]> git.ipfire.org Git - thirdparty/mdadm.git/blame_incremental - mdadm.8
RebuildMap: handle missing disks
[thirdparty/mdadm.git] / mdadm.8
... / ...
CommitLineData
1.\" -*- nroff -*-
2.\" Copyright Neil Brown and others.
3.\" This program is free software; you can redistribute it and/or modify
4.\" it under the terms of the GNU General Public License as published by
5.\" the Free Software Foundation; either version 2 of the License, or
6.\" (at your option) any later version.
7.\" See file COPYING in distribution for details.
8.TH MDADM 8 "" v3.0-devel3
9.SH NAME
10mdadm \- manage MD devices
11.I aka
12Linux Software RAID
13
14.SH SYNOPSIS
15
16.BI mdadm " [mode] <raiddevice> [options] <component-devices>"
17
18.SH DESCRIPTION
19RAID devices are virtual devices created from two or more
20real block devices. This allows multiple devices (typically disk
21drives or partitions thereof) to be combined into a single device to
22hold (for example) a single filesystem.
23Some RAID levels include redundancy and so can survive some degree of
24device failure.
25
26Linux Software RAID devices are implemented through the md (Multiple
27Devices) device driver.
28
29Currently, Linux supports
30.B LINEAR
31md devices,
32.B RAID0
33(striping),
34.B RAID1
35(mirroring),
36.BR RAID4 ,
37.BR RAID5 ,
38.BR RAID6 ,
39.BR RAID10 ,
40.BR MULTIPATH ,
41.BR FAULTY ,
42and
43.BR CONTAINER .
44
45.B MULTIPATH
46is not a Software RAID mechanism, but does involve
47multiple devices:
48each device is a path to one common physical storage device.
49
50.B FAULTY
51is also not true RAID, and it only involves one device. It
52provides a layer over a true device that can be used to inject faults.
53
54.B CONTAINER
55is different again. A
56.B CONTAINER
57is a collection of devices that are
58managed as a set. This is similar to the set of devices connected to
59a hardware RAID controller. The set of devices may contain a number
60of different RAID arrays each utilising some (or all) blocks from a
61number of the devices in the set. For example, two devices in a 5-device set
62might form a RAID1 used the whole devices. The remaining three might
63have a RAID5 over the first half of each device, and a RAID0 over the
64second half.
65
66With a
67.BR CONTAINER ,
68there is one set of metadata that describes all of
69the arrays in the container. So when
70.I mdadm
71creates a
72.B CONTAINER
73device, it just represents the metadata. Other normal arrays (RAID1
74etc) can be created inside that container.
75
76
77.\".I mdadm
78.\"is a program that can be used to create, manage, and monitor
79.\"MD devices. As
80.\"such it provides a similar set of functionality to the
81.\".B raidtools
82.\"packages.
83.\"The key differences between
84.\".I mdadm
85.\"and
86.\".B raidtools
87.\"are:
88.\".IP \(bu 4
89.\".I mdadm
90.\"is a single program and not a collection of programs.
91.\".IP \(bu 4
92.\".I mdadm
93.\"can perform (almost) all of its functions without having a
94.\"configuration file and does not use one by default. Also
95.\".I mdadm
96.\"helps with management of the configuration
97.\"file.
98.\".IP \(bu 4
99.\".I mdadm
100.\"can provide information about your arrays (through Query, Detail, and Examine)
101.\"that
102.\".B raidtools
103.\"cannot.
104.\".P
105.\".I mdadm
106.\"does not use
107.\".IR /etc/raidtab ,
108.\"the
109.\".B raidtools
110.\"configuration file, at all. It has a different configuration file
111.\"with a different format and a different purpose.
112
113.SH MODES
114mdadm has several major modes of operation:
115.TP
116.B Assemble
117Assemble the components of a previously created
118array into an active array. Components can be explicitly given
119or can be searched for.
120.I mdadm
121checks that the components
122do form a bona fide array, and can, on request, fiddle superblock
123information so as to assemble a faulty array.
124
125.TP
126.B Build
127Build an array that doesn't have per-device superblocks. For these
128sorts of arrays,
129.I mdadm
130cannot differentiate between initial creation and subsequent assembly
131of an array. It also cannot perform any checks that appropriate
132components have been requested. Because of this, the
133.B Build
134mode should only be used together with a complete understanding of
135what you are doing.
136
137.TP
138.B Create
139Create a new array with per-device superblocks.
140.\"It can progress
141.\"in several step create-add-add-run or it can all happen with one command.
142
143.TP
144.B "Follow or Monitor"
145Monitor one or more md devices and act on any state changes. This is
146only meaningful for raid1, 4, 5, 6, 10 or multipath arrays, as
147only these have interesting state. raid0 or linear never have
148missing, spare, or failed drives, so there is nothing to monitor.
149
150.TP
151.B "Grow"
152Grow (or shrink) an array, or otherwise reshape it in some way.
153Currently supported growth options including changing the active size
154of component devices and changing the number of active devices in RAID
155levels 1/4/5/6, as well as adding or removing a write-intent bitmap.
156
157.TP
158.B "Incremental Assembly"
159Add a single device to an appropriate array. If the addition of the
160device makes the array runnable, the array will be started.
161This provides a convenient interface to a
162.I hot-plug
163system. As each device is detected,
164.I mdadm
165has a chance to include it in some array as appropriate.
166.P
167If a
168.B CONTAINER
169is passed to
170.I mdadm
171in this mode, then any arrays within that container will be assembled
172and started.
173
174.TP
175.B Manage
176This is for doing things to specific components of an array such as
177adding new spares and removing faulty devices.
178
179.TP
180.B Misc
181This is an 'everything else' mode that supports operations on active
182arrays, operations on component devices such as erasing old superblocks, and
183information gathering operations.
184.\"This mode allows operations on independent devices such as examine MD
185.\"superblocks, erasing old superblocks and stopping active arrays.
186
187.TP
188.B Auto-detect
189This mode does not act on a specific device or array, but rather it
190requests the Linux Kernel to activate any auto-detected arrays.
191.SH OPTIONS
192
193.SH Options for selecting a mode are:
194
195.TP
196.BR \-A ", " \-\-assemble
197Assemble a pre-existing array.
198
199.TP
200.BR \-B ", " \-\-build
201Build a legacy array without superblocks.
202
203.TP
204.BR \-C ", " \-\-create
205Create a new array.
206
207.TP
208.BR \-F ", " \-\-follow ", " \-\-monitor
209Select
210.B Monitor
211mode.
212
213.TP
214.BR \-G ", " \-\-grow
215Change the size or shape of an active array.
216
217.TP
218.BR \-I ", " \-\-incremental
219Add a single device into an appropriate array, and possibly start the array.
220
221.TP
222.B \-\-auto-detect
223Request that the kernel starts any auto-detected arrays. This can only
224work if
225.I md
226is compiled into the kernel \(em not if it is a module.
227Arrays can be auto-detected by the kernel if all the components are in
228primary MS-DOS partitions with partition type
229.BR FD .
230In-kernel autodetect is not recommended for new installations. Using
231.I mdadm
232to detect and assemble arrays \(em possibly in an
233.I initrd
234\(em is substantially more flexible and should be preferred.
235
236.P
237If a device is given before any options, or if the first option is
238.BR \-\-add ,
239.BR \-\-fail ,
240or
241.BR \-\-remove ,
242then the MANAGE mode is assume.
243Anything other than these will cause the
244.B Misc
245mode to be assumed.
246
247.SH Options that are not mode-specific are:
248
249.TP
250.BR \-h ", " \-\-help
251Display general help message or, after one of the above options, a
252mode-specific help message.
253
254.TP
255.B \-\-help\-options
256Display more detailed help about command line parsing and some commonly
257used options.
258
259.TP
260.BR \-V ", " \-\-version
261Print version information for mdadm.
262
263.TP
264.BR \-v ", " \-\-verbose
265Be more verbose about what is happening. This can be used twice to be
266extra-verbose.
267The extra verbosity currently only affects
268.B \-\-detail \-\-scan
269and
270.BR "\-\-examine \-\-scan" .
271
272.TP
273.BR \-q ", " \-\-quiet
274Avoid printing purely informative messages. With this,
275.I mdadm
276will be silent unless there is something really important to report.
277
278.TP
279.BR \-b ", " \-\-brief
280Be less verbose. This is used with
281.B \-\-detail
282and
283.BR \-\-examine .
284Using
285.B \-\-brief
286with
287.B \-\-verbose
288gives an intermediate level of verbosity.
289
290.TP
291.BR \-f ", " \-\-force
292Be more forceful about certain operations. See the various modes for
293the exact meaning of this option in different contexts.
294
295.TP
296.BR \-c ", " \-\-config=
297Specify the config file. Default is to use
298.BR /etc/mdadm.conf ,
299or if that is missing then
300.BR /etc/mdadm/mdadm.conf .
