]> git.ipfire.org Git - thirdparty/mdadm.git/blob - mdadm.8.in
imsm: Allow to specify controller for --detail-platform.
[thirdparty/mdadm.git] / mdadm.8.in
1 .\" -*- nroff -*-
2 .\" Copyright Neil Brown and others.
3 .\" This program is free software; you can redistribute it and/or modify
4 .\" it under the terms of the GNU General Public License as published by
5 .\" the Free Software Foundation; either version 2 of the License, or
6 .\" (at your option) any later version.
7 .\" See file COPYING in distribution for details.
8 .TH MDADM 8 "" v3.2.5
9 .SH NAME
10 mdadm \- manage MD devices
11 .I aka
12 Linux Software RAID
13
14 .SH SYNOPSIS
15
16 .BI mdadm " [mode] <raiddevice> [options] <component-devices>"
17
18 .SH DESCRIPTION
19 RAID devices are virtual devices created from two or more
20 real block devices. This allows multiple devices (typically disk
21 drives or partitions thereof) to be combined into a single device to
22 hold (for example) a single filesystem.
23 Some RAID levels include redundancy and so can survive some degree of
24 device failure.
25
26 Linux Software RAID devices are implemented through the md (Multiple
27 Devices) device driver.
28
29 Currently, Linux supports
30 .B LINEAR
31 md devices,
32 .B RAID0
33 (striping),
34 .B RAID1
35 (mirroring),
36 .BR RAID4 ,
37 .BR RAID5 ,
38 .BR RAID6 ,
39 .BR RAID10 ,
40 .BR MULTIPATH ,
41 .BR FAULTY ,
42 and
43 .BR CONTAINER .
44
45 .B MULTIPATH
46 is not a Software RAID mechanism, but does involve
47 multiple devices:
48 each device is a path to one common physical storage device.
49 New installations should not use md/multipath as it is not well
50 supported and has no ongoing development. Use the Device Mapper based
51 multipath-tools instead.
52
53 .B FAULTY
54 is also not true RAID, and it only involves one device. It
55 provides a layer over a true device that can be used to inject faults.
56
57 .B CONTAINER
58 is different again. A
59 .B CONTAINER
60 is a collection of devices that are
61 managed as a set. This is similar to the set of devices connected to
62 a hardware RAID controller. The set of devices may contain a number
63 of different RAID arrays each utilising some (or all) of the blocks from a
64 number of the devices in the set. For example, two devices in a 5-device set
65 might form a RAID1 using the whole devices. The remaining three might
66 have a RAID5 over the first half of each device, and a RAID0 over the
67 second half.
68
69 With a
70 .BR CONTAINER ,
71 there is one set of metadata that describes all of
72 the arrays in the container. So when
73 .I mdadm
74 creates a
75 .B CONTAINER
76 device, the device just represents the metadata. Other normal arrays (RAID1
77 etc) can be created inside the container.
78
79 .SH MODES
80 mdadm has several major modes of operation:
81 .TP
82 .B Assemble
83 Assemble the components of a previously created
84 array into an active array. Components can be explicitly given
85 or can be searched for.
86 .I mdadm
87 checks that the components
88 do form a bona fide array, and can, on request, fiddle superblock
89 information so as to assemble a faulty array.
90
91 .TP
92 .B Build
93 Build an array that doesn't have per-device metadata (superblocks). For these
94 sorts of arrays,
95 .I mdadm
96 cannot differentiate between initial creation and subsequent assembly
97 of an array. It also cannot perform any checks that appropriate
98 components have been requested. Because of this, the
99 .B Build
100 mode should only be used together with a complete understanding of
101 what you are doing.
102
103 .TP
104 .B Create
105 Create a new array with per-device metadata (superblocks).
106 Appropriate metadata is written to each device, and then the array
107 comprising those devices is activated. A 'resync' process is started
108 to make sure that the array is consistent (e.g. both sides of a mirror
109 contain the same data) but the content of the device is left otherwise
110 untouched.
111 The array can be used as soon as it has been created. There is no
112 need to wait for the initial resync to finish.
113
114 .TP
115 .B "Follow or Monitor"
116 Monitor one or more md devices and act on any state changes. This is
117 only meaningful for RAID1, 4, 5, 6, 10 or multipath arrays, as
118 only these have interesting state. RAID0 or Linear never have
119 missing, spare, or failed drives, so there is nothing to monitor.
120
121 .TP
122 .B "Grow"
123 Grow (or shrink) an array, or otherwise reshape it in some way.
124 Currently supported growth options including changing the active size
125 of component devices and changing the number of active devices in
126 Linear and RAID levels 0/1/4/5/6,
127 changing the RAID level between 0, 1, 5, and 6, and between 0 and 10,
128 changing the chunk size and layout for RAID 0,4,5,6, as well as adding or
129 removing a write-intent bitmap.
130
131 .TP
132 .B "Incremental Assembly"
133 Add a single device to an appropriate array. If the addition of the
134 device makes the array runnable, the array will be started.
135 This provides a convenient interface to a
136 .I hot-plug
137 system. As each device is detected,
138 .I mdadm
139 has a chance to include it in some array as appropriate.
140 Optionally, when the
141 .I \-\-fail
142 flag is passed in we will remove the device from any active array
143 instead of adding it.
144
145 If a
146 .B CONTAINER
147 is passed to
148 .I mdadm
149 in this mode, then any arrays within that container will be assembled
150 and started.
151
152 .TP
153 .B Manage
154 This is for doing things to specific components of an array such as
155 adding new spares and removing faulty devices.
156
157 .TP
158 .B Misc
159 This is an 'everything else' mode that supports operations on active
160 arrays, operations on component devices such as erasing old superblocks, and
161 information gathering operations.
