]> git.ipfire.org Git - thirdparty/systemd.git/blob - man/systemd.net-naming-scheme.xml
man: fix link markup
[thirdparty/systemd.git] / man / systemd.net-naming-scheme.xml
1 <?xml version='1.0'?>
2 <!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
3 "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">
4 <!-- SPDX-License-Identifier: LGPL-2.1+ -->
5
6 <refentry id="systemd.net-naming-scheme">
7 <refentryinfo>
8 <title>systemd.net-naming-scheme</title>
9 <productname>systemd</productname>
10 </refentryinfo>
11
12 <refmeta>
13 <refentrytitle>systemd.net-naming-scheme</refentrytitle>
14 <manvolnum>7</manvolnum>
15 </refmeta>
16
17 <refnamediv>
18 <refname>systemd.net-naming-scheme</refname>
19 <refpurpose>Network device naming schemes</refpurpose>
20 </refnamediv>
21
22 <refsect1>
23 <title>Description</title>
24
25 <para>Network interfaces names and MAC addresses may be generated based on certain stable interface
26 attributes. This is possible when there is enough information about the device to generate those
27 attributes and the use of this information is configured. This page describes interface naming, i.e. what
28 possible names may be generated. Those names are generated by the
29 <citerefentry><refentrytitle>systemd-udevd.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>
30 builtin <command>net_id</command> and exported as udev properties
31 (<varname>ID_NET_NAME_ONBOARD=</varname>, <varname>ID_NET_LABEL_ONBOARD=</varname>,
32 <varname>ID_NET_NAME_PATH=</varname>, <varname>ID_NET_NAME_SLOT=</varname>).</para>
33
34 <para>Names and MAC addresses are derived from various stable device metadata attributes. Newer versions
35 of udev take more of these attributes into account, improving (and thus possibly changing) the names and
36 addresses used for the same devices. Different versions of those generation rules are called "naming
37 schemes". The default naming scheme is chosen at compilation time. Usually this will be the latest
38 implemented version, but it is also possible to set one of the older versions to preserve
39 compatibility. This may be useful for example for distributions, which may introduce new versions of
40 systemd in stable releases without changing the naming scheme. The naming scheme may also be overridden
41 using the <varname>net.naming-scheme=</varname> kernel command line switch, see
42 <citerefentry><refentrytitle>systemd-udevd.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>.
43 Available naming schemes are described below.</para>
44
45 <para>After the udev properties have been generated, appropriate udev rules may be used to actually rename
46 devices based on those properties. See the description of <varname>NamePolicy=</varname> and
47 <varname>MACAddressPolicy=</varname> in
48 <citerefentry><refentrytitle>systemd.link</refentrytitle><manvolnum>5</manvolnum></citerefentry>.</para>
49
50 <para>Note that while the concept of network interface naming schemes is primarily relevant in the
51 context of <filename>systemd-udevd.service</filename>, the
52 <citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry>
53 container manager also takes it into account when naming network interfaces, see below.</para>
54 </refsect1>
55
56 <refsect1>
57 <title>Naming</title>
58
59 <para>All names start with a two-character prefix that signifies the interface type.</para>
60
61 <table>
62 <title>Two character prefixes based on the type of interface</title>
63
64 <tgroup cols='2'>
65 <thead>
66 <row>
67 <entry>Prefix</entry>
68 <entry>Description</entry>
69 </row>
70 </thead>
71 <tbody>
72 <row>
73 <entry><constant>en</constant></entry>
74 <entry>Ethernet</entry>
75 </row>
76 <row>
77 <entry><constant>ib</constant></entry>
78 <entry>InfiniBand</entry>
79 </row>
80 <row>
81 <entry><constant>sl</constant></entry>
82 <entry>Serial line IP (slip)</entry>
83 </row>
84 <row>
85 <entry><constant>wl</constant></entry>
86 <entry>Wireless local area network (WLAN)</entry>
87 </row>
88 <row>
89 <entry><constant>ww</constant></entry>
90 <entry>Wireless wide area network (WWAN)</entry>
91 </row>
92 </tbody>
93 </tgroup>
94 </table>
95
96 <para>The udev <command>net_id</command> builtin exports the following udev device properties:</para>
97
98 <variablelist>
99 <varlistentry>
100 <term><varname>ID_NET_NAME_ONBOARD=<replaceable>prefix</replaceable><constant>o</constant><replaceable>number</replaceable></varname></term>
101
102 <listitem><para>This name is set based on the numeric ordering information given by the firmware
103 for on-board devices. The name consists of the prefix, letter <constant>o</constant>, and a number
104 specified by the firmware. This is only available for PCI devices.</para>
105 </listitem>
106 </varlistentry>
107
108 <varlistentry>
109 <term><varname>ID_NET_LABEL_ONBOARD=<replaceable>prefix</replaceable> <replaceable>label</replaceable></varname></term>
110
111 <listitem><para>This property is set based on textual label given by the firmware for on-board
112 devices. The name consists of the prefix concatenated with the label. This is only available for
