]> git.ipfire.org Git - thirdparty/mdadm.git/blobdiff - mdadm.8.in
imsm: Allow to specify controller for --detail-platform.
[thirdparty/mdadm.git] / mdadm.8.in
index 6b5017f1d3ff5049d239523c4da31b246e82065b..845c00cdb4732d3be497b4265058818ef5c22fe8 100644 (file)
@@ -5,7 +5,7 @@
 .\"   the Free Software Foundation; either version 2 of the License, or
 .\"   (at your option) any later version.
 .\" See file COPYING in distribution for details.
-.TH MDADM 8 "" v3.1.4
+.TH MDADM 8 "" v3.2.5
 .SH NAME
 mdadm \- manage MD devices
 .I aka
@@ -122,9 +122,10 @@ missing, spare, or failed drives, so there is nothing to monitor.
 .B "Grow"
 Grow (or shrink) an array, or otherwise reshape it in some way.
 Currently supported growth options including changing the active size
-of component devices and changing the number of active devices in RAID
-levels 1/4/5/6, changing the RAID level between 1, 5, and 6, changing
-the chunk size and layout for RAID5 and RAID5, as well as adding or
+of component devices and changing the number of active devices in
+Linear and RAID levels 0/1/4/5/6,
+changing the RAID level between 0, 1, 5, and 6, and between 0 and 10,
+changing the chunk size and layout for RAID 0,4,5,6, as well as adding or
 removing a write-intent bitmap.
 
 .TP
@@ -253,6 +254,18 @@ Avoid printing purely informative messages.  With this,
 .I mdadm
 will be silent unless there is something really important to report.
 
+.TP
+.BR \-\-offroot
+Set first character of argv[0] to @ to indicate mdadm was launched
+from initrd/initramfs and should not be shutdown by systemd as part of
+the regular shutdown process. This option is normally only used by
+the system's initscripts. Please see here for more details on how
+systemd handled argv[0]:
+.IP
+.B http://www.freedesktop.org/wiki/Software/systemd/RootStorageDaemons
+.PP
+
+
 .TP
 .BR \-f ", " \-\-force
 Be more forceful about certain operations.  See the various modes for
@@ -335,7 +348,8 @@ It can easily be moved between hosts with different endian-ness, and a
 recovery operation can be checkpointed and restarted.  The different
 sub-versions store the superblock at different locations on the
 device, either at the end (for 1.0), at the start (for 1.1) or 4K from
-the start (for 1.2).  "1" is equivalent to "1.0".
+the start (for 1.2).  "1" is equivalent to "1.2" (the commonly
+preferred 1.x format).
 'if '{DEFAULT_METADATA}'1.2'  "default" is equivalent to "1.2".
 .IP ddf
 Use the "Industry Standard" DDF (Disk Data Format) format defined by
@@ -375,6 +389,28 @@ will be allowed to use 'local' names (i.e. not ending in '_' followed
 by a digit string).  See below under
 .BR "Auto Assembly" .
 
+.TP
+.B \-\-prefer=
+When
+.I mdadm
+needs to print the name for a device it normally finds the name in
+.B /dev
+which refers to the device and is shortest.  When a path component is
+given with
+.B \-\-prefer
+.I mdadm
+will prefer a longer name if it contains that component.  For example
+.B \-\-prefer=by-uuid
+will prefer a name in a subdirectory of
+.B /dev
+called
+.BR by-uuid .
+
+This functionality is currently only provided by
+.B \-\-detail
+and
+.BR \-\-monitor .
+
 .SH For create, build, or grow:
 
 .TP
@@ -417,22 +453,46 @@ issued.
 A suffix of 'M' or 'G' can be given to indicate Megabytes or
 Gigabytes respectively.
 