162 .\"This mode allows operations on independent devices such as examine MD
163 .\"superblocks, erasing old superblocks and stopping active arrays.
164
165 .TP
166 .B Auto-detect
167 This mode does not act on a specific device or array, but rather it
168 requests the Linux Kernel to activate any auto-detected arrays.
169 .SH OPTIONS
170
171 .SH Options for selecting a mode are:
172
173 .TP
174 .BR \-A ", " \-\-assemble
175 Assemble a pre-existing array.
176
177 .TP
178 .BR \-B ", " \-\-build
179 Build a legacy array without superblocks.
180
181 .TP
182 .BR \-C ", " \-\-create
183 Create a new array.
184
185 .TP
186 .BR \-F ", " \-\-follow ", " \-\-monitor
187 Select
188 .B Monitor
189 mode.
190
191 .TP
192 .BR \-G ", " \-\-grow
193 Change the size or shape of an active array.
194
195 .TP
196 .BR \-I ", " \-\-incremental
197 Add/remove a single device to/from an appropriate array, and possibly start the array.
198
199 .TP
200 .B \-\-auto-detect
201 Request that the kernel starts any auto-detected arrays. This can only
202 work if
203 .I md
204 is compiled into the kernel \(em not if it is a module.
205 Arrays can be auto-detected by the kernel if all the components are in
206 primary MS-DOS partitions with partition type
207 .BR FD ,
208 and all use v0.90 metadata.
209 In-kernel autodetect is not recommended for new installations. Using
210 .I mdadm
211 to detect and assemble arrays \(em possibly in an
212 .I initrd
213 \(em is substantially more flexible and should be preferred.
214
215 .P
216 If a device is given before any options, or if the first option is
217 .BR \-\-add ,
218 .BR \-\-fail ,
219 or
220 .BR \-\-remove ,
221 then the MANAGE mode is assumed.
222 Anything other than these will cause the
223 .B Misc
224 mode to be assumed.
225
226 .SH Options that are not mode-specific are:
227
228 .TP
229 .BR \-h ", " \-\-help
230 Display general help message or, after one of the above options, a
231 mode-specific help message.
232
233 .TP
234 .B \-\-help\-options
235 Display more detailed help about command line parsing and some commonly
236 used options.
237
238 .TP
239 .BR \-V ", " \-\-version
240 Print version information for mdadm.
241
242 .TP
243 .BR \-v ", " \-\-verbose
244 Be more verbose about what is happening. This can be used twice to be
245 extra-verbose.
246 The extra verbosity currently only affects
247 .B \-\-detail \-\-scan
248 and
249 .BR "\-\-examine \-\-scan" .
250
251 .TP
252 .BR \-q ", " \-\-quiet
253 Avoid printing purely informative messages. With this,
254 .I mdadm
255 will be silent unless there is something really important to report.
256
257 .TP
258 .BR \-\-offroot
259 Set first character of argv[0] to @ to indicate mdadm was launched
260 from initrd/initramfs and should not be shutdown by systemd as part of
261 the regular shutdown process. This option is normally only used by
262 the system's initscripts. Please see here for more details on how
263 systemd handled argv[0]:
264 .IP
265 .B http://www.freedesktop.org/wiki/Software/systemd/RootStorageDaemons
266 .PP
267
268
269 .TP
270 .BR \-f ", " \-\-force
271 Be more forceful about certain operations. See the various modes for
272 the exact meaning of this option in different contexts.
273
274 .TP
275 .BR \-c ", " \-\-config=
276 Specify the config file. Default is to use
277 .BR /etc/mdadm.conf ,
278 or if that is missing then
279 .BR /etc/mdadm/mdadm.conf .
280 If the config file given is
281 .B "partitions"
282 then nothing will be read, but
283 .I mdadm
284 will act as though the config file contained exactly
285 .B "DEVICE partitions containers"
286 and will read
287 .B /proc/partitions
288 to find a list of devices to scan, and
289 .B /proc/mdstat
290 to find a list of containers to examine.
291 If the word
292 .B "none"
293 is given for the config file, then
294 .I mdadm
295 will act as though the config file were empty.
296
297 .TP
298 .BR \-s ", " \-\-scan
299 Scan config file or
300 .B /proc/mdstat
301 for missing information.
302 In general, this option gives
303 .I mdadm
304 permission to get any missing information (like component devices,
305 array devices, array identities, and alert destination) from the
306 configuration file (see previous option);
307 one exception is MISC mode when using
308 .B \-\-detail
309 or
310 .B \-\-stop,
311 in which case
312 .B \-\-scan
313 says to get a list of array devices from
314 .BR /proc/mdstat .
315
316 .TP
317 .BR \-e ", " \-\-metadata=
318 Declare the style of RAID metadata (superblock) to be used. The
319 default is {DEFAULT_METADATA} for
320 .BR \-\-create ,
321 and to guess for other operations.
322 The default can be overridden by setting the
323 .B metadata
324 value for the
325 .B CREATE
326 keyword in
327 .BR mdadm.conf .
328
329 Options are:
330 .RS
331 .ie '{DEFAULT_METADATA}'0.90'
332 .IP "0, 0.90, default"
333 .el
334 .IP "0, 0.90"
335 ..
336 Use the original 0.90 format superblock. This format limits arrays to
337 28 component devices and limits component devices of levels 1 and
338 greater to 2 terabytes. It is also possible for there to be confusion
339 about whether the superblock applies to a whole device or just the
340 last partition, if that partition starts on a 64K boundary.
