This patch adds the warning message when x8-type device
is used with IMSM metadata. x8 device is a special
NVMe drive - two of them on a single PCIe card.
This card could be a single point of failure for
RAID levels different than RAID0. x8 devices have
serial number ending with "-A/-B" or "-1/-2".

Signed-off-by: Pawel Baldysiak <pawel.baldysiak@intel.com>
Reviewed-by: Artur Paszkiewicz <artur.paszkiewicz@intel.com>
Signed-off-by: Jes Sorensen <Jes.Sorensen@redhat.com>
super-intel.c

index e501b6fd30ed682c22c17467ab9cd7f2fcade3f8..81d8e8cc4a006bcf1578b29678ae35e28c55ec48 100644 (file)
@@ -5137,9 +5137,53 @@ static int add_to_super_imsm(struct supertype *st, mdu_disk_info_t *dk,
        rv = imsm_read_serial(fd, devname, dd->serial);
        if (rv) {
                pr_err("failed to retrieve scsi serial, aborting\n");
+               if (dd->devname)
+                       free(dd->devname);
                free(dd);
                abort();
        }
+       if (super->hba && ((super->hba->type == SYS_DEV_NVME) ||
+          (super->hba->type == SYS_DEV_VMD))) {
+               int i;
+               char *devpath = diskfd_to_devpath(fd);
+               char controller_path[PATH_MAX];
+
+               if (!devpath) {
+                       pr_err("failed to get devpath, aborting\n");
+                       if (dd->devname)
+                               free(dd->devname);
+                       free(dd);
+                       return 1;
+               }
+
+               snprintf(controller_path, PATH_MAX-1, "%s/device", devpath);
+               free(devpath);
+
+               if (devpath_to_vendor(controller_path) == 0x8086) {
+                       /*
+                        * If Intel's NVMe drive has serial ended with
+                        * "-A","-B","-1" or "-2" it means that this is "x8"
+                        * device (double drive on single PCIe card).
+                        * User should be warned about potential data loss.
+                        */
+                       for (i = MAX_RAID_SERIAL_LEN-1; i > 0; i--) {
+                               /* Skip empty character at the end */
+                               if (dd->serial[i] == 0)
+                                       continue;
+
+                               if (((dd->serial[i] == 'A') ||
+                                  (dd->serial[i] == 'B') ||
+                                  (dd->serial[i] == '1') ||
+                                  (dd->serial[i] == '2')) &&
+                                  (dd->serial[i-1] == '-'))
+                                       pr_err("\tThe action you are about to take may put your data at risk.\n"
+                                               "\tPlease note that x8 devices may consist of two separate x4 devices "
+                                               "located on a single PCIe port.\n"
+                                               "\tRAID 0 is the only supported configuration for this type of x8 device.\n");
+                               break;
+                       }
+               }
+       }
 