Linear and RAID levels 0/1/4/5/6,
changing the RAID level between 0, 1, 5, and 6, and between 0 and 10,
changing the chunk size and layout for RAID 0,4,5,6,10 as well as adding or
-removing a write-intent bitmap.
+removing a write-intent bitmap and changing the array's consistency policy.
.TP
.B "Incremental Assembly"
restores the apparent size of the array to be whatever the real
amount of available space is.
+Clustered arrays do not support this parameter yet.
+
.TP
.BR \-c ", " \-\-chunk=
Specify chunk size of kilobytes. The default when creating an
Start the array
.B read only
rather than read-write as normal. No writes will be allowed to the
-array, and no resync, recovery, or reshape will be started.
+array, and no resync, recovery, or reshape will be started. It works with
+Create, Assemble, Manage and Misc mode.
.TP
.BR \-a ", " "\-\-auto{=yes,md,mdp,part,p}{NN}"
For RAID5 only, Partial Parity Log is used to close the write hole and
eliminate resync. PPL is stored in the metadata region of RAID member drives,
no additional journal drive is needed.
+
+.PP
+Can be used with \-\-grow to change the consistency policy of an active array
+in some cases. See CONSISTENCY POLICY CHANGES below.
.RE
The
.B byteorder
option allows arrays to be moved between machines with different
-byte-order.
+byte-order, such as from a big-endian machine like a Sparc or some
+MIPS machines, to a little-endian x86_64 machine.
When assembling such an array for the first time after a move, giving
.B "\-\-update=byteorder"
will cause
.TP
.BR \-\-add-journal
-Recreate journal for RAID-4/5/6 array that lost a journal device. In the
-current implementation, this command cannot add a journal to an array
-that had a failed journal. To avoid interrupting on-going write opertions,
+Add journal to an existing array, or recreate journal for RAID-4/5/6 array
+that lost a journal device. To avoid interrupting on-going write opertions,
.B \-\-add-journal
only works for array in Read-Only state.
the block where the superblock would be is overwritten even if it
doesn't appear to be valid.
+.B Note:
+Be careful to call \-\-zero\-superblock with clustered raid, make sure
+array isn't used or assembled in other cluster node before execute it.
+
.TP
.B \-\-kill\-subarray=
If the device is a container and the argument to \-\-kill\-subarray
can be added later with
.BR "\-\-grow \-\-bitmap=internal" .
-If the metadata type supports it (currently only 1.x metadata), space
-will be allocated to store a bad block list. This allows a modest
+If the metadata type supports it (currently only 1.x and IMSM metadata),
+space will be allocated to store a bad block list. This allows a modest
number of bad blocks to be recorded, allowing the drive to remain in
service while only partially functional.
.TP
.B \-\-readonly
-start the array readonly \(em not supported yet.
+start the array in readonly mode.
.SH MANAGE MODE
.HP 12
.IP \(bu 4
add a write-intent bitmap to any array which supports these bitmaps, or
remove a write-intent bitmap from such an array.
+.IP \(bu 4
+change the array's consistency policy.
.PP
Using GROW on containers is currently supported only for Intel's IMSM
bitmap. If an array has a bitmap, it must be removed before the size
can be changed. Once the change is complete a new bitmap can be created.
+.PP
+Note:
+.B "--grow --size"
+is not yet supported for external file bitmap.
+
.SS RAID\-DEVICES CHANGES
A RAID1 array can work with any number of devices from 1 upwards
in a filesystem that is on the RAID array being affected, the system
will deadlock. The bitmap must be on a separate filesystem.
+.SS CONSISTENCY POLICY CHANGES
+
+The consistency policy of an active array can be changed by using the
+.B \-\-consistency\-policy
+option in Grow mode. Currently this works only for the
+.B ppl
+and
+.B resync
+policies and allows to enable or disable the RAID5 Partial Parity Log (PPL).
+
.SH INCREMENTAL MODE
.HP 12
usually provided by a
.I udev
rules mentioning
-.BR ${DEVLINKS} .
+.BR $env{DEVLINKS} .
.IP +