341 .ie '{DEFAULT_METADATA}'0.90'
342 .IP "1, 1.0, 1.1, 1.2"
343 .el
344 .IP "1, 1.0, 1.1, 1.2 default"
345 ..
346 Use the new version-1 format superblock. This has fewer restrictions.
347 It can easily be moved between hosts with different endian-ness, and a
348 recovery operation can be checkpointed and restarted. The different
349 sub-versions store the superblock at different locations on the
350 device, either at the end (for 1.0), at the start (for 1.1) or 4K from
351 the start (for 1.2). "1" is equivalent to "1.2" (the commonly
352 preferred 1.x format).
353 'if '{DEFAULT_METADATA}'1.2' "default" is equivalent to "1.2".
354 .IP ddf
355 Use the "Industry Standard" DDF (Disk Data Format) format defined by
356 SNIA.
357 When creating a DDF array a
358 .B CONTAINER
359 will be created, and normal arrays can be created in that container.
360 .IP imsm
361 Use the Intel(R) Matrix Storage Manager metadata format. This creates a
362 .B CONTAINER
363 which is managed in a similar manner to DDF, and is supported by an
364 option-rom on some platforms:
365 .IP
366 .B http://www.intel.com/design/chipsets/matrixstorage_sb.htm
367 .PP
368 .RE
369
370 .TP
371 .B \-\-homehost=
372 This will override any
373 .B HOMEHOST
374 setting in the config file and provides the identity of the host which
375 should be considered the home for any arrays.
376
377 When creating an array, the
378 .B homehost
379 will be recorded in the metadata. For version-1 superblocks, it will
380 be prefixed to the array name. For version-0.90 superblocks, part of
381 the SHA1 hash of the hostname will be stored in the later half of the
382 UUID.
383
384 When reporting information about an array, any array which is tagged
385 for the given homehost will be reported as such.
386
387 When using Auto-Assemble, only arrays tagged for the given homehost
388 will be allowed to use 'local' names (i.e. not ending in '_' followed
389 by a digit string). See below under
390 .BR "Auto Assembly" .
391
392 .TP
393 .B \-\-prefer=
394 When
395 .I mdadm
396 needs to print the name for a device it normally finds the name in
397 .B /dev
398 which refers to the device and is shortest. When a path component is
399 given with
400 .B \-\-prefer
401 .I mdadm
402 will prefer a longer name if it contains that component. For example
403 .B \-\-prefer=by-uuid
404 will prefer a name in a subdirectory of
405 .B /dev
406 called
407 .BR by-uuid .
408
409 This functionality is currently only provided by
410 .B \-\-detail
411 and
412 .BR \-\-monitor .
413
414 .SH For create, build, or grow:
415
416 .TP
417 .BR \-n ", " \-\-raid\-devices=
418 Specify the number of active devices in the array. This, plus the
419 number of spare devices (see below) must equal the number of
420 .I component-devices
421 (including "\fBmissing\fP" devices)
422 that are listed on the command line for
423 .BR \-\-create .
424 Setting a value of 1 is probably
425 a mistake and so requires that
426 .B \-\-force
427 be specified first. A value of 1 will then be allowed for linear,
428 multipath, RAID0 and RAID1. It is never allowed for RAID4, RAID5 or RAID6.
429 .br
430 This number can only be changed using
431 .B \-\-grow
432 for RAID1, RAID4, RAID5 and RAID6 arrays, and only on kernels which provide
433 the necessary support.
434
435 .TP
436 .BR \-x ", " \-\-spare\-devices=
437 Specify the number of spare (eXtra) devices in the initial array.
438 Spares can also be added
439 and removed later. The number of component devices listed
440 on the command line must equal the number of RAID devices plus the
441 number of spare devices.
442
443 .TP
444 .BR \-z ", " \-\-size=
445 Amount (in Kibibytes) of space to use from each drive in RAID levels 1/4/5/6.
446 This must be a multiple of the chunk size, and must leave about 128Kb
447 of space at the end of the drive for the RAID superblock.
448 If this is not specified
449 (as it normally is not) the smallest drive (or partition) sets the
450 size, though if there is a variance among the drives of greater than 1%, a warning is
451 issued.
452
453 A suffix of 'M' or 'G' can be given to indicate Megabytes or
454 Gigabytes respectively.
455
456 Sometimes a replacement drive can be a little smaller than the
457 original drives though this should be minimised by IDEMA standards.
458 Such a replacement drive will be rejected by
459 .IR md .
460 To guard against this it can be useful to set the initial size
461 slightly smaller than the smaller device with the aim that it will
462 still be larger than any replacement.
463
464 This value can be set with
465 .B \-\-grow
466 for RAID level 1/4/5/6 though
467 .B CONTAINER
468 based arrays such as those with IMSM metadata may not be able to
469 support this.
470 If the array was created with a size smaller than the currently
471 active drives, the extra space can be accessed using
472 .BR \-\-grow .
473 The size can be given as
474 .B max
475 which means to choose the largest size that fits on all current drives.
476
477 Before reducing the size of the array (with
478 .BR "\-\-grow \-\-size=" )
479 you should make sure that space isn't needed. If the device holds a
480 filesystem, you would need to resize the filesystem to use less space.
481
482 After reducing the array size you should check that the data stored in
483 the device is still available. If the device holds a filesystem, then
484 an 'fsck' of the filesystem is a minimum requirement. If there are
485 problems the array can be made bigger again with no loss with another
486 .B "\-\-grow \-\-size="
487 command.
488
489 This value cannot be used when creating a
490 .B CONTAINER
491 such as with DDF and IMSM metadata, though it perfectly valid when
492 creating an array inside a container.
