after the
761 .B =
762 indicates that a partitionable device (e.g.
763 .BR /dev/md/d0 )
764 should be created rather than the original non-partitionable device.
765
766 .TP
767 .BI md= n , l , c , i , dev...
768 This tells the md driver to assemble a legacy RAID0 or LINEAR array
769 without a superblock.
770 .I n
771 gives the md device number,
772 .I l
773 gives the level, 0 for RAID0 or -1 for LINEAR,
774 .I c
775 gives the chunk size as a base-2 logarithm offset by twelve, so 0
776 means 4K, 1 means 8K.
777 .I i
778 is ignored (legacy support).
779
780 .SH FILES
781 .TP
782 .B /proc/mdstat
783 Contains information about the status of currently running array.
784 .TP
785 .B /proc/sys/dev/raid/speed_limit_min
786 A readable and writable file that reflects the current "goal" rebuild
787 speed for times when non-rebuild activity is current on an array.
788 The speed is in Kibibytes per second, and is a per-device rate, not a
789 per-array rate (which means that an array with more disks will shuffle
790 more data for a given speed). The default is 1000.
791
792 .TP
793 .B /proc/sys/dev/raid/speed_limit_max
794 A readable and writable file that reflects the current "goal" rebuild
795 speed for times when no non-rebuild activity is current on an array.
796 The default is 200,000.
797
798 .SH SEE ALSO
799 .BR mdadm (8),
800 .BR mkraid (8).