8d32a3f9 1CHANGES - 2.3b6 - 2018-11-08
050d2657 2============================
d07cb8d5 3
39897200
MS
4Changes in CUPS v2.3b6
5----------------------
6
08eac601 7- Localization update (Issue #5339, Issue #5348, Issue #5362, Issue #5408)
a2c43163 8- Documentation updates (Issue #5369)
997b6734
MS
9- The lpadmin command would create a non-working printer in some error cases
10 (Issue #5305)
9dcb503f
MS
11- The scheduler would crash if an empty `AccessLog` directive was specified
12 (Issue #5309)
9fc5c8d4 13- The scheduler did not idle-exit on some Linux distributions (Issue #5319)
1d677f11
MS
14- Fixed a regression in the changes to ippValidateAttribute (Issue #5322,
15 Issue #5330)
7e041a5e 16- Fixed a crash bug in the Epson dot matrix driver (Issue #5323)
945c83b9 17- Automatic debug logging of job errors did not work with systemd (Issue #5337)
553f29c9 18- The web interface did not list the IPP Everywhere "driver" (Issue #5338)
91505c0a
MS
19- The scheduler did not report all of the supported job options and values
20 (Issue #5340)
bf86060f
MS
21- The IPP Everywhere "driver" now properly supports face-up printers
22 (Issue #5345)
c604931d 23- Fixed some typos in the label printer drivers (Issue #5350)
8d32a3f9
MS
24- Setting the `Community` name to the empty string in `snmp.conf` now disables
25 SNMP supply level monitoring by all the standard network backends
26 (Issue #5354)
72a21348
MS
27- Multi-file jobs could get stuck if the backend failed (Issue #5359,
28 Issue #5413)
fd7190c1
MS
29- The IPP Everywhere "driver" no longer does local filtering when printing to
30 a shared CUPS printer (Issue #5361)
1582479c
MS
31- The lpadmin command now correctly reports IPP errors when configuring an
32 IPP Everywhere printer (Issue #5370)
3416fe95 33- Fixed some memory leaks discovered by Coverity (Issue #5375)
60478321 34- The PPD compiler incorrectly terminated JCL options (Issue #5379)
bac967ae
MS
35- The cupstestppd utility did not generate errors for missing/mismatched
36 CloseUI/JCLCloseUI keywords (Issue #5381)
cdeee633 37- The scheduler now reports the actual location of the log file (Issue #5398)
08761c26 38- Added a USB quirk rule (Issue #5420)
bbe495b0
MS
39- The scheduler was being backgrounded on macOS, causing applications to spin
40 (rdar://40436080)
7d4510a0
MS
41- The scheduler did not validate that required initial request attributes were
42 in the operation group (rdar://41098178)
bf265b3a 43- Authentication in the web interface did not work on macOS (rdar://41444473)
3aeb120e 44- Fixed an issue with HTTP Digest authentication (rdar://41709086)
59a8560a 45- The scheduler could crash when job history was purged (rdar://42198057)
39897200 46- Fixed a memory leak for some IPP (extension) syntaxes.
14435106
MS
47- The `cupscgi`, `cupsmime`, and `cupsppdc` support libraries are no longer
48 installed as shared libraries.
39897200
MS
49
50
8eed4387 51Changes in CUPS v2.3b5
39897200 52----------------------
d07cb8d5
MS
53
54- The `ipptool` program no longer checks for duplicate attributes when running
55 in list or CSV mode (Issue #5278)
159e0279
MS
56- The `cupsCreateJob`, `cupsPrintFile2`, and `cupsPrintFiles2` APIs did not use
57 the supplied HTTP connection (Issue #5288)
656c109a
MS
58- Fixed another crash in the scheduler when adding an IPP Everywhere printer
59 (Issue #5290)
4feb1fe2
MS
60- Added a workaround for certain web browsers that do not support multiple
61 authentication schemes in a single response header (Issue #5289)
0873f681 62- Fixed policy limits containing the `All` operation (Issue #5296)
bd4b5b3e 63- The scheduler was always restarted after idle-exit with systemd (Issue #5297)
050d2657 64- Added a USB quirks rule for the HP LaserJet P1102 (Issue #5310)
2de7c5f8 65- The mailto notifier did not wait for the welcome message (Issue #5312)
0541a2c9 66- Fixed a parsing bug in the pstops filter (Issue #5321)
dfe5f3b9 67- Documentation updates (Issue #5299, Issue #5301, Issue #5306)
b27f4108 68- Localization updates (Issue #5317)
53f84044
MS
69- The scheduler allowed environment variables to be specified in the
70 `cupsd.conf` file (rdar://37836779, rdar://37836995, rdar://37837252,
71 rdar://37837581)
fbcc927d
MS
72- Fax queues did not support pause (p) or wait-for-dialtone (w) characters
73 (rdar://39212256)
be7581b6
MS
74- The scheduler did not validate notify-recipient-uri values properly
75 (rdar://40068936)
8eed4387 76- The IPP parser allowed invalid group tags (rdar://40442124)
44cb0dd2 77- Fixed a parsing bug in the new authentication code.