493
494 .TP
495 .BR \-Z ", " \-\-array\-size=
496 This is only meaningful with
497 .B \-\-grow
498 and its effect is not persistent: when the array is stopped and
499 restarted the default array size will be restored.
500
501 Setting the array-size causes the array to appear smaller to programs
502 that access the data. This is particularly needed before reshaping an
503 array so that it will be smaller. As the reshape is not reversible,
504 but setting the size with
505 .B \-\-array-size
506 is, it is required that the array size is reduced as appropriate
507 before the number of devices in the array is reduced.
508
509 Before reducing the size of the array you should make sure that space
510 isn't needed. If the device holds a filesystem, you would need to
511 resize the filesystem to use less space.
512
513 After reducing the array size you should check that the data stored in
514 the device is still available. If the device holds a filesystem, then
515 an 'fsck' of the filesystem is a minimum requirement. If there are
516 problems the array can be made bigger again with no loss with another
517 .B "\-\-grow \-\-array\-size="
518 command.
519
520 A suffix of 'M' or 'G' can be given to indicate Megabytes or
521 Gigabytes respectively.
522 A value of
523 .B max
524 restores the apparent size of the array to be whatever the real
525 amount of available space is.
526
527 .TP
528 .BR \-c ", " \-\-chunk=
529 Specify chunk size of kibibytes. The default when creating an
530 array is 512KB. To ensure compatibility with earlier versions, the
531 default when Building and array with no persistent metadata is 64KB.
532 This is only meaningful for RAID0, RAID4, RAID5, RAID6, and RAID10.
533
534 RAID4, RAID5, RAID6, and RAID10 require the chunk size to be a power
535 of 2. In any case it must be a multiple of 4KB.
536
537 A suffix of 'M' or 'G' can be given to indicate Megabytes or
538 Gigabytes respectively.
539
540 .TP
541 .BR \-\-rounding=
542 Specify rounding factor for a Linear array. The size of each
543 component will be rounded down to a multiple of this size.
544 This is a synonym for
545 .B \-\-chunk
546 but highlights the different meaning for Linear as compared to other
547 RAID levels. The default is 64K if a kernel earlier than 2.6.16 is in
548 use, and is 0K (i.e. no rounding) in later kernels.
549
550 .TP
551 .BR \-l ", " \-\-level=
552 Set RAID level. When used with
553 .BR \-\-create ,
554 options are: linear, raid0, 0, stripe, raid1, 1, mirror, raid4, 4,
555 raid5, 5, raid6, 6, raid10, 10, multipath, mp, faulty, container.
556 Obviously some of these are synonymous.
557
558 When a
559 .B CONTAINER
560 metadata type is requested, only the
561 .B container
562 level is permitted, and it does not need to be explicitly given.
563
564 When used with
565 .BR \-\-build ,
566 only linear, stripe, raid0, 0, raid1, multipath, mp, and faulty are valid.
567
568 Can be used with
569 .B \-\-grow
570 to change the RAID level in some cases. See LEVEL CHANGES below.
571
572 .TP
573 .BR \-p ", " \-\-layout=
574 This option configures the fine details of data layout for RAID5, RAID6,
575 and RAID10 arrays, and controls the failure modes for
576 .IR faulty .
577
578 The layout of the RAID5 parity block can be one of
579 .BR left\-asymmetric ,
580 .BR left\-symmetric ,
581 .BR right\-asymmetric ,
582 .BR right\-symmetric ,
583 .BR la ", " ra ", " ls ", " rs .
584 The default is
585 .BR left\-symmetric .
586
587 It is also possible to cause RAID5 to use a RAID4-like layout by
588 choosing
589 .BR parity\-first ,
590 or
591 .BR parity\-last .
592
593 Finally for RAID5 there are DDF\-compatible layouts,
594 .BR ddf\-zero\-restart ,
595 .BR ddf\-N\-restart ,
596 and
597 .BR ddf\-N\-continue .
598
599 These same layouts are available for RAID6. There are also 4 layouts
600 that will provide an intermediate stage for converting between RAID5
601 and RAID6. These provide a layout which is identical to the
602 corresponding RAID5 layout on the first N\-1 devices, and has the 'Q'
603 syndrome (the second 'parity' block used by RAID6) on the last device.
604 These layouts are:
605 .BR left\-symmetric\-6 ,
606 .BR right\-symmetric\-6 ,
607 .BR left\-asymmetric\-6 ,
608 .BR right\-asymmetric\-6 ,
609 and
610 .BR parity\-first\-6 .
611
612 When setting the failure mode for level
613 .I faulty,
614 the options are:
615 .BR write\-transient ", " wt ,
616 .BR read\-transient ", " rt ,
617 .BR write\-persistent ", " wp ,
618 .BR read\-persistent ", " rp ,
619 .BR write\-all ,
620 .BR read\-fixable ", " rf ,
621 .BR clear ", " flush ", " none .
622
623 Each failure mode can be followed by a number, which is used as a period
624 between fault generation. Without a number, the fault is generated
625 once on the first relevant request. With a number, the fault will be
626 generated after that many requests, and will continue to be generated
627 every time the period elapses.
628
629 Multiple failure modes can be current simultaneously by using the
630 .B \-\-grow
631 option to set subsequent failure modes.
632
633 "clear" or "none" will remove any pending or periodic failure modes,
634 and "flush" will clear any persistent faults.
635
636 Finally, the layout options for RAID10 are one of 'n', 'o' or 'f' followed
637 by a small number. The default is 'n2'. The supported options are:
638
639 .I 'n'
640 signals 'near' copies. Multiple copies of one data block are at
641 similar offsets in different devices.