113 PCI devices.
114 </para>
115 </listitem>
116 </varlistentry>
117
118 <varlistentry>
119 <term><varname>ID_NET_NAME_MAC=<replaceable>prefix</replaceable><constant>x</constant><replaceable>AABBCCDDEEFF</replaceable></varname></term>
120
121 <listitem><para>This name consists of the prefix, letter <constant>x</constant>, and 12 hexadecimal
122 digits of the MAC address. It is available if the device has a fixed MAC address. Because this name
123 is based on an attribute of the card itself, it remains "stable" when the device is moved (even
124 between machines), but will change when the hardware is replaced.</para>
125 </listitem>
126 </varlistentry>
127
128 <varlistentry>
129 <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]</varname></term>
130 <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable><constant>v</constant><replaceable>slot</replaceable></varname></term>
131 <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>b</constant><replaceable>number</replaceable></varname></term>
132 <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>u</constant><replaceable>port</replaceable>…[<constant>c</constant><replaceable>config</replaceable>][<constant>i</constant><replaceable>interface</replaceable>]</varname></term>
133 <term><varname>ID_NET_NAME_SLOT=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>v</constant><replaceable>slot</replaceable></varname></term>
134
135 <listitem><para>This property describes the slot position. Different schemes are used depending on
136 the bus type, as described in the table below. In case of USB, BCMA, and SR-VIO devices, the full
137 name consists of the prefix, PCI slot identifier, and USB or BCMA or SR-VIO slot identifier. The
138 first two parts are denoted as "…" in the table below.</para>
139
140 <table>
141 <title>Slot naming schemes</title>
142
143 <tgroup cols='2'>
144 <thead>
145 <row>
146 <entry>Format</entry>
147 <entry>Description</entry>
148 </row>
149 </thead>
150
151 <tbody>
152 <row>
153 <entry><replaceable>prefix</replaceable> [<constant>P</constant><replaceable>domain</replaceable><constant>s</constant><replaceable>slot</replaceable> [<constant>f</constant><replaceable>function</replaceable>] [<constant>n</constant><replaceable>port_name</replaceable> | <constant>d</constant><replaceable>dev_port</replaceable>]</entry>
154 <entry>PCI slot number</entry>
155 </row>
156
157 <row>
158 <entry><replaceable>prefix</replaceable> <constant>v</constant><replaceable>slot</replaceable></entry>
159 <entry>VIO slot number (IBM PowerVM)</entry>
160 </row>
161
162 <row>
163 <entry>… <constant>b</constant><replaceable>number</replaceable></entry>
164 <entry>Broadcom bus (BCMA) core number</entry>
165 </row>
166
167 <row>
168 <entry>… <constant>u</constant><replaceable>port</replaceable>… [<constant>c</constant><replaceable>config</replaceable>] [<constant>i</constant><replaceable>interface</replaceable>]</entry>
169 <entry>USB port number chain</entry>
170 </row>
171
172 <row>
173 <entry>… <constant>v</constant><replaceable>slot</replaceable></entry>
174 <entry>SR-VIO slot number</entry>
175 </row>
176 </tbody>
177 </tgroup>
178 </table>
179
180 <para>The PCI domain is only prepended when it is not 0. All multi-function PCI devices will carry
181 the <constant>f<replaceable>function</replaceable></constant> number in the device name, including
182 the function 0 device. For non-multi-function devices, the number is suppressed if 0. The port name
183 <replaceable>port_name</replaceable> is used, or the port number
184 <constant>d</constant><replaceable>dev_port</replaceable> if the name is not known.</para>
185
186 <para>For BCMA devices, the core number is suppressed when 0.</para>
187
188 <para>For USB devices the full chain of port numbers of hubs is composed. If the name gets longer
189 than the maximum number of 15 characters, the name is not exported. The usual USB configuration
190 number 1 and interface number 0 values are suppressed.</para>
191
192 <para>SR-IOV virtual devices are named based on the name of the parent interface, with a suffix of
193 <constant>v</constant> and the virtual device number, with any leading zeros removed. The bus
194 number is ignored.</para>
195 </listitem>
196 </varlistentry>
197
198 <varlistentry>
199 <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>c</constant><replaceable>bus_id</replaceable></varname></term>