d07cb8d5 78
2a20b512 79
63f8dcbd
MS
80Changes in CUPS v2.3b4
81----------------------
ab89234d 82
b25f3cf0 83- NOTICE: Printer drivers are now deprecated (Issue #5270)
0fea1812
MS
84- Kerberized printing to another CUPS server did not work correctly
85 (Issue #5233)
e6062e8e 86- Fixed printing to some IPP Everywhere printers (Issue #5238)
ab89234d 87- Fixed installation of filters (Issue #5247)
19186c8b
MS
88- The scheduler now supports using temporary print queues for older IPP/1.1
89 print queues like those shared by CUPS 1.3 and earlier (Issue #5241)
c6dbbca1
MS
90- Star Micronics printers need the "unidir" USB quirk rule (Issue #5251)
91- Documentation fixes (Issue #5252)
3cd7b5e0 92- Fixed a compile issue when PAM is not available (Issue #5253)
c6dbbca1
MS
93- Label printers supported by the rastertolabel driver don't support SNMP, so
94 don't delay printing to test it (Issue #5256)
ca75cc13 95- The scheduler could crash while adding an IPP Everywhere printer (Issue #5258)
c6dbbca1
MS
96- The Lexmark Optra E310 printer needs the "no-reattach" USB quirk rule
97 (Issue #5259)
0dfe6990
MS
98- Systemd did not restart cupsd when configuration changes were made that
99 required a restart (Issue #5263)
8aecb229
MS
100- The IPP Everywhere PPD generator did not include the `cupsJobPassword`
101 keyword, when supported (Issue #5265)
6a76f435 102- Fixed an Avahi crash bug in the scheduler (Issue #5268)
003c1790 103- Raw print queues are now deprecated (Issue #5269)
b056061b 104- Fixed an RPM packaging problem (Issue #5276)
fe1a4305 105- The IPP backend did not properly detect failed PDF prints (rdar://34055474)
eb61cb5b 106- TLS connections now properly timeout (rdar://34938533)
0bb02bfa
MS
107- Temp files could not be created in some sandboxed applications
108 (rdar://37789645)
c64170e5
MS
109- The ipptool `--ippserver` option did not encode out-of-band attributes
110 correctly.
c65e1c4f
MS
111- Added public `cupsEncodeOption` API for encoding a single option as an IPP
112 attribute.
0fb02fb9
MS
113- Removed support for the `-D_PPD_DEPRECATED=""` developer cheat - the PPD API
114 should no longer be used.
115- Removed support for `-D_IPP_PRIVATE_STRUCTURES=1` developer cheat - the IPP
116 accessor functions should be used instead.
ab89234d
MS
117
118
c283f46d
MS
119Changes in CUPS v2.3b3
120----------------------
121
f6e7a0c5 122- More fixes for printing to old CUPS servers (Issue #5211)
c283f46d
MS
123- The IPP Everywhere PPD generator did not support deep grayscale or 8-bit per
124 component AdobeRGB (Issue #5227)
092db1e2
MS
125- Additional changes for the scheduler to substitute default values for invalid
126 job attributes when running in "relaxed conformance" mode (Issue #5229)
f6e7a0c5 127- Localization changes (Issue #5232, rdar://37068158)
22974c5f
MS
128- The `cupsCopyDestInfo` function did not work with all print queues
129 (Issue #5235)
c283f46d 130
bea37134 131
e1613057
MS
132Changes in CUPS v2.3b2
133----------------------
134
ead6e488
MS
135- Localization changes (Issue #5210)
136- Build fixes (Issue #5217)
a8b28f18 137- IPP Everywhere PPDs were not localized to English (Issue #5205)
625bb9de
MS
138- The `cupsGetDests` and `cupsEnumDests` functions no longer filter out local
139 print services like IPP USB devices (Issue #5206)
3145b7e6
MS
140- The `cupsCopyDest` function now correctly copies the `is_default` value
141 (Issue #5208)
6a3d63e6 142- Printing to old CUPS servers has been fixed (Issue #5211)
e1613057 143- The `ppdInstallableConflict` tested too many constraints (Issue #5213)
378eeedf
MS
144- All HTTP field values can now be longer than `HTTP_MAX_VALUE` bytes
145 (Issue #5216)
43bcc47b 146- Added a USB quirk rule for Canon MP280 series printers (Issue #5221)
7c91db71
MS
147- The `cupsRasterWritePixels` function did not correctly swap bytes for some
148 formats (Issue #5225)
117bf0d1 149- Fixed an issue with mapping finishing options (rdar://34250727)
4ef3ee37
MS
150- The `ppdLocalizeIPPReason` function incorrectly returned a localized version
151 of "none" (rdar://36566269)
c4faa907
MS
152- The scheduler did not add ".local" to the default DNS-SD host name when
153 needed.