301If the config file given is
302.B "partitions"
303then nothing will be read, but
304.I mdadm
305will act as though the config file contained exactly
306.B "DEVICE partitions containers"
307and will read
308.B /proc/partitions
309to find a list of devices to scan, and
310.B /proc/mdstat
311to find a list of containers to examine.
312If the word
313.B "none"
314is given for the config file, then
315.I mdadm
316will act as though the config file were empty.
317
318.TP
319.BR \-s ", " \-\-scan
320Scan config file or
321.B /proc/mdstat
322for missing information.
323In general, this option gives
324.I mdadm
325permission to get any missing information (like component devices,
326array devices, array identities, and alert destination) from the
327configuration file (see previous option);
328one exception is MISC mode when using
329.B \-\-detail
330or
331.B \-\-stop,
332in which case
333.B \-\-scan
334says to get a list of array devices from
335.BR /proc/mdstat .
336
337.TP
338.B \-e ", " \-\-metadata=
339Declare the style of superblock (raid metadata) to be used. The
340default is 0.90 for
341.BR \-\-create ,
342and to guess for other operations.
343The default can be overridden by setting the
344.B metadata
345value for the
346.B CREATE
347keyword in
348.BR mdadm.conf .
349
350Options are:
351.RS
352.IP "0, 0.90, default"
353Use the original 0.90 format superblock. This format limits arrays to
35428 component devices and limits component devices of levels 1 and
355greater to 2 terabytes.
356.IP "1, 1.0, 1.1, 1.2"
357Use the new version-1 format superblock. This has few restrictions.
358The different sub-versions store the superblock at different locations
359on the device, either at the end (for 1.0), at the start (for 1.1) or
3604K from the start (for 1.2).
361.IP ddf
362Use the "Industry Standard" DDF (Disk Data Format) format. When
363creating a DDF array a
364.B CONTAINER
365will be created, and normal arrays can be created in that container.
366.IP imsm
367Use the Intel(R) Matrix Storage Manager metadata format. This creates a
368.B CONTAINER
369which is managed in a similar manner to DDF, and is supported by an
370option-rom on some platforms:
371.IP
372.B http://www.intel.com/design/chipsets/matrixstorage_sb.htm
373.PP
374.RE
375
376.TP
377.B \-\-homehost=
378This will override any
379.B HOMEHOST
380setting in the config file and provides the identity of the host which
381should be considered the home for any arrays.
382
383When creating an array, the
384.B homehost
385will be recorded in the superblock. For version-1 superblocks, it will
386be prefixed to the array name. For version-0.90 superblocks, part of
387the SHA1 hash of the hostname will be stored in the later half of the
388UUID.
389
390When reporting information about an array, any array which is tagged
391for the given homehost will be reported as such.
392
393When using Auto-Assemble, only arrays tagged for the given homehost
394will be assembled.
395
396.SH For create, build, or grow:
397
398.TP
399.BR \-n ", " \-\-raid\-devices=
400Specify the number of active devices in the array. This, plus the
401number of spare devices (see below) must equal the number of
402.I component-devices
403(including "\fBmissing\fP" devices)
404that are listed on the command line for
405.BR \-\-create .
406Setting a value of 1 is probably
407a mistake and so requires that
408.B \-\-force
409be specified first. A value of 1 will then be allowed for linear,
410multipath, raid0 and raid1. It is never allowed for raid4 or raid5.
411.br
412This number can only be changed using
413.B \-\-grow
414for RAID1, RAID5 and RAID6 arrays, and only on kernels which provide
415necessary support.
416
417.TP
418.BR \-x ", " \-\-spare\-devices=
419Specify the number of spare (eXtra) devices in the initial array.
420Spares can also be added
421and removed later. The number of component devices listed
422on the command line must equal the number of raid devices plus the
423number of spare devices.
424
425
426.TP
427.BR \-z ", " \-\-size=
428Amount (in Kibibytes) of space to use from each drive in RAID level 1/4/5/6.
429This must be a multiple of the chunk size, and must leave about 128Kb
430of space at the end of the drive for the RAID superblock.
431If this is not specified
432(as it normally is not) the smallest drive (or partition) sets the
433size, though if there is a variance among the drives of greater than 1%, a warning is
434issued.
435
436This value can be set with
437.B \-\-grow
438for RAID level 1/4/5/6. If the array was created with a size smaller
439than the currently active drives, the extra space can be accessed
440using
441.BR \-\-grow .
442The size can be given as
443.B max
444which means to choose the largest size that fits on all current drives.
445
446This value can not be used with
447.B CONTAINER
448metadata such as DDF and IMSM.
449
450.TP
451.BR \-c ", " \-\-chunk=
452Specify chunk size of kibibytes. The default is 64.
453
454.TP
455.BR \-\-rounding=
456Specify rounding factor for linear array (==chunk size)
457
458.TP
459.BR \-l ", " \-\-level=
460Set raid level. When used with
461.BR \-\-create ,
462options are: linear, raid0, 0, stripe, raid1, 1, mirror, raid4, 4,
463raid5, 5, raid6, 6, raid10, 10, multipath, mp, faulty, container.
464Obviously some of these are synonymous.
465
466When a
467.B CONTAINER
468metadata type is requested, only the
469.B container
470level is permitted, and it does not need to be explicitly given.
471
472When used with
473.BR \-\-build ,
474only linear, stripe, raid0, 0, raid1, multipath, mp, and faulty are valid.
475
476Not yet supported with
477.BR \-\-grow .
478
479.TP
480.BR \-p ", " \-\-layout=
481This option configures the fine details of data layout for raid5,
482and raid10 arrays, and controls the failure modes for
483.IR faulty .
484
485The layout of the raid5 parity block can be one of
486.BR left\-asymmetric ,
487.BR left\-symmetric ,
488.BR right\-asymmetric ,
489.BR right\-symmetric ,
490.BR la ", " ra ", " ls ", " rs .
491The default is
492.BR left\-symmetric .
493
494When setting the failure mode for level
495.I faulty,
496the options are:
497.BR write\-transient ", " wt ,
498.BR read\-transient ", " rt ,
499.BR write\-persistent ", " wp ,
500.BR read\-persistent ", " rp ,
501.BR write\-all ,
502.BR read\-fixable ", " rf ,
503.BR clear ", " flush ", " none .
504
505Each failure mode can be followed by a number, which is used as a period
506between fault generation. Without a number, the fault is generated
507once on the first relevant request. With a number, the fault will be
508generated after that many requests, and will continue to be generated
509every time the period elapses.
510
511Multiple failure modes can be current simultaneously by using the
512.B \-\-grow
513option to set subsequent failure modes.
514
515"clear" or "none" will remove any pending or periodic failure modes,
516and "flush" will clear any persistent faults.
517
518To set the parity with
519.BR \-\-grow ,
520the level of the array ("faulty")
521must be specified before the fault mode is specified.
522
523Finally, the layout options for RAID10 are one of 'n', 'o' or 'f' followed
524by a small number. The default is 'n2'. The supported options are:
525
526.I 'n'
527signals 'near' copies. Multiple copies of one data block are at
528similar offsets in different devices.
529
530.I 'o'
531signals 'offset' copies. Rather than the chunks being duplicated
532within a stripe, whole stripes are duplicated but are rotated by one
533device so duplicate blocks are on different devices. Thus subsequent
534copies of a block are in the next drive, and are one chunk further
535down.
536
537.I 'f'
538signals 'far' copies
539(multiple copies have very different offsets).
540See md(4) for more detail about 'near' and 'far'.
541
542The number is the number of copies of each datablock. 2 is normal, 3
543can be useful. This number can be at most equal to the number of
544devices in the array. It does not need to divide evenly into that
545number (e.g. it is perfectly legal to have an 'n2' layout for an array
546with an odd number of devices).
547
548.TP
549.BR \-\-parity=
550same as
551.B \-\-layout
552(thus explaining the p of
553.BR \-p ).
554
555.TP
556.BR \-b ", " \-\-bitmap=
557Specify a file to store a write-intent bitmap in. The file should not
558exist unless
559.B \-\-force
560is also given. The same file should be provided
561when assembling the array. If the word
562.B "internal"
563is given, then the bitmap is stored with the metadata on the array,
564and so is replicated on all devices. If the word
565.B "none"
566is given with
567.B \-\-grow
568mode, then any bitmap that is present is removed.
569
570To help catch typing errors, the filename must contain at least one
571slash ('/') if it is a real file (not 'internal' or 'none').
572
573Note: external bitmaps are only known to work on ext2 and ext3.
574Storing bitmap files on other filesystems may result in serious problems.
575
576.TP
577.BR \-\-bitmap\-chunk=
578Set the chunksize of the bitmap. Each bit corresponds to that many
579Kilobytes of storage.
580When using a file based bitmap, the default is to use the smallest
581size that is at-least 4 and requires no more than 2^21 chunks.
582When using an
583.B internal
584bitmap, the chunksize is automatically determined to make best use of
585available space.
586
587
588.TP
589.BR \-W ", " \-\-write\-mostly
590subsequent devices lists in a
591.BR \-\-build ,
592.BR \-\-create ,
593or
594.B \-\-add
595command will be flagged as 'write-mostly'. This is valid for RAID1
596only and means that the 'md' driver will avoid reading from these
597devices if at all possible. This can be useful if mirroring over a
598slow link.