200 <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>a</constant><replaceable>vendor</replaceable><replaceable>model</replaceable><constant>i</constant><replaceable>instance</replaceable></varname></term>
201 <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable><constant>i</constant><replaceable>address</replaceable><constant>n</constant><replaceable>port_name</replaceable></varname></term>
202 <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]</varname></term>
203 <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>b</constant><replaceable>number</replaceable></varname></term>
204 <term><varname>ID_NET_NAME_PATH=<replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>u</constant><replaceable>port</replaceable>…[<constant>c</constant><replaceable>config</replaceable>][<constant>i</constant><replaceable>interface</replaceable>]</varname></term>
205
206 <listitem><para>This property describes the device installation location. Different schemes are
207 used depending on the bus type, as described in the table below. For BCMA and USB devices, PCI path
208 information must known, and the full name consists of the prefix, PCI slot identifier, and USB or
209 BCMA location. The first two parts are denoted as "…" in the table below.</para>
210
211 <table>
212 <title>Path naming schemes</title>
213
214 <tgroup cols='2'>
215 <thead>
216 <row>
217 <entry>Format</entry>
218 <entry>Description</entry>
219 </row>
220 </thead>
221
222 <tbody>
223 <row>
224 <entry><replaceable>prefix</replaceable> <constant>c</constant><replaceable>bus_id</replaceable></entry>
225 <entry>CCW or grouped CCW device identifier</entry>
226 </row>
227
228 <row>
229 <entry><replaceable>prefix</replaceable> <constant>a</constant><replaceable>vendor</replaceable> <replaceable>model</replaceable> <constant>i</constant><replaceable>instance</replaceable></entry>
230 <entry>ACPI path names for ARM64 platform devices</entry>
231 </row>
232
233 <row>
234 <entry><replaceable>prefix</replaceable> <constant>i</constant><replaceable>address</replaceable> <constant>n</constant><replaceable>port_name</replaceable></entry>
235 <entry>Netdevsim (simulated networking device) device number and port name</entry>
236 </row>
237
238 <row>
239 <entry><replaceable>prefix</replaceable> [<constant>P</constant><replaceable>domain</replaceable><constant>p</constant><replaceable>bus</replaceable> <constant>s</constant><replaceable>slot</replaceable> [<constant>f</constant><replaceable>function</replaceable>] [<constant>n</constant><replaceable>phys_port_name</replaceable> | <constant>d</constant><replaceable>dev_port</replaceable>]</entry>
240 <entry>PCI geographical location</entry>
241 </row>
242
243 <row>
244 <entry>… <constant>b</constant><replaceable>number</replaceable></entry>
245 <entry>Broadcom bus (BCMA) core number</entry>
246 </row>
247
248 <row>
249 <entry>… <constant>u</constant><replaceable>port</replaceable>… [<constant>c</constant><replaceable>config</replaceable>] [<constant>i</constant><replaceable>interface</replaceable>]</entry>
250 <entry>USB port number chain</entry>
251 </row>
252
253 </tbody>
254 </tgroup>
255 </table>
256
257 <para>CCW and grouped CCW devices are found in IBM System Z mainframes. Any leading zeros and
258 dots are suppressed.</para>
259
260 <para>For PCI, BCMA, and USB devices, the same rules as described above for slot naming are
261 used.</para>
262 </listitem>
263 </varlistentry>
264 </variablelist>
265 </refsect1>
266
267 <refsect1>
268 <title>History</title>
269
270 <para>The following "naming schemes" have been defined:</para>
271
272 <variablelist>
273 <varlistentry>
274 <term><constant>v238</constant></term>
275
276 <listitem><para>This is the naming scheme that was implemented in systemd 238.</para></listitem>
277 </varlistentry>
278
279 <varlistentry>
280 <term><constant>v239</constant></term>
281
282 <listitem><para>Naming was changed for virtual network interfaces created with SR-IOV and NPAR and
283 for devices where the PCI network controller device does not have a slot number associated.</para>
284
285 <para>SR-IOV virtual devices are named based on the name of the parent interface, with a suffix of
286 <literal>v<replaceable>port</replaceable></literal>, where <replaceable>port</replaceable> is the
287 virtual device number. Previously those virtual devices were named as if completely independent.