642
643 .I 'o'
644 signals 'offset' copies. Rather than the chunks being duplicated
645 within a stripe, whole stripes are duplicated but are rotated by one
646 device so duplicate blocks are on different devices. Thus subsequent
647 copies of a block are in the next drive, and are one chunk further
648 down.
649
650 .I 'f'
651 signals 'far' copies
652 (multiple copies have very different offsets).
653 See md(4) for more detail about 'near', 'offset', and 'far'.
654
655 The number is the number of copies of each datablock. 2 is normal, 3
656 can be useful. This number can be at most equal to the number of
657 devices in the array. It does not need to divide evenly into that
658 number (e.g. it is perfectly legal to have an 'n2' layout for an array
659 with an odd number of devices).
660
661 When an array is converted between RAID5 and RAID6 an intermediate
662 RAID6 layout is used in which the second parity block (Q) is always on
663 the last device. To convert a RAID5 to RAID6 and leave it in this new
664 layout (which does not require re-striping) use
665 .BR \-\-layout=preserve .
666 This will try to avoid any restriping.
667
668 The converse of this is
669 .B \-\-layout=normalise
670 which will change a non-standard RAID6 layout into a more standard
671 arrangement.
672
673 .TP
674 .BR \-\-parity=
675 same as
676 .B \-\-layout
677 (thus explaining the p of
678 .BR \-p ).
679
680 .TP
681 .BR \-b ", " \-\-bitmap=
682 Specify a file to store a write-intent bitmap in. The file should not
683 exist unless
684 .B \-\-force
685 is also given. The same file should be provided
686 when assembling the array. If the word
687 .B "internal"
688 is given, then the bitmap is stored with the metadata on the array,
689 and so is replicated on all devices. If the word
690 .B "none"
691 is given with
692 .B \-\-grow
693 mode, then any bitmap that is present is removed.
694
695 To help catch typing errors, the filename must contain at least one
696 slash ('/') if it is a real file (not 'internal' or 'none').
697
698 Note: external bitmaps are only known to work on ext2 and ext3.
699 Storing bitmap files on other filesystems may result in serious problems.
700
701 .TP
702 .BR \-\-bitmap\-chunk=
703 Set the chunksize of the bitmap. Each bit corresponds to that many
704 Kilobytes of storage.
705 When using a file based bitmap, the default is to use the smallest
706 size that is at-least 4 and requires no more than 2^21 chunks.
707 When using an
708 .B internal
709 bitmap, the chunksize defaults to 64Meg, or larger if necessary to
710 fit the bitmap into the available space.
711
712 A suffix of 'M' or 'G' can be given to indicate Megabytes or
713 Gigabytes respectively.
714
715 .TP
716 .BR \-W ", " \-\-write\-mostly
717 subsequent devices listed in a
718 .BR \-\-build ,
719 .BR \-\-create ,
720 or
721 .B \-\-add
722 command will be flagged as 'write-mostly'. This is valid for RAID1
723 only and means that the 'md' driver will avoid reading from these
724 devices if at all possible. This can be useful if mirroring over a
725 slow link.
726
727 .TP
728 .BR \-\-write\-behind=
729 Specify that write-behind mode should be enabled (valid for RAID1
730 only). If an argument is specified, it will set the maximum number
731 of outstanding writes allowed. The default value is 256.
732 A write-intent bitmap is required in order to use write-behind
733 mode, and write-behind is only attempted on drives marked as
734 .IR write-mostly .
735
736 .TP
737 .BR \-\-assume\-clean
738 Tell
739 .I mdadm
740 that the array pre-existed and is known to be clean. It can be useful
741 when trying to recover from a major failure as you can be sure that no
742 data will be affected unless you actually write to the array. It can
743 also be used when creating a RAID1 or RAID10 if you want to avoid the
744 initial resync, however this practice \(em while normally safe \(em is not
745 recommended. Use this only if you really know what you are doing.
746 .IP
747 When the devices that will be part of a new array were filled
748 with zeros before creation the operator knows the array is
749 actually clean. If that is the case, such as after running
750 badblocks, this argument can be used to tell mdadm the
751 facts the operator knows.
752 .IP
753 When an array is resized to a larger size with
754 .B "\-\-grow \-\-size="
755 the new space is normally resynced in that same way that the whole
756 array is resynced at creation. From Linux version 3.0,
757 .B \-\-assume\-clean
758 can be used with that command to avoid the automatic resync.
759
760 .TP
761 .BR \-\-backup\-file=
762 This is needed when
763 .B \-\-grow
764 is used to increase the number of raid-devices in a RAID5 or RAID6 if
765 there are no spare devices available, or to shrink, change RAID level
766 or layout. See the GROW MODE section below on RAID\-DEVICES CHANGES.
767 The file must be stored on a separate device, not on the RAID array
768 being reshaped.
769
770 .TP
771 .BR \-\-continue
772 This option is complementary to the
773 .B \-\-freeze-reshape
774 option for assembly. It is needed when
775 .B \-\-grow
776 operation is interrupted and it is not restarted automatically due to
777 .B \-\-freeze-reshape
778 usage during array assembly. This option is used together with
779 .BR \-G
780 , (
781 .BR \-\-grow
782 ) command and device for a pending reshape to be continued.
783 All parameters required for reshape continuation will be read from array metadata.
784 If initial
785 .BR \-\-grow
786 command had required
787 .BR \-\-backup\-file=
788 option to be set, continuation option will require to have exactly the same
789 backup file given as well.
790 .IP
791 Any other parameter passed together with
792 .BR \-\-continue
793 option will be ignored.
794
795 .TP
796 .BR \-N ", " \-\-name=
797 Set a
798 .B name
799 for the array. This is currently only effective when creating an
800 array with a version-1 superblock, or an array in a DDF container.
