]> git.ipfire.org Git - thirdparty/mdadm.git/blobdiff - mdadm.conf.5
mdcheck: Log when done
[thirdparty/mdadm.git] / mdadm.conf.5
index c142a2fe9bedd64eed4d03a4fcc66185cf0fe8b6..27dbab18455d145790e502e101b1a02947ef7d13 100644 (file)
@@ -25,6 +25,16 @@ space (space, tab, or newline).
 Any word that beings with a hash sign (#) starts a comment and that
 word together with the remainder of the line is ignored.
 
+Spaces can be included in a word using quotation characters.  Either
+single quotes
+.RB ( ' )
+or double quotes (\fB"\fP)
+may be used.  All the characters from one quotation character to
+next identical character are protected and will not be used to
+separate words to start new quoted strings.  To include a single quote
+it must be between double quotes.  To include a double quote it must
+be between single quotes.
+
 Any line that starts with white space (space or tab) is treated as
 though it were a continuation of the previous line.
 
@@ -138,11 +148,11 @@ created as /dev/mdX, then the minor number X is stored.
 The value is a comma separated list of device names or device name
 patterns.
 Only devices with names which match one entry in the list will be used
-to assemble the array.  Note that the devices 
+to assemble the array.  Note that the devices
 listed there must also be listed on a DEVICE line.
 .TP
 .B level=
-The value is a raid level.  This is not normally used to
+The value is a RAID level.  This is not normally used to
 identify an array, but is supported so that the output of
 
 .B "mdadm \-\-examine \-\-scan"
@@ -246,8 +256,8 @@ mode (and was given the
 .B \-\-scan
 option).  There should only be one
 .B MAILADDR
-line and it should have only one address.
-
+line and it should have only one address.  Any subsequent addresses
+are silently ignored.
 
 .TP
 .B MAILFROM
@@ -283,8 +293,8 @@ line and it should be give only one program.
 .B CREATE
 The
 .B create
-line gives default values to be used when creating arrays and device entries for
-arrays.
+line gives default values to be used when creating arrays, new members
+of arrays, and device entries for arrays.
 These include:
 
 .RS 4
@@ -329,6 +339,42 @@ or
 Give
 .B symlinks=no
 to suppress this symlink creation.
+
+.TP
+.B names=yes
+Since Linux 2.6.29 it has been possible to create
+.B md
+devices with a name like
+.B md_home
+rather than just a number, like
+.BR md3 .
+.I mdadm
+will use the numeric alternative by default as other tools that interact
+with md arrays may expect only numbers.
+If
+.B names=yes
+is given in
+.I mdadm.conf
+then
+.I mdadm
+will use a name when appropriate.
+If
+.B names=no
+is given, then non-numeric
+.I md
+device names will not be used even if the default changes in a future
+release of
+.IR mdadm .
+
+.TP
+.B bbl=no
+By default,
+.I mdadm
+will reserve space for a bad block list (bbl) on all devices
+included in or added to any array that supports them.  Setting
+.B bbl=no
+will prevent this, so newly added devices will not have a bad
+block log.
 .RE
 
 .TP
@@ -361,7 +407,9 @@ is given it is also possible to give an explicit name which will be
 used when creating arrays.  This is the only case when there can be
 more that one other word on the
 .B HOMEHOST
-line.
+line.  If there are other words, or other
+.B HOMEHOST
+lines, they are silently ignored.
 
 If
 .B <none>
@@ -425,9 +473,14 @@ The known metadata types are
 .BR ddf ,
 .BR imsm .
 