+Sometimes a replacement drive can be a little smaller than the
+original drives though this should be minimised by IDEMA standards.
+Such a replacement drive will be rejected by
+.IR md .
+To guard against this it can be useful to set the initial size
+slightly smaller than the smaller device with the aim that it will
+still be larger than any replacement.
+
 This value can be set with
 .B \-\-grow
-for RAID level 1/4/5/6.  If the array was created with a size smaller
-than the currently active drives, the extra space can be accessed
-using
+for RAID level 1/4/5/6 though
+.B CONTAINER
+based arrays such as those with IMSM metadata may not be able to
+support this.
+If the array was created with a size smaller than the currently
+active drives, the extra space can be accessed using
 .BR \-\-grow .
 The size can be given as
 .B max
 which means to choose the largest size that fits on all current drives.
 
-This value can not be used with
+Before reducing the size of the array (with
+.BR "\-\-grow \-\-size=" )
+you should make sure that space isn't needed.  If the device holds a
+filesystem, you would need to resize the filesystem to use less space.
+
+After reducing the array size you should check that the data stored in
+the device is still available.  If the device holds a filesystem, then
+an 'fsck' of the filesystem is a minimum requirement.  If there are
+problems the array can be made bigger again with no loss with another
+.B "\-\-grow \-\-size="
+command.
+
+This value cannot be used when creating a
 .B CONTAINER
-metadata such as DDF and IMSM.
+such as with DDF and IMSM metadata, though it perfectly valid when
+creating an array inside a container.
 
 .TP
-.BR \-Z ", " \-\-array-size=
+.BR \-Z ", " \-\-array\-size=
 This is only meaningful with
 .B \-\-grow
 and its effect is not persistent: when the array is stopped and
@@ -446,6 +506,17 @@ but setting the size with
 is, it is required that the array size is reduced as appropriate
 before the number of devices in the array is reduced.
 
+Before reducing the size of the array you should make sure that space
+isn't needed.  If the device holds a filesystem, you would need to
+resize the filesystem to use less space.
+
+After reducing the array size you should check that the data stored in
+the device is still available.  If the device holds a filesystem, then
+an 'fsck' of the filesystem is a minimum requirement.  If there are
+problems the array can be made bigger again with no loss with another
+.B "\-\-grow \-\-array\-size="
+command.
+
 A suffix of 'M' or 'G' can be given to indicate Megabytes or
 Gigabytes respectively.
 A value of
@@ -460,6 +531,9 @@ array is 512KB.  To ensure compatibility with earlier versions, the
 default when Building and array with no persistent metadata is 64KB.
 This is only meaningful for RAID0, RAID4, RAID5, RAID6, and RAID10.
 
+RAID4, RAID5, RAID6, and RAID10 require the chunk size to be a power
+of 2.  In any case it must be a multiple of 4KB.
+
 A suffix of 'M' or 'G' can be given to indicate Megabytes or
 Gigabytes respectively.
 
@@ -675,6 +749,13 @@ with zeros before creation the operator knows the array is
 actually clean. If that is the case, such as after running
 badblocks, this argument can be used to tell mdadm the
 facts the operator knows.
+.IP
+When an array is resized to a larger size with
+.B "\-\-grow \-\-size="
+the new space is normally resynced in that same way that the whole
+array is resynced at creation.  From Linux version 3.0,
+.B \-\-assume\-clean
+can be used with that command to avoid the automatic resync.
 
 .TP
 .BR \-\-backup\-file=
@@ -686,6 +767,31 @@ or layout.  See the GROW MODE section below on RAID\-DEVICES CHANGES.
 The file must be stored on a separate device, not on the RAID array
 being reshaped.
 
+.TP
+.BR \-\-continue
+This option is complementary to the
+.B \-\-freeze-reshape
+option for assembly. It is needed when
+.B \-\-grow
+operation is interrupted and it is not restarted automatically due to
+.B \-\-freeze-reshape
+usage during array assembly.  This option is used together with
+.BR \-G
+, (
+.BR \-\-grow
+) command and device for a pending reshape to be continued.
+All parameters required for reshape continuation will be read from array metadata.
+If initial
+.BR \-\-grow
+command had required
+.BR \-\-backup\-file=
+option to be set, continuation option will require to have exactly the same
+backup file given as well.
+.IP
+Any other parameter passed together with
+.BR \-\-continue
+option will be ignored.
+
 .TP
 .BR \-N ", " \-\-name=
 Set a
@@ -725,6 +831,13 @@ initial resync work faster).  With
 .I mdadm
 will not try to be so clever.
 