599
600.TP
601.BR \-\-write\-behind=
602Specify that write-behind mode should be enabled (valid for RAID1
603only). If an argument is specified, it will set the maximum number
604of outstanding writes allowed. The default value is 256.
605A write-intent bitmap is required in order to use write-behind
606mode, and write-behind is only attempted on drives marked as
607.IR write-mostly .
608
609.TP
610.BR \-\-assume\-clean
611Tell
612.I mdadm
613that the array pre-existed and is known to be clean. It can be useful
614when trying to recover from a major failure as you can be sure that no
615data will be affected unless you actually write to the array. It can
616also be used when creating a RAID1 or RAID10 if you want to avoid the
617initial resync, however this practice \(em while normally safe \(em is not
618recommended. Use this only if you really know what you are doing.
619
620.TP
621.BR \-\-backup\-file=
622This is needed when
623.B \-\-grow
624is used to increase the number of
625raid-devices in a RAID5 if there are no spare devices available.
626See the section below on RAID_DEVICE CHANGES. The file should be
627stored on a separate device, not on the raid array being reshaped.
628
629.TP
630.BR \-N ", " \-\-name=
631Set a
632.B name
633for the array. This is currently only effective when creating an
634array with a version-1 superblock. The name is a simple textual
635string that can be used to identify array components when assembling.
636
637.TP
638.BR \-R ", " \-\-run
639Insist that
640.I mdadm
641run the array, even if some of the components
642appear to be active in another array or filesystem. Normally
643.I mdadm
644will ask for confirmation before including such components in an
645array. This option causes that question to be suppressed.
646
647.TP
648.BR \-f ", " \-\-force
649Insist that
650.I mdadm
651accept the geometry and layout specified without question. Normally
652.I mdadm
653will not allow creation of an array with only one device, and will try
654to create a raid5 array with one missing drive (as this makes the
655initial resync work faster). With
656.BR \-\-force ,
657.I mdadm
658will not try to be so clever.
659
660.TP
661.BR \-a ", " "\-\-auto{=no,yes,md,mdp,part,p}{NN}"
662Instruct mdadm to create the device file if needed, possibly allocating
663an unused minor number. "md" causes a non-partitionable array
664to be used. "mdp", "part" or "p" causes a partitionable array (2.6 and
665later) to be used. "yes" requires the named md device to have
666a 'standard' format, and the type and minor number will be determined
667from this. See DEVICE NAMES below.
668
669The argument can also come immediately after
670"\-a". e.g. "\-ap".
671
672If
673.B \-\-auto
674is not given on the command line or in the config file, then
675the default will be
676.BR \-\-auto=yes .
677
678If
679.B \-\-scan
680is also given, then any
681.I auto=
682entries in the config file will override the
683.B \-\-auto
684instruction given on the command line.
685
686For partitionable arrays,
687.I mdadm
688will create the device file for the whole array and for the first 4
689partitions. A different number of partitions can be specified at the
690end of this option (e.g.
691.BR \-\-auto=p7 ).
692If the device name ends with a digit, the partition names add a 'p',
693and a number, e.g. "/dev/md/home1p3". If there is no
694trailing digit, then the partition names just have a number added,
695e.g. "/dev/md/scratch3".
696
697If the md device name is in a 'standard' format as described in DEVICE
698NAMES, then it will be created, if necessary, with the appropriate
699number based on that name. If the device name is not in one of these
700formats, then a unused minor number will be allocated. The minor
701number will be considered unused if there is no active array for that
702number, and there is no entry in /dev for that number and with a
703non-standard name. Name that are not in 'standard' format are only
704allowed in "/dev/md/".
705
706\".TP
707\".BR \-\-symlink = no
708\"Normally when
709\".B \-\-auto
710\"causes
711\".I mdadm
712\"to create devices in
713\".B /dev/md/
714\"it will also create symlinks from
715\".B /dev/
716\"with names starting with
717\".B md
718\"or
719\".BR md_ .
720\"Use
721\".B \-\-symlink=no
722\"to suppress this, or
723\".B \-\-symlink=yes
724\"to enforce this even if it is suppressing
725\".IR mdadm.conf .
726\"
727
728.SH For assemble:
729
730.TP
731.BR \-u ", " \-\-uuid=
732uuid of array to assemble. Devices which don't have this uuid are
733excluded
734
735.TP
736.BR \-m ", " \-\-super\-minor=
737Minor number of device that array was created for. Devices which
738don't have this minor number are excluded. If you create an array as
739/dev/md1, then all superblocks will contain the minor number 1, even if
740the array is later assembled as /dev/md2.
741
742Giving the literal word "dev" for
743.B \-\-super\-minor
744will cause
745.I mdadm
746to use the minor number of the md device that is being assembled.
747e.g. when assembling
748.BR /dev/md0 ,
749.B \-\-super\-minor=dev
750will look for super blocks with a minor number of 0.
751
752.TP
753.BR \-N ", " \-\-name=
754Specify the name of the array to assemble. This must be the name
755that was specified when creating the array. It must either match
756the name stored in the superblock exactly, or it must match
757with the current
758.I homehost
759prefixed to the start of the given name.
760
761.TP
762.BR \-f ", " \-\-force
763Assemble the array even if some superblocks appear out-of-date
764
765.TP
766.BR \-R ", " \-\-run
767Attempt to start the array even if fewer drives were given than were
768present last time the array was active. Normally if not all the
769expected drives are found and
770.B \-\-scan
771is not used, then the array will be assembled but not started.
772With
773.B \-\-run
774an attempt will be made to start it anyway.
775
776.TP
777.B \-\-no\-degraded
778This is the reverse of
779.B \-\-run
780in that it inhibits the startup of array unless all expected drives
781are present. This is only needed with
782.B \-\-scan,
783and can be used if the physical connections to devices are
784not as reliable as you would like.
785
786.TP
787.BR \-a ", " "\-\-auto{=no,yes,md,mdp,part}"
788See this option under Create and Build options.
789
790.TP
791.BR \-b ", " \-\-bitmap=
792Specify the bitmap file that was given when the array was created. If
793an array has an
794.B internal
795bitmap, there is no need to specify this when assembling the array.
796
797.TP
798.BR \-\-backup\-file=
799If
800.B \-\-backup\-file
801was used to grow the number of raid-devices in a RAID5, and the system
802crashed during the critical section, then the same
803.B \-\-backup\-file
804must be presented to
805.B \-\-assemble
806to allow possibly corrupted data to be restored.
807
808.TP
809.BR \-U ", " \-\-update=
810Update the superblock on each device while assembling the array. The
811argument given to this flag can be one of
812.BR sparc2.2 ,
813.BR summaries ,
814.BR uuid ,
815.BR name ,
816.BR homehost ,
817.BR resync ,
818.BR byteorder ,
819.BR devicesize ,
820or
821.BR super\-minor .
822
823The
824.B sparc2.2
825option will adjust the superblock of an array what was created on a Sparc
826machine running a patched 2.2 Linux kernel. This kernel got the
827alignment of part of the superblock wrong. You can use the
828.B "\-\-examine \-\-sparc2.2"
829option to
830.I mdadm
831to see what effect this would have.
832
833The
834.B super\-minor
835option will update the
836.B "preferred minor"
837field on each superblock to match the minor number of the array being
838assembled.
839This can be useful if
840.B \-\-examine
841reports a different "Preferred Minor" to
842.BR \-\-detail .
843In some cases this update will be performed automatically
844by the kernel driver. In particular the update happens automatically
845at the first write to an array with redundancy (RAID level 1 or
846greater) on a 2.6 (or later) kernel.
847
848The
849.B uuid
850option will change the uuid of the array. If a UUID is given with the
851.B \-\-uuid
852option that UUID will be used as a new UUID and will
853.B NOT
854be used to help identify the devices in the array.
855If no
856.B \-\-uuid
857is given, a random UUID is chosen.
858
859The
860.B name
861option will change the
862.I name
863of the array as stored in the superblock. This is only supported for
864version-1 superblocks.
865
866The
867.B homehost
868option will change the
869.I homehost
870as recorded in the superblock. For version-0 superblocks, this is the
871same as updating the UUID.
872For version-1 superblocks, this involves updating the name.
873
874The
875.B resync
876option will cause the array to be marked
877.I dirty
878meaning that any redundancy in the array (e.g. parity for raid5,
879copies for raid1) may be incorrect. This will cause the raid system
880to perform a "resync" pass to make sure that all redundant information
881is correct.
882
883The
884.B byteorder
885option allows arrays to be moved between machines with different
886byte-order.
887When assembling such an array for the first time after a move, giving
888.B "\-\-update=byteorder"
889will cause
890.I mdadm
891to expect superblocks to have their byteorder reversed, and will
892correct that order before assembling the array. This is only valid
893with original (Version 0.90) superblocks.