801 The name is a simple textual string that can be used to identify array
802 components when assembling. If name is needed but not specified, it
803 is taken from the basename of the device that is being created.
804 e.g. when creating
805 .I /dev/md/home
806 the
807 .B name
808 will default to
809 .IR home .
810
811 .TP
812 .BR \-R ", " \-\-run
813 Insist that
814 .I mdadm
815 run the array, even if some of the components
816 appear to be active in another array or filesystem. Normally
817 .I mdadm
818 will ask for confirmation before including such components in an
819 array. This option causes that question to be suppressed.
820
821 .TP
822 .BR \-f ", " \-\-force
823 Insist that
824 .I mdadm
825 accept the geometry and layout specified without question. Normally
826 .I mdadm
827 will not allow creation of an array with only one device, and will try
828 to create a RAID5 array with one missing drive (as this makes the
829 initial resync work faster). With
830 .BR \-\-force ,
831 .I mdadm
832 will not try to be so clever.
833
834 .TP
835 .BR \-o ", " \-\-readonly
836 Start the array
837 .B read only
838 rather than read-write as normal. No writes will be allowed to the
839 array, and no resync, recovery, or reshape will be started.
840
841 .TP
842 .BR \-a ", " "\-\-auto{=yes,md,mdp,part,p}{NN}"
843 Instruct mdadm how to create the device file if needed, possibly allocating
844 an unused minor number. "md" causes a non-partitionable array
845 to be used (though since Linux 2.6.28, these array devices are in fact
846 partitionable). "mdp", "part" or "p" causes a partitionable array (2.6 and
847 later) to be used. "yes" requires the named md device to have
848 a 'standard' format, and the type and minor number will be determined
849 from this. With mdadm 3.0, device creation is normally left up to
850 .I udev
851 so this option is unlikely to be needed.
852 See DEVICE NAMES below.
853
854 The argument can also come immediately after
855 "\-a". e.g. "\-ap".
856
857 If
858 .B \-\-auto
859 is not given on the command line or in the config file, then
860 the default will be
861 .BR \-\-auto=yes .
862
863 If
864 .B \-\-scan
865 is also given, then any
866 .I auto=
867 entries in the config file will override the
868 .B \-\-auto
869 instruction given on the command line.
870
871 For partitionable arrays,
872 .I mdadm
873 will create the device file for the whole array and for the first 4
874 partitions. A different number of partitions can be specified at the
875 end of this option (e.g.
876 .BR \-\-auto=p7 ).
877 If the device name ends with a digit, the partition names add a 'p',
878 and a number, e.g.
879 .IR /dev/md/home1p3 .
880 If there is no trailing digit, then the partition names just have a
881 number added, e.g.
882 .IR /dev/md/scratch3 .
883
884 If the md device name is in a 'standard' format as described in DEVICE
885 NAMES, then it will be created, if necessary, with the appropriate
886 device number based on that name. If the device name is not in one of these
887 formats, then a unused device number will be allocated. The device
888 number will be considered unused if there is no active array for that
889 number, and there is no entry in /dev for that number and with a
890 non-standard name. Names that are not in 'standard' format are only
891 allowed in "/dev/md/".
892
893 This is meaningful with
894 .B \-\-create
895 or
896 .BR \-\-build .
897
898 .ig XX
899 .\".TP
900 .\".BR \-\-symlink = no
901 .\"Normally when
902 .\".B \-\-auto
903 .\"causes
904 .\".I mdadm
905 .\"to create devices in
906 .\".B /dev/md/
907 .\"it will also create symlinks from
908 .\".B /dev/
909 .\"with names starting with
910 .\".B md
911 .\"or
912 .\".BR md_ .
913 .\"Use
914 .\".B \-\-symlink=no
915 .\"to suppress this, or
916 .\".B \-\-symlink=yes
917 .\"to enforce this even if it is suppressing
918 .\".IR mdadm.conf .
919 .\"
920 .XX
921
922 .TP
923 .BR \-a ", " "\-\-add"
924 This option can be used in Grow mode in two cases.
925
926 If the target array is a Linear array, then
927 .B \-\-add
928 can be used to add one or more devices to the array. They
929 are simply catenated on to the end of the array. Once added, the
930 devices cannot be removed.
931
932 If the
933 .B \-\-raid\-disks
934 option is being used to increase the number of devices in an array,
935 then
936 .B \-\-add
937 can be used to add some extra devices to be included in the array.
938 In most cases this is not needed as the extra devices can be added as
939 spares first, and then the number of raid-disks can be changed.
940 However for RAID0, it is not possible to add spares. So to increase
941 the number of devices in a RAID0, it is necessary to set the new
942 number of devices, and to add the new devices, in the same command.
943
944 .SH For assemble:
945
946 .TP
947 .BR \-u ", " \-\-uuid=
948 uuid of array to assemble. Devices which don't have this uuid are
949 excluded
950
951 .TP
952 .BR \-m ", " \-\-super\-minor=
953 Minor number of device that array was created for. Devices which
954 don't have this minor number are excluded. If you create an array as
955 /dev/md1, then all superblocks will contain the minor number 1, even if
956 the array is later assembled as /dev/md2.
957
958 Giving the literal word "dev" for
959 .B \-\-super\-minor
960 will cause
961 .I mdadm
962 to use the minor number of the md device that is being assembled.
963 e.g. when assembling
964 .BR /dev/md0 ,
965 .B \-\-super\-minor=dev
966 will look for super blocks with a minor number of 0.
967
968 .B \-\-super\-minor
969 is only relevant for v0.90 metadata, and should not normally be used.