+.TP
+.BR \-o ", " \-\-readonly
+Start the array
+.B read only
+rather than read-write as normal.  No writes will be allowed to the
+array, and no resync, recovery, or reshape will be started.
+
 .TP
 .BR \-a ", " "\-\-auto{=yes,md,mdp,part,p}{NN}"
 Instruct mdadm how to create the device file if needed, possibly allocating
@@ -777,6 +890,11 @@ number, and there is no entry in /dev for that number and with a
 non-standard name.  Names that are not in 'standard' format are only
 allowed in "/dev/md/".
 
+This is meaningful with
+.B \-\-create
+or
+.BR \-\-build .
+
 .ig XX
 .\".TP
 .\".BR \-\-symlink = no
@@ -801,6 +919,28 @@ allowed in "/dev/md/".
 .\"
 .XX
 
+.TP
+.BR \-a ", " "\-\-add"
+This option can be used in Grow mode in two cases.
+
+If the target array is a Linear array, then
+.B \-\-add
+can be used to add one or more devices to the array.  They
+are simply catenated on to the end of the array.  Once added, the
+devices cannot be removed.
+
+If the
+.B \-\-raid\-disks
+option is being used to increase the number of devices in an array,
+then
+.B \-\-add
+can be used to add some extra devices to be included in the array.
+In most cases this is not needed as the extra devices can be added as
+spares first, and then the number of raid-disks can be changed.
+However for RAID0, it is not possible to add spares.  So to increase
+the number of devices in a RAID0, it is necessary to set the new
+number of devices, and to add the new devices, in the same command.
+
 .SH For assemble:
 
 .TP
@@ -920,6 +1060,8 @@ argument given to this flag can be one of
 .BR byteorder ,
 .BR devicesize ,
 .BR no\-bitmap ,
+.BR bbl ,
+.BR no-\bbl ,
 or
 .BR super\-minor .
 
@@ -1022,15 +1164,29 @@ option can be used when an array has an internal bitmap which is
 corrupt in some way so that assembling the array normally fails.  It
 will cause any internal bitmap to be ignored.
 
-.ig
+The
+.B bbl
+option will reserve space in each device for a bad block list.  This
+will be 4K in size and positioned near the end of any free space
+between the superblock and the data.
+
+The
+.B no\-bbl
+option will cause any reservation of space for a bad block list to be
+removed.  If the bad block list contains entries, this will fail, as
+removing the list could cause data corruption.
+
 .TP
-.B \-\-auto\-update\-homehost
-This flag is only meaningful with auto-assembly (see discussion below).
-In that situation, if no suitable arrays are found for this homehost,
-.I mdadm
-will rescan for any arrays at all and will assemble them and update the
-homehost to match the current host.
-..
+.BR \-\-freeze\-reshape
+Option is intended to be used in start-up scripts during initrd boot phase.
+When array under reshape is assembled during initrd phase, this option
+stops reshape after reshape critical section is being restored. This happens
+before file system pivot operation and avoids loss of file system context.
+Losing file system context would cause reshape to be broken.
+
+Reshape can be continued later using the
+.B \-\-continue
+option for the grow command.
 
 .SH For Manage mode:
 
@@ -1053,7 +1209,7 @@ will report failure if these specifiers didn't find any match.
 .BR \-a ", " \-\-add
 hot-add listed devices.
 If a device appears to have recently been part of the array
-(possibly it failed or was removed) the device is re\-added as describe
+(possibly it failed or was removed) the device is re\-added as described
 in the next point.
 If that fails or the device was never part of the array, the device is
 added as a hot-spare.
@@ -1079,12 +1235,14 @@ When used on an array that has no metadata (i.e. it was built with
 it will be assumed that bitmap-based recovery is enough to make the
 device fully consistent with the array.
 