894
895The
896.B summaries
897option will correct the summaries in the superblock. That is the
898counts of total, working, active, failed, and spare devices.
899
900The
901.B devicesize
902will rarely be of use. It applies to version 1.1 and 1.2 metadata
903only (where the metadata is at the start of the device) and is only
904useful when the component device has changed size (typically become
905larger). The version 1 metadata records the amount of the device that
906can be used to store data, so if a device in a version 1.1 or 1.2
907array becomes larger, the metadata will still be visible, but the
908extra space will not. In this case it might be useful to assemble the
909array with
910.BR \-\-update=devicesize .
911This will cause
912.I mdadm
913to determine the maximum usable amount of space on each device and
914update the relevant field in the metadata.
915
916.TP
917.B \-\-auto\-update\-homehost
918This flag is only meaningful with auto-assembly (see discussion below).
919In that situation, if no suitable arrays are found for this homehost,
920.I mdadm
921will rescan for any arrays at all and will assemble them and update the
922homehost to match the current host.
923
924.SH For Manage mode:
925
926.TP
927.BR \-a ", " \-\-add
928hot-add listed devices.
929
930.TP
931.BR \-\-re\-add
932re-add a device that was recently removed from an array.
933
934.TP
935.BR \-r ", " \-\-remove
936remove listed devices. They must not be active. i.e. they should
937be failed or spare devices. As well as the name of a device file
938(e.g.
939.BR /dev/sda1 )
940the words
941.B failed
942and
943.B detached
944can be given to
945.BR \-\-remove .
946The first causes all failed device to be removed. The second causes
947any device which is no longer connected to the system (i.e an 'open'
948returns
949.BR ENXIO )
950to be removed. This will only succeed for devices that are spares or
951have already been marked as failed.
952
953.TP
954.BR \-f ", " \-\-fail
955mark listed devices as faulty.
956As well as the name of a device file, the word
957.B detached
958can be given. This will cause any device that has been detached from
959the system to be marked as failed. It can then be removed.
960
961.TP
962.BR \-\-set\-faulty
963same as
964.BR \-\-fail .
965
966.TP
967.BR \-\-write\-mostly
968Subsequent devices that are added or re-added will have the 'write-mostly'
969flag set. This is only valid for RAID! and means that the 'md' driver
970will avoid reading from these devices if possible.
971.TP
972.BR \-\-readwrite
973Subsequent devices that are added or re-added will have the 'write-mostly'
974flag cleared.
975
976
977.P
978Each of these options require that the first device listed is the array
979to be acted upon, and the remainder are component devices to be added,
980removed, or marked as faulty. Several different operations can be
981specified for different devices, e.g.
982.in +5
983mdadm /dev/md0 \-\-add /dev/sda1 \-\-fail /dev/sdb1 \-\-remove /dev/sdb1
984.in -5
985Each operation applies to all devices listed until the next
986operation.
987
988If an array is using a write-intent bitmap, then devices which have
989been removed can be re-added in a way that avoids a full
990reconstruction but instead just updates the blocks that have changed
991since the device was removed. For arrays with persistent metadata
992(superblocks) this is done automatically. For arrays created with
993.B \-\-build
994mdadm needs to be told that this device we removed recently with
995.BR \-\-re\-add .
996
997Devices can only be removed from an array if they are not in active
998use, i.e. that must be spares or failed devices. To remove an active
999device, it must first be marked as
1000.B faulty.
1001
1002.SH For Misc mode:
1003
1004.TP
1005.BR \-Q ", " \-\-query
1006Examine a device to see
1007(1) if it is an md device and (2) if it is a component of an md
1008array.
1009Information about what is discovered is presented.
1010
1011.TP
1012.BR \-D ", " \-\-detail
1013Print detail of one or more md devices.
1014
1015.TP
1016.BR \-\-detail\-platform
1017Print detail of the platform's raid capabilities (firmware / hardware
1018topology) for a given metadata format.
1019
1020.TP
1021.BR \-Y ", " \-\-export
1022When used with
1023.B \-\-detail
1024or
1025.BR \-\-examine ,
1026output will be formatted as
1027.B key=value
1028pairs for easy import into the environment.
1029
1030.TP
1031.BR \-E ", " \-\-examine
1032Print content of md superblock on device(s).
1033.TP
1034.B \-\-sparc2.2
1035If an array was created on a 2.2 Linux kernel patched with RAID
1036support, the superblock will have been created incorrectly, or at
1037least incompatibly with 2.4 and later kernels. Using the
1038.B \-\-sparc2.2
1039flag with
1040.B \-\-examine
1041will fix the superblock before displaying it. If this appears to do
1042the right thing, then the array can be successfully assembled using
1043.BR "\-\-assemble \-\-update=sparc2.2" .
1044
1045.TP
1046.BR \-X ", " \-\-examine\-bitmap
1047Report information about a bitmap file.
1048The argument is either an external bitmap file or an array component
1049in case of an internal bitmap.
1050
1051.TP
1052.BR \-R ", " \-\-run
1053start a partially built array.
1054
1055.TP
1056.BR \-S ", " \-\-stop
1057deactivate array, releasing all resources.
1058
1059.TP
1060.BR \-o ", " \-\-readonly
1061mark array as readonly.
1062
1063.TP
1064.BR \-w ", " \-\-readwrite
1065mark array as readwrite.
1066
1067.TP
1068.B \-\-zero\-superblock
1069If the device contains a valid md superblock, the block is
1070overwritten with zeros. With
1071.B \-\-force
1072the block where the superblock would be is overwritten even if it
1073doesn't appear to be valid.
1074
1075.TP
1076.BR \-t ", " \-\-test
1077When used with
1078.BR \-\-detail ,
1079the exit status of
1080.I mdadm
1081is set to reflect the status of the device.
1082
1083.TP
1084.BR \-W ", " \-\-wait
1085For each md device given, wait for any resync, recovery, or reshape
1086activity to finish before returning.
1087.I mdadm
1088will return with success if it actually waited for every device
1089listed, otherwise it will return failure.
1090
1091.TP
1092.BR \-\-wait\-clean
1093For each md device given, or each device in /proc/mdstat if
1094.B \-\-scan
1095is given, arrange for the array to be marked clean as soon as possible.
1096Also, quiesce resync so that the monitor for external metadata arrays
1097(mdmon) has an opportunity to checkpoint the resync position.
1098.I mdadm
1099will return with success if the array uses external metadata and we
1100successfully waited. For native arrays this returns immediately as the
1101kernel handles both dirty-clean transitions and resync checkpointing in
1102the kernel at shutdown. No action is taken if safe-mode handling is
1103disabled.
1104
1105.SH For Incremental Assembly mode:
1106.TP
1107.BR \-\-rebuild\-map ", " \-r
1108Rebuild the map file
1109.RB ( /var/run/mdadm/map )
1110that
1111.I mdadm
1112uses to help track which arrays are currently being assembled.
1113
1114.TP
1115.BR \-\-run ", " \-R
1116Run any array assembled as soon as a minimal number of devices are
1117available, rather than waiting until all expected devices are present.
1118
1119.TP
1120.B \-\-no\-degraded
1121This allows the hot-plug system to prevent arrays from running when it knows
1122that more disks may arrive later in the discovery process.
1123
1124.TP
1125.BR \-\-scan ", " \-s
1126Only meaningful with
1127.B \-R
1128this will scan the
1129.B map
1130file for arrays that are being incrementally assembled and will try to
1131start any that are not already started. If any such array is listed
1132in
1133.B mdadm.conf
1134as requiring an external bitmap, that bitmap will be attached first.
1135
1136.SH For Monitor mode:
1137.TP
1138.BR \-m ", " \-\-mail
1139Give a mail address to send alerts to.
1140
1141.TP
1142.BR \-p ", " \-\-program ", " \-\-alert
1143Give a program to be run whenever an event is detected.
1144
1145.TP
1146.BR \-y ", " \-\-syslog
1147Cause all events to be reported through 'syslog'. The messages have
1148facility of 'daemon' and varying priorities.
1149
1150.TP
1151.BR \-d ", " \-\-delay
1152Give a delay in seconds.
1153.I mdadm
1154polls the md arrays and then waits this many seconds before polling
1155again. The default is 60 seconds.
1156
1157.TP
1158.BR \-f ", " \-\-daemonise
1159Tell
1160.I mdadm
1161to run as a background daemon if it decides to monitor anything. This
1162causes it to fork and run in the child, and to disconnect form the
1163terminal. The process id of the child is written to stdout.
1164This is useful with
1165.B \-\-scan
1166which will only continue monitoring if a mail address or alert program
1167is found in the config file.
1168
1169.TP
1170.BR \-i ", " \-\-pid\-file
1171When
1172.I mdadm
1173is running in daemon mode, write the pid of the daemon process to
1174the specified file, instead of printing it on standard output.
1175
1176.TP
1177.BR \-1 ", " \-\-oneshot
1178Check arrays only once. This will generate
1179.B NewArray
1180events and more significantly
1181.B DegradedArray
1182and
1183.B SparesMissing
1184events. Running
1185.in +5
1186.B " mdadm \-\-monitor \-\-scan \-1"
1187.in -5
1188from a cron script will ensure regular notification of any degraded arrays.