+.B AUTO
+should be given at most once.  Subsequent lines are silently ignored.
+Thus an earlier config file in a config directory will over-ride
+the setting in a later config file.
+
 .TP
 .B POLICY
-This is used to specify what automatic behavior is allowed on devices 
+This is used to specify what automatic behavior is allowed on devices
 newly appearing in the system and provides a way of marking spares that can
 be moved to other arrays as well as the migration domains.
 .I Domain
@@ -439,7 +492,7 @@ A device may belong to several domains. The domain of an array is a union
 of domains of all devices in that array.  A spare can be automatically
 moved from one array to another if the set of the destination array's
 .I domains
-ppcontains all the
+contains all the
 .I domains
 of the new disk or if both arrays have the same
 .IR spare-group .
@@ -448,7 +501,7 @@ To update hot plug configuration it is necessary to execute
 .B mdadm \-\-udev\-rules
 command after changing the config file
 
-Key words used in the
+Keywords used in the
 .I POLICY
 line and supported values are:
 
@@ -465,13 +518,14 @@ file glob matching anything from
 .B /dev/disk/by-path
 .TP
 .B type=
-either 
+either
 .B disk
 or
 .BR part .
 .TP
 .B action=
 include, re-add, spare, spare-same-slot, or force-spare
+.TP
 .B auto=
 yes, no, or homehost.
 
@@ -490,9 +544,12 @@ is irrelevant to the end result.
 .B include
 allows adding a disk to an array if metadata on that disk matches that array
 .TP
-.B re-add
+.B re\-add
 will include the device in the array if it appears to be a current member
-or a member that was recently removed
+or a member that was recently removed and the array has a
+write-intent-bitmap to allow the
+.B re\-add
+functionality.
 .TP
 .B spare
 as above and additionally: if the device is bare it can
@@ -504,10 +561,52 @@ as above and additionally if given slot was used by an array that went
 degraded recently and the device plugged in has no metadata then it will
 be automatically added to that array (or it's container)
 .TP
-.B force-spare
+.B force\-spare
 as above and the disk will become a spare in remaining cases
 .RE
 
+.TP
+.B PART-POLICY
+This is similar to
+.B POLICY
+and accepts the same keyword assignments.  It allows a consistent set
+of policies to applied to each of the partitions of a device.
+
+A
+.B PART-POLICY
+line should set
+.I type=disk
+and identify the path to one or more disk devices.  Each partition on
+these disks will be treated according to the
+.I action=
+setting  from this line.  If a
+.I domain
+is set in the line, then the domain associated with each patition will
+be based on the domain, but with
+.RB \(dq -part N\(dq
+appended, when N is the partition number for the partition that was
+found.
+
+.TP
+.B SYSFS
+The SYSFS line lists custom values of MD device's sysfs attributes which will be
+stored in sysfs after the array is assembled. Multiple lines are allowed and each
+line has to contain the uuid or the name of the device to which it relates.
+.RS 4
+.TP
+.B uuid=
+hexadecimal identifier of MD device. This has to match the uuid stored in the
+superblock.
+.TP
+.B name=
+name of the MD device as was given to
+.I mdadm
+when the array was created. It will be ignored if
+.B uuid
+is not empty.
+.TP
+.RS 7
+
 .SH EXAMPLE
 DEVICE /dev/sd[bcdjkl]1
 .br
@@ -547,6 +646,10 @@ ARRAY /dev/md/home UUID=9187a482:5dde19d9:eea3cc4a:d646ab8b
 .br
            auto=part
 .br
+# The name of this array contains a space.
+.br
+ARRAY /dev/md9 name='Data Storage'
+.sp
 POLICY domain=domain1 metadata=imsm path=pci-0000:00:1f.2-scsi-*
 .br
            action=spare
@@ -573,9 +676,13 @@ CREATE group=system mode=0640 auto=part\-8
 .br
 HOMEHOST <system>
 .br
-AUTO +1.x homehost -all
+AUTO +1.x homehost \-all
+.br
+SYSFS name=/dev/md/raid5 group_thread_cnt=4 sync_speed_max=1000000
+.br
+SYSFS uuid=bead5eb6:31c17a27:da120ba2:7dfda40d group_thread_cnt=4
+sync_speed_max=1000000
 
 .SH SEE ALSO
 .BR mdadm (8),
 .BR md (4).
-