970 Using
971 .B \-\-uuid
972 is much safer.
973
974 .TP
975 .BR \-N ", " \-\-name=
976 Specify the name of the array to assemble. This must be the name
977 that was specified when creating the array. It must either match
978 the name stored in the superblock exactly, or it must match
979 with the current
980 .I homehost
981 prefixed to the start of the given name.
982
983 .TP
984 .BR \-f ", " \-\-force
985 Assemble the array even if the metadata on some devices appears to be
986 out-of-date. If
987 .I mdadm
988 cannot find enough working devices to start the array, but can find
989 some devices that are recorded as having failed, then it will mark
990 those devices as working so that the array can be started.
991 An array which requires
992 .B \-\-force
993 to be started may contain data corruption. Use it carefully.
994
995 .TP
996 .BR \-R ", " \-\-run
997 Attempt to start the array even if fewer drives were given than were
998 present last time the array was active. Normally if not all the
999 expected drives are found and
1000 .B \-\-scan
1001 is not used, then the array will be assembled but not started.
1002 With
1003 .B \-\-run
1004 an attempt will be made to start it anyway.
1005
1006 .TP
1007 .B \-\-no\-degraded
1008 This is the reverse of
1009 .B \-\-run
1010 in that it inhibits the startup of array unless all expected drives
1011 are present. This is only needed with
1012 .B \-\-scan,
1013 and can be used if the physical connections to devices are
1014 not as reliable as you would like.
1015
1016 .TP
1017 .BR \-a ", " "\-\-auto{=no,yes,md,mdp,part}"
1018 See this option under Create and Build options.
1019
1020 .TP
1021 .BR \-b ", " \-\-bitmap=
1022 Specify the bitmap file that was given when the array was created. If
1023 an array has an
1024 .B internal
1025 bitmap, there is no need to specify this when assembling the array.
1026
1027 .TP
1028 .BR \-\-backup\-file=
1029 If
1030 .B \-\-backup\-file
1031 was used while reshaping an array (e.g. changing number of devices or
1032 chunk size) and the system crashed during the critical section, then the same
1033 .B \-\-backup\-file
1034 must be presented to
1035 .B \-\-assemble
1036 to allow possibly corrupted data to be restored, and the reshape
1037 to be completed.
1038
1039 .TP
1040 .BR \-\-invalid\-backup
1041 If the file needed for the above option is not available for any
1042 reason an empty file can be given together with this option to
1043 indicate that the backup file is invalid. In this case the data that
1044 was being rearranged at the time of the crash could be irrecoverably
1045 lost, but the rest of the array may still be recoverable. This option
1046 should only be used as a last resort if there is no way to recover the
1047 backup file.
1048
1049
1050 .TP
1051 .BR \-U ", " \-\-update=
1052 Update the superblock on each device while assembling the array. The
1053 argument given to this flag can be one of
1054 .BR sparc2.2 ,
1055 .BR summaries ,
1056 .BR uuid ,
1057 .BR name ,
1058 .BR homehost ,
1059 .BR resync ,
1060 .BR byteorder ,
1061 .BR devicesize ,
1062 .BR no\-bitmap ,
1063 .BR bbl ,
1064 .BR no-\bbl ,
1065 or
1066 .BR super\-minor .
1067
1068 The
1069 .B sparc2.2
1070 option will adjust the superblock of an array what was created on a Sparc
1071 machine running a patched 2.2 Linux kernel. This kernel got the
1072 alignment of part of the superblock wrong. You can use the
1073 .B "\-\-examine \-\-sparc2.2"
1074 option to
1075 .I mdadm
1076 to see what effect this would have.
1077
1078 The
1079 .B super\-minor
1080 option will update the
1081 .B "preferred minor"
1082 field on each superblock to match the minor number of the array being
1083 assembled.
1084 This can be useful if
1085 .B \-\-examine
1086 reports a different "Preferred Minor" to
1087 .BR \-\-detail .
1088 In some cases this update will be performed automatically
1089 by the kernel driver. In particular the update happens automatically
1090 at the first write to an array with redundancy (RAID level 1 or
1091 greater) on a 2.6 (or later) kernel.
1092
1093 The
1094 .B uuid
1095 option will change the uuid of the array. If a UUID is given with the
1096 .B \-\-uuid
1097 option that UUID will be used as a new UUID and will
1098 .B NOT
1099 be used to help identify the devices in the array.
1100 If no
1101 .B \-\-uuid
1102 is given, a random UUID is chosen.
1103
1104 The
1105 .B name
1106 option will change the
1107 .I name
1108 of the array as stored in the superblock. This is only supported for
1109 version-1 superblocks.
1110
1111 The
1112 .B homehost
1113 option will change the
1114 .I homehost
1115 as recorded in the superblock. For version-0 superblocks, this is the
1116 same as updating the UUID.
1117 For version-1 superblocks, this involves updating the name.
1118
1119 The
1120 .B resync
1121 option will cause the array to be marked
1122 .I dirty
1123 meaning that any redundancy in the array (e.g. parity for RAID5,
1124 copies for RAID1) may be incorrect. This will cause the RAID system
1125 to perform a "resync" pass to make sure that all redundant information
1126 is correct.
1127
1128 The
1129 .B byteorder
1130 option allows arrays to be moved between machines with different
1131 byte-order.
1132 When assembling such an array for the first time after a move, giving
1133 .B "\-\-update=byteorder"
1134 will cause
1135 .I mdadm
1136 to expect superblocks to have their byteorder reversed, and will
1137 correct that order before assembling the array. This is only valid
1138 with original (Version 0.90) superblocks.