1189
1190.TP
1191.BR \-t ", " \-\-test
1192Generate a
1193.B TestMessage
1194alert for every array found at startup. This alert gets mailed and
1195passed to the alert program. This can be used for testing that alert
1196message do get through successfully.
1197
1198.SH ASSEMBLE MODE
1199
1200.HP 12
1201Usage:
1202.B mdadm \-\-assemble
1203.I md-device options-and-component-devices...
1204.HP 12
1205Usage:
1206.B mdadm \-\-assemble \-\-scan
1207.I md-devices-and-options...
1208.HP 12
1209Usage:
1210.B mdadm \-\-assemble \-\-scan
1211.I options...
1212
1213.PP
1214This usage assembles one or more raid arrays from pre-existing components.
1215For each array, mdadm needs to know the md device, the identity of the
1216array, and a number of component-devices. These can be found in a number of ways.
1217
1218In the first usage example (without the
1219.BR \-\-scan )
1220the first device given is the md device.
1221In the second usage example, all devices listed are treated as md
1222devices and assembly is attempted.
1223In the third (where no devices are listed) all md devices that are
1224listed in the configuration file are assembled. Then any arrays that
1225can be found on unused devices will also be assembled.
1226
1227If precisely one device is listed, but
1228.B \-\-scan
1229is not given, then
1230.I mdadm
1231acts as though
1232.B \-\-scan
1233was given and identity information is extracted from the configuration file.
1234
1235The identity can be given with the
1236.B \-\-uuid
1237option, with the
1238.B \-\-super\-minor
1239option, will be taken from the md-device record in the config file, or
1240will be taken from the super block of the first component-device
1241listed on the command line.
1242
1243Devices can be given on the
1244.B \-\-assemble
1245command line or in the config file. Only devices which have an md
1246superblock which contains the right identity will be considered for
1247any array.
1248
1249The config file is only used if explicitly named with
1250.B \-\-config
1251or requested with (a possibly implicit)
1252.BR \-\-scan .
1253In the later case,
1254.B /etc/mdadm.conf
1255or
1256.B /etc/mdadm/mdadm.conf
1257is used.
1258
1259If
1260.B \-\-scan
1261is not given, then the config file will only be used to find the
1262identity of md arrays.
1263
1264Normally the array will be started after it is assembled. However if
1265.B \-\-scan
1266is not given and insufficient drives were listed to start a complete
1267(non-degraded) array, then the array is not started (to guard against
1268usage errors). To insist that the array be started in this case (as
1269may work for RAID1, 4, 5, 6, or 10), give the
1270.B \-\-run
1271flag.
1272
1273If the md device does not exist, then it will be created providing the
1274intent is clear. i.e. the name must be in a standard form, or the
1275.B \-\-auto
1276option must be given to clarify how and whether the device should be
1277created.
1278This can be useful for handling partitioned devices (which don't have
1279a stable device number \(em it can change after a reboot) and when using
1280"udev" to manage your
1281.B /dev
1282tree (udev cannot handle md devices because of the unusual device
1283initialisation conventions).
1284
1285If the option to "auto" is "mdp" or "part" or (on the command line
1286only) "p", then mdadm will create a partitionable array, using the
1287first free one that is not in use and does not already have an entry
1288in /dev (apart from numeric /dev/md* entries).
1289
1290If the option to "auto" is "yes" or "md" or (on the command line)
1291nothing, then mdadm will create a traditional, non-partitionable md
1292array.
1293
1294It is expected that the "auto" functionality will be used to create
1295device entries with meaningful names such as "/dev/md/home" or
1296"/dev/md/root", rather than names based on the numerical array number.
1297
1298When using option "auto" to create a partitionable array, the device
1299files for the first 4 partitions are also created. If a different
1300number is required it can be simply appended to the auto option.
1301e.g. "auto=part8". Partition names are created by appending a digit
1302string to the device name, with an intervening "p" if the device name
1303ends with a digit.
1304
1305The
1306.B \-\-auto
1307option is also available in Build and Create modes. As those modes do
1308not use a config file, the "auto=" config option does not apply to
1309these modes.
1310
1311.SS Auto Assembly
1312When
1313.B \-\-assemble
1314is used with
1315.B \-\-scan
1316and no devices are listed,
1317.I mdadm
1318will first attempt to assemble all the arrays listed in the config
1319file.
1320
1321It will then look further for possible arrays and will try to assemble
1322anything that it finds. Arrays which are tagged as belonging to the given
1323homehost will be assembled and started normally. Arrays which do not
1324obviously belong to this host are given names that are expected not to
1325conflict with anything local, and are started "read-auto" so that
1326nothing is written to any device until the array is written to. i.e.
1327automatic resync etc is delayed.
1328
1329If
1330.I mdadm
1331finds a consistent set of devices that look like they should comprise
1332an array, and if the superblock is tagged as belonging to the given
1333home host, it will automatically choose a device name and try to
1334assemble the array. If the array uses version-0.90 metadata, then the
1335.B minor
1336number as recorded in the superblock is used to create a name in
1337.B /dev/md/
1338so for example
1339.BR /dev/md/3 .
1340If the array uses version-1 metadata, then the
1341.B name
1342from the superblock is used to similarly create a name in
1343.BR /dev/md
1344(the name will have any 'host' prefix stripped first).
1345
1346If
1347.I mdadm
1348cannot find any array for the given host at all, and if
1349.B \-\-auto\-update\-homehost
1350is given, then
1351.I mdadm
1352will search again for any array (not just an array created for this
1353host) and will assemble each assuming
1354.BR \-\-update=homehost .
1355This will change the host tag in the superblock so that on the next run,
1356these arrays will be found without the second pass. The intention of
1357this feature is to support transitioning a set of md arrays to using
1358homehost tagging.
1359
1360The reason for requiring arrays to be tagged with the homehost for
1361auto assembly is to guard against problems that can arise when moving
1362devices from one host to another.
1363
1364.SH BUILD MODE
1365
1366.HP 12
1367Usage:
1368.B mdadm \-\-build
1369.I md-device
1370.BI \-\-chunk= X
1371.BI \-\-level= Y
1372.BI \-\-raid\-devices= Z
1373.I devices
1374
1375.PP
1376This usage is similar to
1377.BR \-\-create .
1378The difference is that it creates an array without a superblock. With
1379these arrays there is no difference between initially creating the array and
1380subsequently assembling the array, except that hopefully there is useful
1381data there in the second case.
1382
1383The level may raid0, linear, multipath, or faulty, or one of their
1384synonyms. All devices must be listed and the array will be started
1385once complete.
1386
1387.SH CREATE MODE
1388
1389.HP 12
1390Usage:
1391.B mdadm \-\-create
1392.I md-device
1393.BI \-\-chunk= X
1394.BI \-\-level= Y
1395.br
1396.BI \-\-raid\-devices= Z
1397.I devices
1398
1399.PP
1400This usage will initialise a new md array, associate some devices with
1401it, and activate the array.
1402
1403If the
1404.B \-\-auto
1405option is given (as described in more detail in the section on
1406Assemble mode), then the md device will be created with a suitable
1407device number if necessary.
1408
1409As devices are added, they are checked to see if they contain raid
1410superblocks or filesystems. They are also checked to see if the variance in
1411device size exceeds 1%.
1412
1413If any discrepancy is found, the array will not automatically be run, though
1414the presence of a
1415.B \-\-run
1416can override this caution.
1417
1418To create a "degraded" array in which some devices are missing, simply
1419give the word "\fBmissing\fP"
1420in place of a device name. This will cause
1421.I mdadm
1422to leave the corresponding slot in the array empty.
1423For a RAID4 or RAID5 array at most one slot can be
1424"\fBmissing\fP"; for a RAID6 array at most two slots.
1425For a RAID1 array, only one real device needs to be given. All of the
1426others can be
1427"\fBmissing\fP".
1428
1429When creating a RAID5 array,
1430.I mdadm
1431will automatically create a degraded array with an extra spare drive.
1432This is because building the spare into a degraded array is in general faster than resyncing
1433the parity on a non-degraded, but not clean, array. This feature can
1434be overridden with the
1435.B \-\-force
1436option.
1437
1438When creating an array with version-1 metadata a name for the array is
1439required.
1440If this is not given with the
1441.B \-\-name
1442option,
1443.I mdadm
1444will choose a name based on the last component of the name of the
1445device being created. So if
1446.B /dev/md3
1447is being created, then the name
1448.B 3
1449will be chosen.
1450If
1451.B /dev/md/home
1452is being created, then the name
1453.B home
1454will be used.
1455
1456When creating a partition based array, using
1457.I mdadm
1458with version-1.x metadata, the partition type should be set to
1459.B 0xDA
1460(non fs-data). This type selection allows for greater precision since
1461using any other [RAID auto-detect (0xFD) or a GNU/Linux partition (0x83)],
1462might create problems in the event of array recovery through a live cdrom.