e1613057
MS
154
155
11143dcf 156Changes in CUPS v2.3b1
bea37134
MS
157----------------------
158
e3101897 159- CUPS is now provided under the Apache License, Version 2.0.
67091b1b 160- Documentation updates (Issue #4580, Issue #5177, Issue #5192)
336b669e
MS
161- The `cupsCopyDestConflicts` function now handles collection attribute
162 ("media-col", "finishings-col", etc.) constraints (Issue #4096)
42a5ae2a 163- The `lpoptions` command incorrectly saved default options (Issue #4717)
d6db9ea1 164- The `lpstat` command now reports when new jobs are being held (Issue #4761)
d5621649
MS
165- The `ippfind` command now supports finding printers whose name starts with an
166 underscore (Issue #4833)
7ec11630
MS
167- The CUPS library now supports the latest HTTP Digest authentication
168 specification including support for SHA-256 (Issue #4862)
409f5497 169- The scheduler now supports the "printer-id" attribute (Issue #4868)
f1547f12
MS
170- No longer support backslash, question mark, or quotes in printer names
171 (Issue #4966)
3d468ced
MS
172- The scheduler no longer logs pages as they are printed, instead just logging
173 a total of the pages printed at job completion (Issue #4991)
b00c8409 174- Dropped RSS subscription management from the web interface (Issue #5012)
c5d2b233
MS
175- Bonjour printer sharing now uses the DNS-SD hostname (or ServerName value if
176 none is defined) when registering shared printers on the network (Issue #5071)
6646208b
MS
177- The `ipptool` command now supports writing `ippserver` attributes files
178 (Issue #5093)
d6db9ea1
MS
179- The `lp` and `lpr` commands now provide better error messages when the default
180 printer cannot be found (Issue #5096)
181- The `lpadmin` command now provides a better error message when an unsupported
d0df9cd3 182 System V interface script is used (Issue #5111)
eb2cb9b0
MS
183- The scheduler did not write out dirty configuration and state files if there
184 were open client connections (Issue #5118)
8f1fbdec
MS
185- The `SSLOptions` directive now supports `MinTLS` and `MaxTLS` options to
186 control the minimum and maximum TLS versions that will be allowed,
187 respectively (Issue #5119)
b00c8409 188- Dropped hard-coded CGI scripting language support (Issue #5124)
c5f5c5a7
MS
189- The `cupsEnumDests` function did not include options from the lpoptions
190 files (Issue #5144)
d6db9ea1 191- Fixed the `ippserver` sample code when threading is disabled or unavailable
98491ecc 192 (Issue #5154)
0e743fdf
MS
193- Added label markup to checkbox and radio button controls in the web interface
194 templates (Issue #5161)
da9ffe23 195- Fixed group validation on OpenBSD (Issue #5166)
71dc43af
MS
196- Improved IPP Everywhere media support, including a new
197 `cupsAddDestMediaOptions` function (Issue #5167)
89550f3f
MS
198- IPP Everywhere PPDs now include localizations of printer-specific media types,
199 when available (Issue #5168)
7f9a23b9
MS
200- The cups-driverd program incorrectly stopped scanning PPDs as soon as a loop
201 was seen (Issue #5170)
cfa8aa69 202- IPP Everywhere PPDs now support IPP job presets (Issue #5179)
4f63d6cd 203- IPP Everywhere PPDs now support finishing templates (Issue #5180)
7e382613 204- Fixed a journald support bug in the scheduler (Issue #5181)
ac05c630
MS
205- Fixed PAM module detection and added support for the common PAM definitions
206 (Issue #5185)
6d14c1bb
MS
207- The scheduler now substitutes default values for invalid job attributes when
208 running in "relaxed conformance" mode (Issue #5186)
9e44dfbe 209- The scheduler did not work with older versions of uClibc (Issue #5188)
2fa1ba3c
MS
210- The scheduler now generates a strings file for localizing PPD options
211 (Issue #5194)