288 </para>
289
290 <para>The ninth and later NPAR virtual devices are named following the scheme used for the first
291 eight NPAR partitions. Previously those devices were not renamed and the kernel default
292 ("eth<replaceable>N</replaceable>") was used.</para>
293
294 <para>Names are also generated for PCI devices where the PCI network controller device does not
295 have an associated slot number itself, but one of its parents does. Previously those devices were
296 not renamed and the kernel default was used.</para>
297 </listitem>
298 </varlistentry>
299
300 <varlistentry>
301 <term><constant>v240</constant></term>
302
303 <listitem><para>The <literal>ib</literal> prefix and stable names for infiniband devices are
304 introduced. Previously those devices were not renamed.</para>
305
306 <para>The ACPI index field (used in <varname>ID_NET_NAME_ONBOARD=</varname>) is now also used when
307 0.</para>
308
309 <para>A new naming policy <varname>NamePolicy=keep</varname> was introduced. With this policy, if
310 the network device name was already set by userspace, the device will not be renamed
311 again. Previously, this naming policy applied implicitly, and now it must be explicitly
312 requested. Effectively, this means that network devices will be renamed according to the
313 configuration, even if they have been renamed already, if <constant>keep</constant> is not
314 specified as the naming policy in the <filename index="false">.link</filename> file. See
315 <citerefentry><refentrytitle>systemd.link</refentrytitle><manvolnum>5</manvolnum></citerefentry>
316 for a description of <varname>NamePolicy=</varname>.</para></listitem>
317 </varlistentry>
318
319 <varlistentry>
320 <term><constant>v241</constant></term>
321
322 <listitem><para><option>MACAddressPolicy=persistent</option> was extended to set MAC addresses
323 based on the device name. Previously addresses were only based on the
324 <varname index="false">ID_NET_NAME_*</varname> attributes, which meant that interface names would
325 never be generated for virtual devices. Now a persistent address will be generated for most
326 devices, including in particular bridges.</para>
327
328 <para>Note: when userspace does not set a MAC address for a bridge device, the kernel will
329 initially assign a random address, and then change it when the first device is enslaved to the
330 bridge. With this naming policy change, bridges get a persistent MAC address based on the bridge
331 name instead of the first enslaved device.</para></listitem>
332 </varlistentry>
333
334 <varlistentry>
335 <term><constant>v243</constant></term>
336
337 <listitem><para>Support for renaming netdevsim (simulated networking) devices was added. Previously
338 those devices were not renamed.</para>
339
340 <para>Previously two-letter interface type prefix was prepended to
341 <varname>ID_NET_LABEL_ONBOARD=</varname>. This is not done anymore.</para></listitem>
342 </varlistentry>
343
344 <varlistentry>
345 <term><constant>v245</constant></term>
346
347 <listitem><para>When
348 <citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry>
349 derives the name for the host side of the network interface created with
350 <option>--network-veth</option> from the container name it previously simply truncated the result
351 at 15 characters if longer (since that's the maximum length for network interface names). From now
352 on, for any interface name that would be longer than 15 characters the last 4 characters are set to
353 a 24bit hash value of the full interface name. This way network interface name collisions between
354 multiple similarly named containers (who only differ in container name suffix) should be less
355 likely (but still possible, since the 24bit hash value is very small).</para></listitem>
356 </varlistentry>
357 </variablelist>
358
359 <para>Note that <constant>latest</constant> may be used to denote the latest scheme known (to this
360 particular version of systemd).</para>
361 </refsect1>
362
363 <refsect1>
364 <title>Examples</title>
365
366 <example>
367 <title>Using <command>udevadm test-builtin</command> to display device properties</title>
368
369 <programlisting>$ udevadm test-builtin net_id /sys/class/net/enp0s31f6
370 ...