1463
1464A new array will normally get a randomly assigned 128bit UUID which is
1465very likely to be unique. If you have a specific need, you can choose
1466a UUID for the array by giving the
1467.B \-\-uuid=
1468option. Be warned that creating two arrays with the same UUID is a
1469recipe for disaster. Also, using
1470.B \-\-uuid=
1471when creating a v0.90 array will silently override any
1472.B \-\-homehost=
1473setting.
1474.\"If the
1475.\".B \-\-size
1476.\"option is given, it is not necessary to list any component-devices in this command.
1477.\"They can be added later, before a
1478.\".B \-\-run.
1479.\"If no
1480.\".B \-\-size
1481.\"is given, the apparent size of the smallest drive given is used.
1482
1483When creating an array within a
1484.B CONTAINER
1485.I mdadm
1486can be given either the list of devices to use, or simply the name of
1487the container. The former case gives control over which devices in
1488the container will be used for the array. The latter case allows
1489.I mdadm
1490to automatically choose which devices to use based on how much spare
1491space is available.
1492
1493The General Management options that are valid with
1494.B \-\-create
1495are:
1496.TP
1497.B \-\-run
1498insist on running the array even if some devices look like they might
1499be in use.
1500
1501.TP
1502.B \-\-readonly
1503start the array readonly \(em not supported yet.
1504
1505
1506.SH MANAGE MODE
1507.HP 12
1508Usage:
1509.B mdadm
1510.I device
1511.I options... devices...
1512.PP
1513
1514This usage will allow individual devices in an array to be failed,
1515removed or added. It is possible to perform multiple operations with
1516on command. For example:
1517.br
1518.B " mdadm /dev/md0 \-f /dev/hda1 \-r /dev/hda1 \-a /dev/hda1"
1519.br
1520will firstly mark
1521.B /dev/hda1
1522as faulty in
1523.B /dev/md0
1524and will then remove it from the array and finally add it back
1525in as a spare. However only one md array can be affected by a single
1526command.
1527
1528.SH MISC MODE
1529.HP 12
1530Usage:
1531.B mdadm
1532.I options ...
1533.I devices ...
1534.PP
1535
1536MISC mode includes a number of distinct operations that
1537operate on distinct devices. The operations are:
1538.TP
1539.B \-\-query
1540The device is examined to see if it is
1541(1) an active md array, or
1542(2) a component of an md array.
1543The information discovered is reported.
1544
1545.TP
1546.B \-\-detail
1547The device should be an active md device.
1548.B mdadm
1549will display a detailed description of the array.
1550.B \-\-brief
1551or
1552.B \-\-scan
1553will cause the output to be less detailed and the format to be
1554suitable for inclusion in
1555.BR /etc/mdadm.conf .
1556The exit status of
1557.I mdadm
1558will normally be 0 unless
1559.I mdadm
1560failed to get useful information about the device(s); however, if the
1561.B \-\-test
1562option is given, then the exit status will be:
1563.RS
1564.TP
15650
1566The array is functioning normally.
1567.TP
15681
1569The array has at least one failed device.
1570.TP
15712
1572The array has multiple failed devices such that it is unusable.
1573.TP
15744
1575There was an error while trying to get information about the device.
1576.RE
1577
1578.TP
1579.B \-\-detail\-platform
1580Print detail of the platform's raid capabilities (firmware / hardware
1581topology). If the metadata is specified with
1582.B \-e
1583or
1584.B \-\-metadata=
1585then the return status will be:
1586.RS
1587.TP
15880
1589metadata successfully enumerated its platform components on this system
1590.TP
15911
1592metadata is platform independent
1593.TP
15942
1595metadata failed to find its platform components on this system
1596.RE
1597
1598.TP
1599.B \-\-examine
1600The device should be a component of an md array.
1601.I mdadm
1602will read the md superblock of the device and display the contents.
1603If
1604.B \-\-brief
1605or
1606.B \-\-scan
1607is given, then multiple devices that are components of the one array
1608are grouped together and reported in a single entry suitable
1609for inclusion in
1610.BR /etc/mdadm.conf .
1611
1612Having
1613.B \-\-scan
1614without listing any devices will cause all devices listed in the
1615config file to be examined.
1616
1617.TP
1618.B \-\-stop
1619The devices should be active md arrays which will be deactivated, as
1620long as they are not currently in use.
1621
1622.TP
1623.B \-\-run
1624This will fully activate a partially assembled md array.
1625
1626.TP
1627.B \-\-readonly
1628This will mark an active array as read-only, providing that it is
1629not currently being used.
1630
1631.TP
1632.B \-\-readwrite
1633This will change a
1634.B readonly
1635array back to being read/write.
1636
1637.TP
1638.B \-\-scan
1639For all operations except
1640.BR \-\-examine ,
1641.B \-\-scan
1642will cause the operation to be applied to all arrays listed in
1643.BR /proc/mdstat .
1644For
1645.BR \-\-examine,
1646.B \-\-scan
1647causes all devices listed in the config file to be examined.
1648
1649
1650.SH MONITOR MODE
1651
1652.HP 12
1653Usage:
1654.B mdadm \-\-monitor
1655.I options... devices...
1656
1657.PP
1658This usage causes
1659.I mdadm
1660to periodically poll a number of md arrays and to report on any events
1661noticed.
1662.I mdadm
1663will never exit once it decides that there are arrays to be checked,
1664so it should normally be run in the background.
1665
1666As well as reporting events,
1667.I mdadm
1668may move a spare drive from one array to another if they are in the
1669same
1670.B spare-group
1671and if the destination array has a failed drive but no spares.
1672
1673If any devices are listed on the command line,
1674.I mdadm
1675will only monitor those devices. Otherwise all arrays listed in the
1676configuration file will be monitored. Further, if
1677.B \-\-scan
1678is given, then any other md devices that appear in
1679.B /proc/mdstat
1680will also be monitored.
1681
1682The result of monitoring the arrays is the generation of events.
1683These events are passed to a separate program (if specified) and may
1684be mailed to a given E-mail address.
1685
1686When passing events to a program, the program is run once for each event,
1687and is given 2 or 3 command-line arguments: the first is the
1688name of the event (see below), the second is the name of the
1689md device which is affected, and the third is the name of a related
1690device if relevant (such as a component device that has failed).
1691
1692If
1693.B \-\-scan
1694is given, then a program or an E-mail address must be specified on the
1695command line or in the config file. If neither are available, then
1696.I mdadm
1697will not monitor anything.
1698Without
1699.B \-\-scan,
1700.I mdadm
1701will continue monitoring as long as something was found to monitor. If
1702no program or email is given, then each event is reported to
1703.BR stdout .
1704
1705The different events are:
1706
1707.RS 4
1708.TP
1709.B DeviceDisappeared
1710An md array which previously was configured appears to no longer be
1711configured. (syslog priority: Critical)
1712
1713If
1714.I mdadm
1715was told to monitor an array which is RAID0 or Linear, then it will
1716report
1717.B DeviceDisappeared
1718with the extra information
1719.BR Wrong-Level .
1720This is because RAID0 and Linear do not support the device-failed,
1721hot-spare and resync operations which are monitored.
1722
1723.TP
1724.B RebuildStarted
1725An md array started reconstruction. (syslog priority: Warning)
1726
1727.TP
1728.BI Rebuild NN
1729Where
1730.I NN
1731is 20, 40, 60, or 80, this indicates that rebuild has passed that many
1732percentage of the total. (syslog priority: Warning)
1733
1734.TP
1735.B RebuildFinished
1736An md array that was rebuilding, isn't any more, either because it
1737finished normally or was aborted. (syslog priority: Warning)
1738
1739.TP
1740.B Fail
1741An active component device of an array has been marked as
1742faulty. (syslog priority: Critical)
1743
1744.TP
1745.B FailSpare
1746A spare component device which was being rebuilt to replace a faulty
1747device has failed. (syslog priority: Critical)
1748
1749.TP
1750.B SpareActive
1751A spare component device which was being rebuilt to replace a faulty
1752device has been successfully rebuilt and has been made active.
1753(syslog priority: Info)
1754
1755.TP
1756.B NewArray
1757A new md array has been detected in the
1758.B /proc/mdstat
1759file. (syslog priority: Info)
1760
1761.TP
1762.B DegradedArray
1763A newly noticed array appears to be degraded. This message is not
1764generated when
1765.I mdadm
1766notices a drive failure which causes degradation, but only when
1767.I mdadm
1768notices that an array is degraded when it first sees the array.
1769(syslog priority: Critical)
1770
1771.TP
1772.B MoveSpare
1773A spare drive has been moved from one array in a
1774.B spare-group
1775to another to allow a failed drive to be replaced.
1776(syslog priority: Info)
1777
1778.TP
1779.B SparesMissing
1780If
1781.I mdadm
1782has been told, via the config file, that an array should have a certain
1783number of spare devices, and
1784.I mdadm
1785detects that it has fewer than this number when it first sees the
1786array, it will report a
1787.B SparesMissing
1788message.