-When
+When used with v1.x metadata,
 .B \-\-re\-add
 can be accompanied by
-.BR \-\-update=devicesize .
-See the description of this option when used in Assemble mode for an
-explanation of its use.
+.BR \-\-update=devicesize ,
+.BR \-\-update=bbl ", or"
+.BR \-\-update=no\-bbl .
+See the description of these option when used in Assemble mode for an
+explanation of their use.
 
 If the device name given is
 .B missing
@@ -1174,12 +1332,16 @@ Print details of one or more md devices.
 .TP
 .BR \-\-detail\-platform
 Print details of the platform's RAID capabilities (firmware / hardware
-topology) for a given metadata format.
+topology) for a given metadata format. If used without argument, mdadm
+will scan all controllers looking for their capabilities. Otherwise, mdadm
+will only look at the controller specified by the argument in form of an
+absolute filepath or a link, e.g.
+.IR /sys/devices/pci0000:00/0000:00:1f.2 .
 
 .TP
 .BR \-Y ", " \-\-export
 When used with
-.B \-\-detail
+.B \-\-detail , \-\-detail-platform
 or
 .BR \-\-examine ,
 output will be formatted as
@@ -1299,7 +1461,7 @@ if safe-mode handling is disabled.
 .TP
 .BR \-\-rebuild\-map ", " \-r
 Rebuild the map file
-.RB ( /var/run/mdadm/map )
+.RB ( {MAP_PATH} )
 that
 .I mdadm
 uses to help track which arrays are currently being assembled.
@@ -1445,7 +1607,7 @@ the first device given is the md device.
 In the second usage example, all devices listed are treated as md
 devices and assembly is attempted.
 In the third (where no devices are listed) all md devices that are
-listed in the configuration file are assembled.  If not arrays are
+listed in the configuration file are assembled.  If no arrays are
 described by the configuration file, then any arrays that
 can be found on unused devices will be assembled.
 
@@ -1506,7 +1668,7 @@ does not create any entries in
 but leaves that to
 .IR udev .
 It does record information in
-.B /var/run/mdadm/map
+.B {MAP_PATH}
 which will allow
 .I udev
 to choose the correct name.
@@ -1554,7 +1716,7 @@ and no devices are listed,
 will first attempt to assemble all the arrays listed in the config
 file.
 
-In no array at listed in the config (other than those marked
+If no arrays are listed in the config (other than those marked
 .BR <ignore> )
 it will look through the available devices for possible arrays and
 will try to assemble anything that it finds.  Arrays which are tagged
@@ -1600,25 +1762,13 @@ See
 .IR mdadm.conf (5)
 for further details.
 
-.ig
-If
-.I mdadm
-cannot find any array for the given host at all, and if
-.B \-\-auto\-update\-homehost
-is given, then
-.I mdadm
-will search again for any array (not just an array created for this
-host) and will assemble each assuming
-.BR \-\-update=homehost .
-This will change the host tag in the superblock so that on the next run,
-these arrays will be found without the second pass.  The intention of
-this feature is to support transitioning a set of md arrays to using
-homehost tagging.
-
-The reason for requiring arrays to be tagged with the homehost for
-auto assembly is to guard against problems that can arise when moving
-devices from one host to another.
-..
+Note: Auto assembly cannot be used for assembling and activating some
+arrays which are undergoing reshape.  In particular as the
+.B backup\-file
+cannot be given, any reshape which requires a backup-file to continue
+cannot be started by auto assembly.  An array which is growing to more
+devices and has passed the critical section can be assembled using
+auto-assembly.
 
 .SH BUILD MODE
 
@@ -1741,6 +1891,11 @@ setting.
 .\".B \-\-size
 .\"is given, the apparent size of the smallest drive given is used.
 