371 Using default interface naming scheme 'v243'.
372 ID_NET_NAMING_SCHEME=v243
373 ID_NET_NAME_MAC=enx54ee75cb1dc0
374 ID_OUI_FROM_DATABASE=Wistron InfoComm(Kunshan)Co.,Ltd.
375 ID_NET_NAME_PATH=enp0s31f6
376 ...</programlisting>
377 </example>
378
379 <example>
380 <title>PCI Ethernet card with firmware index "1"</title>
381
382 <programlisting>ID_NET_NAME_ONBOARD=eno1
383 ID_NET_NAME_ONBOARD_LABEL=Ethernet Port 1
384 </programlisting>
385 </example>
386
387 <example>
388 <title>PCI Ethernet card in hotplug slot with firmware index number</title>
389
390 <programlisting># /sys/devices/pci0000:00/0000:00:1c.3/0000:05:00.0/net/ens1
391 ID_NET_NAME_MAC=enx000000000466
392 ID_NET_NAME_PATH=enp5s0
393 ID_NET_NAME_SLOT=ens1</programlisting>
394 </example>
395
396 <example>
397 <title>PCI Ethernet multi-function card with 2 ports</title>
398
399 <programlisting># /sys/devices/pci0000:00/0000:00:1c.0/0000:02:00.0/net/enp2s0f0
400 ID_NET_NAME_MAC=enx78e7d1ea46da
401 ID_NET_NAME_PATH=enp2s0f0
402
403 # /sys/devices/pci0000:00/0000:00:1c.0/0000:02:00.1/net/enp2s0f1
404 ID_NET_NAME_MAC=enx78e7d1ea46dc
405 ID_NET_NAME_PATH=enp2s0f1</programlisting>
406 </example>
407
408 <example>
409 <title>PCI WLAN card</title>
410
411 <programlisting># /sys/devices/pci0000:00/0000:00:1c.1/0000:03:00.0/net/wlp3s0
412 ID_NET_NAME_MAC=wlx0024d7e31130
413 ID_NET_NAME_PATH=wlp3s0</programlisting>
414 </example>
415
416 <example>
417 <title>PCI IB host adapter with 2 ports</title>
418
419 <programlisting># /sys/devices/pci0000:00/0000:00:03.0/0000:15:00.0/net/ibp21s0f0
420 ID_NET_NAME_PATH=ibp21s0f0
421
422 # /sys/devices/pci0000:00/0000:00:03.0/0000:15:00.1/net/ibp21s0f1
423 ID_NET_NAME_PATH=ibp21s0f1</programlisting>
424 </example>
425
426 <example>
427 <title>USB built-in 3G modem</title>
428
429 <programlisting># /sys/devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.4/2-1.4:1.6/net/wwp0s29u1u4i6
430 ID_NET_NAME_MAC=wwx028037ec0200
431 ID_NET_NAME_PATH=wwp0s29u1u4i6</programlisting>
432 </example>
433
434 <example>
435 <title>USB Android phone</title>
436
437 <programlisting># /sys/devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.2/2-1.2:1.0/net/enp0s29u1u2
438 ID_NET_NAME_MAC=enxd626b3450fb5
439 ID_NET_NAME_PATH=enp0s29u1u2</programlisting>
440 </example>
441
442 <example>
443 <title>s390 grouped CCW interface</title>
444
445 <programlisting># /sys/devices/css0/0.0.0007/0.0.f5f0/group_device/net/encf5f0
446 ID_NET_NAME_MAC=enx026d3c00000a
447 ID_NET_NAME_PATH=encf5f0</programlisting>
448 </example>
449 </refsect1>
450
451 <refsect1>
452 <title>See Also</title>
453 <para>
454 <citerefentry><refentrytitle>udev</refentrytitle><manvolnum>7</manvolnum></citerefentry>,
455 <citerefentry><refentrytitle>udevadm</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
456 <ulink url="https://systemd.io/PREDICTABLE_INTERFACE_NAMES">Predictable Network Interface Names</ulink>,
457 <citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry>
458 </para>
459 </refsect1>
460