1789(syslog priority: Warning)
1790
1791.TP
1792.B TestMessage
1793An array was found at startup, and the
1794.B \-\-test
1795flag was given.
1796(syslog priority: Info)
1797.RE
1798
1799Only
1800.B Fail,
1801.B FailSpare,
1802.B DegradedArray,
1803.B SparesMissing
1804and
1805.B TestMessage
1806cause Email to be sent. All events cause the program to be run.
1807The program is run with two or three arguments: the event
1808name, the array device and possibly a second device.
1809
1810Each event has an associated array device (e.g.
1811.BR /dev/md1 )
1812and possibly a second device. For
1813.BR Fail ,
1814.BR FailSpare ,
1815and
1816.B SpareActive
1817the second device is the relevant component device.
1818For
1819.B MoveSpare
1820the second device is the array that the spare was moved from.
1821
1822For
1823.I mdadm
1824to move spares from one array to another, the different arrays need to
1825be labeled with the same
1826.B spare-group
1827in the configuration file. The
1828.B spare-group
1829name can be any string; it is only necessary that different spare
1830groups use different names.
1831
1832When
1833.I mdadm
1834detects that an array in a spare group has fewer active
1835devices than necessary for the complete array, and has no spare
1836devices, it will look for another array in the same spare group that
1837has a full complement of working drive and a spare. It will then
1838attempt to remove the spare from the second drive and add it to the
1839first.
1840If the removal succeeds but the adding fails, then it is added back to
1841the original array.
1842
1843.SH GROW MODE
1844The GROW mode is used for changing the size or shape of an active
1845array.
1846For this to work, the kernel must support the necessary change.
1847Various types of growth are being added during 2.6 development,
1848including restructuring a raid5 array to have more active devices.
1849
1850Currently the only support available is to
1851.IP \(bu 4
1852change the "size" attribute
1853for RAID1, RAID5 and RAID6.
1854.IP \(bu 4
1855increase the "raid\-devices" attribute of RAID1, RAID5, and RAID6.
1856.IP \(bu 4
1857add a write-intent bitmap to any array which supports these bitmaps, or
1858remove a write-intent bitmap from such an array.
1859.PP
1860
1861GROW mode is not currently supported for
1862.B CONTAINERS
1863or arrays inside containers.
1864
1865.SS SIZE CHANGES
1866Normally when an array is built the "size" it taken from the smallest
1867of the drives. If all the small drives in an arrays are, one at a
1868time, removed and replaced with larger drives, then you could have an
1869array of large drives with only a small amount used. In this
1870situation, changing the "size" with "GROW" mode will allow the extra
1871space to start being used. If the size is increased in this way, a
1872"resync" process will start to make sure the new parts of the array
1873are synchronised.
1874
1875Note that when an array changes size, any filesystem that may be
1876stored in the array will not automatically grow to use the space. The
1877filesystem will need to be explicitly told to use the extra space.
1878
1879.SS RAID-DEVICES CHANGES
1880
1881A RAID1 array can work with any number of devices from 1 upwards
1882(though 1 is not very useful). There may be times which you want to
1883increase or decrease the number of active devices. Note that this is
1884different to hot-add or hot-remove which changes the number of
1885inactive devices.
1886
1887When reducing the number of devices in a RAID1 array, the slots which
1888are to be removed from the array must already be vacant. That is, the
1889devices which were in those slots must be failed and removed.
1890
1891When the number of devices is increased, any hot spares that are
1892present will be activated immediately.
1893
1894Increasing the number of active devices in a RAID5 is much more
1895effort. Every block in the array will need to be read and written
1896back to a new location. From 2.6.17, the Linux Kernel is able to do
1897this safely, including restart and interrupted "reshape".
1898
1899When relocating the first few stripes on a raid5, it is not possible
1900to keep the data on disk completely consistent and crash-proof. To
1901provide the required safety, mdadm disables writes to the array while
1902this "critical section" is reshaped, and takes a backup of the data
1903that is in that section. This backup is normally stored in any spare
1904devices that the array has, however it can also be stored in a
1905separate file specified with the
1906.B \-\-backup\-file
1907option. If this option is used, and the system does crash during the
1908critical period, the same file must be passed to
1909.B \-\-assemble
1910to restore the backup and reassemble the array.
1911
1912.SS BITMAP CHANGES
1913
1914A write-intent bitmap can be added to, or removed from, an active
1915array. Either internal bitmaps, or bitmaps stored in a separate file,
1916can be added. Note that if you add a bitmap stored in a file which is
1917in a filesystem that is on the raid array being affected, the system
1918will deadlock. The bitmap must be on a separate filesystem.
1919
1920.SH INCREMENTAL MODE
1921
1922.HP 12
1923Usage:
1924.B mdadm \-\-incremental
1925.RB [ \-\-run ]
1926.RB [ \-\-quiet ]
1927.I component-device
1928.HP 12
1929Usage:
1930.B mdadm \-\-incremental \-\-rebuild
1931.HP 12
1932Usage:
1933.B mdadm \-\-incremental \-\-run \-\-scan
1934
1935
1936.PP
1937This mode is designed to be used in conjunction with a device
1938discovery system. As devices are found in a system, they can be
1939passed to
1940.B "mdadm \-\-incremental"
1941to be conditionally added to an appropriate array.
1942
1943If the device passed is a
1944.B CONTAINER
1945device created by a previous call to
1946.IR mdadm ,
1947then rather than trying to add that device to an array, all the arrays
1948described by the metadata of the container will be started.
1949
1950.I mdadm
1951performs a number of tests to determine if the device is part of an
1952array, and which array it should be part of. If an appropriate array
1953is found, or can be created,
1954.I mdadm
1955adds the device to the array and conditionally starts the array.
1956
1957Note that
1958.I mdadm
1959will only add devices to an array which were previously working
1960(active or spare) parts of that array. It does not currently support
1961automatic inclusion of a new drive as a spare in some array.
1962
1963The tests that
1964.I mdadm
1965makes are as follow:
1966.IP +
1967Is the device permitted by
1968.BR mdadm.conf ?
1969That is, is it listed in a
1970.B DEVICES
1971line in that file. If
1972.B DEVICES
1973is absent then the default it to allow any device. Similar if
1974.B DEVICES
1975contains the special word
1976.B partitions
1977then any device is allowed. Otherwise the device name given to
1978.I mdadm
1979must match one of the names or patterns in a
1980.B DEVICES
1981line.
1982
1983.IP +
1984Does the device have a valid md superblock. If a specific metadata
1985version is request with
1986.B \-\-metadata
1987or
1988.B \-e
1989then only that style of metadata is accepted, otherwise
1990.I mdadm
1991finds any known version of metadata. If no
1992.I md
1993metadata is found, the device is rejected.
1994
1995.IP +
1996Does the metadata match an expected array?
1997The metadata can match in two ways. Either there is an array listed
1998in
1999.B mdadm.conf
2000which identifies the array (either by UUID, by name, by device list,
2001or by minor-number), or the array was created with a
2002.B homehost
2003specified and that
2004.B homehost
2005matches the one in
2006.B mdadm.conf
2007or on the command line.
2008If
2009.I mdadm
2010is not able to positively identify the array as belonging to the
2011current host, the device will be rejected.
2012
2013.IP +
2014.I mdadm
2015keeps a list of arrays that it has partially assembled in
2016.B /var/run/mdadm/map
2017(or
2018.B /var/run/mdadm.map
2019if the directory doesn't exist). If no array exists which matches
2020the metadata on the new device,
2021.I mdadm
2022must choose a device name and unit number. It does this based on any
2023name given in
2024.B mdadm.conf
2025or any name information stored in the metadata. If this name
2026suggests a unit number, that number will be used, otherwise a free
2027unit number will be chosen. Normally
2028.I mdadm
2029will prefer to create a partitionable array, however if the
2030.B CREATE
2031line in
2032.B mdadm.conf
2033suggests that a non-partitionable array is preferred, that will be
2034honoured.
2035
2036.IP +
2037Once an appropriate array is found or created and the device is added,
2038.I mdadm
2039must decide if the array is ready to be started. It will
2040normally compare the number of available (non-spare) devices to the
2041number of devices that the metadata suggests need to be active. If
2042there are at least that many, the array will be started. This means
2043that if any devices are missing the array will not be restarted.
2044
2045As an alternative,
2046.B \-\-run
2047may be passed to
2048.I mdadm
2049in which case the array will be run as soon as there are enough
2050devices present for the data to be accessible. For a raid1, that
2051means one device will start the array. For a clean raid5, the array
2052will be started as soon as all but one drive is present.
2053
2054Note that neither of these approaches is really ideal. If it can
2055be known that all device discovery has completed, then
2056.br
2057.B " mdadm \-IRs"
2058.br
2059can be run which will try to start all arrays that are being
2060incrementally assembled. They are started in "read-auto" mode in
2061which they are read-only until the first write request. This means
2062that no metadata updates are made and no attempt at resync or recovery
2063happens. Further devices that are found before the first write can
2064still be added safely.