+If the metadata type supports it (currently only 1.x metadata), space
+will be allocated to store a bad block list.  This allows a modest
+number of bad blocks to be recorded, allowing the drive to remain in
+service while only partially functional.
+
 When creating an array within a
 .B CONTAINER
 .I mdadm
@@ -2158,31 +2313,57 @@ and then follow similar steps as above if a matching spare is found.
 The GROW mode is used for changing the size or shape of an active
 array.
 For this to work, the kernel must support the necessary change.
-Various types of growth are being added during 2.6 development,
-including restructuring a RAID5 array to have more active devices.
+Various types of growth are being added during 2.6 development.
 
-Currently the only support available is to
+Currently the supported changes include
+.IP \(bu 4
+change the "size" attribute for RAID1, RAID4, RAID5 and RAID6.
 .IP \(bu 4
-change the "size" attribute
-for RAID1, RAID5 and RAID6.
+increase or decrease the "raid\-devices" attribute of RAID0, RAID1, RAID4,
+RAID5, and RAID6.
 .IP \(bu 4
-increase or decrease the "raid\-devices" attribute of RAID1, RAID5,
-and RAID6.
-.IP \bu 4
-change the chunk-size and layout of RAID5 and RAID6.
-.IP \bu 4
-convert between RAID1 and RAID5, and between RAID5 and RAID6.
+change the chunk-size and layout of RAID0, RAID4, RAID5 and RAID6.
+.IP \(bu 4
+convert between RAID1 and RAID5, between RAID5 and RAID6, between
+RAID0, RAID4, and RAID5, and between RAID0 and RAID10 (in the near-2 mode).
 .IP \(bu 4
 add a write-intent bitmap to any array which supports these bitmaps, or
 remove a write-intent bitmap from such an array.
 .PP
 
-GROW mode is not currently supported for
-.B CONTAINERS
-or arrays inside containers.
+Using GROW on containers is currently supported only for Intel's IMSM
+container format.  The number of devices in a container can be
+increased - which affects all arrays in the container - or an array
+in a container can be converted between levels where those levels are
+supported by the container, and the conversion is on of those listed
+above.  Resizing arrays in an IMSM container with
+.B "--grow --size"
+is not yet supported.
+
+Grow functionality (e.g. expand a number of raid devices) for Intel's
+IMSM container format has an experimental status. It is guarded by the
+.B MDADM_EXPERIMENTAL
+environment variable which must be set to '1' for a GROW command to
+succeed.
+This is for the following reasons:
+
+.IP 1.
+Intel's native IMSM check-pointing is not fully tested yet.
+This can causes IMSM incompatibility during the grow process: an array
+which is growing cannot roam between Microsoft Windows(R) and Linux
+systems.
+
+.IP 2.
+Interrupting a grow operation is not recommended, because it
+has not been fully tested for Intel's IMSM container format yet.
+
+.PP
+Note: Intel's native checkpointing doesn't use
+.B --backup-file
+option and it is transparent for assembly feature.
 
 .SS SIZE CHANGES
-Normally when an array is built the "size" it taken from the smallest
+Normally when an array is built the "size" is taken from the smallest
 of the drives.  If all the small drives in an arrays are, one at a
 time, removed and replaced with larger drives, then you could have an
 array of large drives with only a small amount used.  In this
@@ -2192,12 +2373,16 @@ space to start being used.  If the size is increased in this way, a
 are synchronised.
 
 Note that when an array changes size, any filesystem that may be
-stored in the array will not automatically grow to use the space.  The
-filesystem will need to be explicitly told to use the extra space.
+stored in the array will not automatically grow or shrink to use or
+vacate the space.  The
+filesystem will need to be explicitly told to use the extra space
+after growing, or to reduce its size
+.B prior
+to shrinking the array.
 
 Also the size of an array cannot be changed while it has an active
 bitmap.  If an array has a bitmap, it must be removed before the size
-can be changed. Once the change it complete a new bitmap can be created.
+can be changed. Once the change is complete a new bitmap can be created.
 
 .SS RAID\-DEVICES CHANGES
 
@@ -2221,9 +2406,20 @@ increase the number of devices in a RAID5 safely, including restarting
 an interrupted "reshape".  From 2.6.31, the Linux Kernel is able to
 increase or decrease the number of devices in a RAID5 or RAID6.
 
+From 2.6.35, the Linux Kernel is able to convert a RAID0 in to a RAID4
+or RAID5.
+.I mdadm
+uses this functionality and the ability to add
+devices to a RAID4 to allow devices to be added to a RAID0.  When
+requested to do this,
+.I mdadm
+will convert the RAID0 to a RAID4, add the necessary disks and make
+the reshape happen, and then convert the RAID4 back to RAID0.
+
 When decreasing the number of devices, the size of the array will also
 decrease.  If there was data in the array, it could get destroyed and
-this is not reversible.  To help prevent accidents,
+this is not reversible, so you should firstly shrink the filesystem on
+the array to fit within the new size.  To help prevent accidents,
 .I mdadm
 requires that the size of the array be decreased first with
 .BR "mdadm --grow --array-size" .
@@ -2362,8 +2558,8 @@ must match one of the names or patterns in a
 line.
 
 .IP +
-Does the device have a valid md superblock.  If a specific metadata
-version is request with
+Does the device have a valid md superblock?  If a specific metadata
+version is requested with
 .B \-\-metadata
 or
 .B \-e
@@ -2394,13 +2590,10 @@ is not able to positively identify the array as belonging to the
 current host, the device will be rejected.
 ..
 
+.PP
 .I mdadm
 keeps a list of arrays that it has partially assembled in
-.B /var/run/mdadm/map
-(or
-.B /var/run/mdadm.map
-if the directory doesn't exist.  Or maybe even
-.BR /dev/.mdadm.map ).
+.BR {MAP_PATH} .
 If no array exists which matches
 the metadata on the new device,
 .I mdadm
@@ -2544,12 +2737,12 @@ and assemble
 .B /dev/md0
 out of all such devices with a RAID superblock with a minor number of 0.
 
-.B "  mdadm \-\-monitor \-\-scan \-\-daemonise > /var/run/mdadm"
+.B "  mdadm \-\-monitor \-\-scan \-\-daemonise > /run/mdadm/mon.pid"
 .br
 If config file contains a mail address or alert program, run mdadm in
 the background in monitor mode monitoring all md devices.  Also write
 pid of mdadm daemon to
-.BR /var/run/mdadm .
+.BR /run/mdadm/mon.pid .
 
 .B "  mdadm \-Iq /dev/somedevice"
 .br
@@ -2566,7 +2759,7 @@ can be started.
 Any devices which are components of /dev/md4 will be marked as faulty
 and then remove from the array.
 
-.B "  mdadm --grow /dev/md4 --level=6 --backup-file=/root/backup-md4
+.B "  mdadm --grow /dev/md4 --level=6 --backup-file=/root/backup-md4"
 .br
 The array
 .B /dev/md4
@@ -2627,21 +2820,10 @@ they contain MD super block, and gives identifying information
 .BR mdadm.conf (5)
 for more details.
 
-.SS /var/run/mdadm/map
+.SS {MAP_PATH}
 When
 .B \-\-incremental
 mode is used, this file gets a list of arrays currently being created.
-If
-.B /var/run/mdadm
-does not exist as a directory, then
-.B /var/run/mdadm.map
-is used instead.  If
-.B /var/run
-is not available (as may be the case during early boot),
-.B /dev/.mdadm.map
-is used on the basis that
-.B /dev
-is usually available very early in boot.
 
 .SH DEVICE NAMES
 
@@ -2714,7 +2896,7 @@ configuration file at all.
 For further information on mdadm usage, MD and the various levels of
 RAID, see:
 .IP
-.B http://linux\-raid.osdl.org/
+.B http://raid.wiki.kernel.org/
 .PP
 (based upon Jakob \(/Ostergaard's Software\-RAID.HOWTO)
 .\".PP