2065
2066
2067.SH ENVIRONMENT
2068This section describes environment variables that affect how mdadm
2069operates.
2070
2071.TP
2072.B MDADM_NO_MDMON
2073Setting this value to 1 will prevent mdadm from automatically launching
2074mdmon. This variable is intended primarily for debugging mdadm/mdmon.
2075
2076.TP
2077.B MDADM_NO_UDEV
2078Normally,
2079.I mdadm
2080does not create any device nodes in /dev, but leaves that task to
2081.IR udev .
2082If
2083.I udev
2084appears not to be configured, or if this environment variable is set
2085to '1', the
2086.I mdadm
2087will create and devices that are needed.
2088
2089.SH EXAMPLES
2090
2091.B " mdadm \-\-query /dev/name-of-device"
2092.br
2093This will find out if a given device is a raid array, or is part of
2094one, and will provide brief information about the device.
2095
2096.B " mdadm \-\-assemble \-\-scan"
2097.br
2098This will assemble and start all arrays listed in the standard config
2099file. This command will typically go in a system startup file.
2100
2101.B " mdadm \-\-stop \-\-scan"
2102.br
2103This will shut down all arrays that can be shut down (i.e. are not
2104currently in use). This will typically go in a system shutdown script.
2105
2106.B " mdadm \-\-follow \-\-scan \-\-delay=120"
2107.br
2108If (and only if) there is an Email address or program given in the
2109standard config file, then
2110monitor the status of all arrays listed in that file by
2111polling them ever 2 minutes.
2112
2113.B " mdadm \-\-create /dev/md0 \-\-level=1 \-\-raid\-devices=2 /dev/hd[ac]1"
2114.br
2115Create /dev/md0 as a RAID1 array consisting of /dev/hda1 and /dev/hdc1.
2116
2117.br
2118.B " echo 'DEVICE /dev/hd*[0\-9] /dev/sd*[0\-9]' > mdadm.conf"
2119.br
2120.B " mdadm \-\-detail \-\-scan >> mdadm.conf"
2121.br
2122This will create a prototype config file that describes currently
2123active arrays that are known to be made from partitions of IDE or SCSI drives.
2124This file should be reviewed before being used as it may
2125contain unwanted detail.
2126
2127.B " echo 'DEVICE /dev/hd[a\-z] /dev/sd*[a\-z]' > mdadm.conf"
2128.br
2129.B " mdadm \-\-examine \-\-scan \-\-config=mdadm.conf >> mdadm.conf"
2130.br
2131This will find arrays which could be assembled from existing IDE and
2132SCSI whole drives (not partitions), and store the information in the
2133format of a config file.
2134This file is very likely to contain unwanted detail, particularly
2135the
2136.B devices=
2137entries. It should be reviewed and edited before being used as an
2138actual config file.
2139
2140.B " mdadm \-\-examine \-\-brief \-\-scan \-\-config=partitions"
2141.br
2142.B " mdadm \-Ebsc partitions"
2143.br
2144Create a list of devices by reading
2145.BR /proc/partitions ,
2146scan these for RAID superblocks, and printout a brief listing of all
2147that were found.
2148
2149.B " mdadm \-Ac partitions \-m 0 /dev/md0"
2150.br
2151Scan all partitions and devices listed in
2152.BR /proc/partitions
2153and assemble
2154.B /dev/md0
2155out of all such devices with a RAID superblock with a minor number of 0.
2156
2157.B " mdadm \-\-monitor \-\-scan \-\-daemonise > /var/run/mdadm"
2158.br
2159If config file contains a mail address or alert program, run mdadm in
2160the background in monitor mode monitoring all md devices. Also write
2161pid of mdadm daemon to
2162.BR /var/run/mdadm .
2163
2164.B " mdadm \-Iq /dev/somedevice"
2165.br
2166Try to incorporate newly discovered device into some array as
2167appropriate.
2168
2169.B " mdadm \-\-incremental \-\-rebuild \-\-run \-\-scan"
2170.br
2171Rebuild the array map from any current arrays, and then start any that
2172can be started.
2173
2174.B " mdadm /dev/md4 --fail detached --remove detached"
2175.br
2176Any devices which are components of /dev/md4 will be marked as faulty
2177and then remove from the array.
2178
2179.B " mdadm --create /dev/md/ddf --metadata=ddf --raid-disks 6 /dev/sd[a-f]"
2180.br
2181Create a DDF array over 6 devices.
2182
2183.B " mdadm --create /dev/md/home -n3 -l5 -z 30000000 /dev/md/ddf"
2184.br
2185Create a raid5 array over any 3 devices in the given DDF set. Use
2186only 30 gigabytes of each device.
2187
2188.B " mdadm -A /dev/md/ddf1 /dev/sd[a-f]"
2189.br
2190Assemble a pre-exist ddf array.
2191
2192.B " mdadm -I /dev/md/ddf1"
2193.br
2194Assemble all arrays contained in the ddf array, assigning names as
2195appropriate.
2196
2197.B " mdadm \-\-create \-\-help"
2198.br
2199Provide help about the Create mode.
2200
2201.B " mdadm \-\-config \-\-help"
2202.br
2203Provide help about the format of the config file.
2204
2205.B " mdadm \-\-help"
2206.br
2207Provide general help.
2208
2209
2210.SH FILES
2211
2212.SS /proc/mdstat
2213
2214If you're using the
2215.B /proc
2216filesystem,
2217.B /proc/mdstat
2218lists all active md devices with information about them.
2219.I mdadm
2220uses this to find arrays when
2221.B \-\-scan
2222is given in Misc mode, and to monitor array reconstruction
2223on Monitor mode.
2224
2225
2226.SS /etc/mdadm.conf
2227
2228The config file lists which devices may be scanned to see if
2229they contain MD super block, and gives identifying information
2230(e.g. UUID) about known MD arrays. See
2231.BR mdadm.conf (5)
2232for more details.
2233
2234.SS /var/run/mdadm/map
2235When
2236.B \-\-incremental
2237mode is used, this file gets a list of arrays currently being created.
2238If
2239.B /var/run/mdadm
2240does not exist as a directory, then
2241.B /var/run/mdadm.map
2242is used instead.
2243
2244.SH DEVICE NAMES
2245
2246.I mdadm
2247understand two sorts of names for array devices.
2248
2249The first is the so-called 'standard' format name, which matches the
2250names used by the kernel and which appear in
2251.IR /proc/mdstat .
2252
2253The second sort can be freely chosen, but must reside in
2254.IR /dev/md/ .
2255When giving a device name to
2256.I mdadm
2257to create or assemble an array, either full path name such as
2258.I /dev/md0
2259or
2260.I /dev/md/home
2261can be given, or just the suffix of the second sort of name, such as
2262.I home
2263can be given.
2264
2265When
2266.I mdadm
2267chooses device names during auto-assembly, it will normally add a
2268small sequence number to the end of the name to avoid conflicted
2269between multiple arrays that have the same name. If
2270.I mdadm
2271can reasonably determine that the array really is meant for this host,
2272either by a hostname in the metadata, or by the presence of the array
2273in /etc/mdadm.conf, then it will leave of the suffix if possible.
2274
2275The standard names for non-partitioned arrays (the only sort of md
2276array available in 2.4 and earlier) are of the form
2277.IP
2278/dev/mdNN
2279.PP
2280where NN is a number.
2281The standard names for partitionable arrays (as available from 2.6
2282onwards) are of the form
2283.IP
2284/dev/md_dNN
2285.PP
2286Partition numbers should be indicated by added "pMM" to these, thus "/dev/md/d1p2".
2287.PP
2288From kernel version, 2.6.28 the "non-partitioned array" can actually
2289be partitioned. So the "md_dNN" names are no longer needed, and
2290partitions such as "/dev/mdNNpXX" are possible.
2291
2292.SH NOTE
2293.I mdadm
2294was previously known as
2295.IR mdctl .
2296.P
2297.I mdadm
2298is completely separate from the
2299.I raidtools
2300package, and does not use the
2301.I /etc/raidtab
2302configuration file at all.
2303
2304.SH SEE ALSO
2305For further information on mdadm usage, MD and the various levels of
2306RAID, see:
2307.IP
2308.B http://linux\-raid.osdl.org/
2309.PP
2310(based upon Jakob \(/Ostergaard's Software\-RAID.HOWTO)
2311.\".PP
2312.\"for new releases of the RAID driver check out:
2313.\"
2314.\".IP
2315.\".UR ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2316.\"ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2317.\".UE
2318.\".PP
2319.\"or
2320.\".IP
2321.\".UR http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2322.\"http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2323.\".UE
2324.PP
2325The latest version of
2326.I mdadm
2327should always be available from
2328.IP
2329.B http://www.kernel.org/pub/linux/utils/raid/mdadm/
2330.PP
2331Related man pages:
2332.PP
2333.IR mdadm.conf (5),
2334.IR md (4).
2335.PP
2336.IR raidtab (5),
2337.IR raid0run (8),
2338.IR raidstop (8),
2339.IR mkraid (8).