1139
1140 The
1141 .B summaries
1142 option will correct the summaries in the superblock. That is the
1143 counts of total, working, active, failed, and spare devices.
1144
1145 The
1146 .B devicesize
1147 option will rarely be of use. It applies to version 1.1 and 1.2 metadata
1148 only (where the metadata is at the start of the device) and is only
1149 useful when the component device has changed size (typically become
1150 larger). The version 1 metadata records the amount of the device that
1151 can be used to store data, so if a device in a version 1.1 or 1.2
1152 array becomes larger, the metadata will still be visible, but the
1153 extra space will not. In this case it might be useful to assemble the
1154 array with
1155 .BR \-\-update=devicesize .
1156 This will cause
1157 .I mdadm
1158 to determine the maximum usable amount of space on each device and
1159 update the relevant field in the metadata.
1160
1161 The
1162 .B no\-bitmap
1163 option can be used when an array has an internal bitmap which is
1164 corrupt in some way so that assembling the array normally fails. It
1165 will cause any internal bitmap to be ignored.
1166
1167 The
1168 .B bbl
1169 option will reserve space in each device for a bad block list. This
1170 will be 4K in size and positioned near the end of any free space
1171 between the superblock and the data.
1172
1173 The
1174 .B no\-bbl
1175 option will cause any reservation of space for a bad block list to be
1176 removed. If the bad block list contains entries, this will fail, as
1177 removing the list could cause data corruption.
1178
1179 .TP
1180 .BR \-\-freeze\-reshape
1181 Option is intended to be used in start-up scripts during initrd boot phase.
1182 When array under reshape is assembled during initrd phase, this option
1183 stops reshape after reshape critical section is being restored. This happens
1184 before file system pivot operation and avoids loss of file system context.
1185 Losing file system context would cause reshape to be broken.
1186
1187 Reshape can be continued later using the
1188 .B \-\-continue
1189 option for the grow command.
1190
1191 .SH For Manage mode:
1192
1193 .TP
1194 .BR \-t ", " \-\-test
1195 Unless a more serious error occurred,
1196 .I mdadm
1197 will exit with a status of 2 if no changes were made to the array and
1198 0 if at least one change was made.
1199 This can be useful when an indirect specifier such as
1200 .BR missing ,
1201 .B detached
1202 or
1203 .B faulty
1204 is used in requesting an operation on the array.
1205 .B \-\-test
1206 will report failure if these specifiers didn't find any match.
1207
1208 .TP
1209 .BR \-a ", " \-\-add
1210 hot-add listed devices.
1211 If a device appears to have recently been part of the array
1212 (possibly it failed or was removed) the device is re\-added as described
1213 in the next point.
1214 If that fails or the device was never part of the array, the device is
1215 added as a hot-spare.
1216 If the array is degraded, it will immediately start to rebuild data
1217 onto that spare.
1218
1219 Note that this and the following options are only meaningful on array
1220 with redundancy. They don't apply to RAID0 or Linear.
1221
1222 .TP
1223 .BR \-\-re\-add
1224 re\-add a device that was previous removed from an array.
1225 If the metadata on the device reports that it is a member of the
1226 array, and the slot that it used is still vacant, then the device will
1227 be added back to the array in the same position. This will normally
1228 cause the data for that device to be recovered. However based on the
1229 event count on the device, the recovery may only require sections that
1230 are flagged a write-intent bitmap to be recovered or may not require
1231 any recovery at all.
1232
1233 When used on an array that has no metadata (i.e. it was built with
1234 .BR \-\-build)
1235 it will be assumed that bitmap-based recovery is enough to make the
1236 device fully consistent with the array.
1237
1238 When used with v1.x metadata,
1239 .B \-\-re\-add
1240 can be accompanied by
1241 .BR \-\-update=devicesize ,
1242 .BR \-\-update=bbl ", or"
1243 .BR \-\-update=no\-bbl .
1244 See the description of these option when used in Assemble mode for an
1245 explanation of their use.
1246
1247 If the device name given is
1248 .B missing
1249 then mdadm will try to find any device that looks like it should be
1250 part of the array but isn't and will try to re\-add all such devices.
1251
1252 .TP
1253 .BR \-r ", " \-\-remove
1254 remove listed devices. They must not be active. i.e. they should
1255 be failed or spare devices. As well as the name of a device file
1256 (e.g.
1257 .BR /dev/sda1 )
1258 the words
1259 .B failed
1260 and
1261 .B detached
1262 can be given to
1263 .BR \-\-remove .
1264 The first causes all failed device to be removed. The second causes
1265 any device which is no longer connected to the system (i.e an 'open'
1266 returns
1267 .BR ENXIO )
1268 to be removed. This will only succeed for devices that are spares or
1269 have already been marked as failed.
1270
1271 .TP
1272 .BR \-f ", " \-\-fail
1273 mark listed devices as faulty.
1274 As well as the name of a device file, the word
1275 .B detached
1276 can be given. This will cause any device that has been detached from
1277 the system to be marked as failed. It can then be removed.
1278
1279 .TP
1280 .BR \-\-set\-faulty
1281 same as
1282 .BR \-\-fail .
1283
1284 .TP
1285 .BR \-\-write\-mostly
1286 Subsequent devices that are added or re\-added will have the 'write-mostly'
1287 flag set. This is only valid for RAID1 and means that the 'md' driver
1288 will avoid reading from these devices if possible.
1289 .TP
1290 .BR \-\-readwrite
1291 Subsequent devices that are added or re\-added will have the 'write-mostly'
1292 flag cleared.
1293
1294 .P
1295 Each of these options requires that the first device listed is the array
1296 to be acted upon, and the remainder are component devices to be added,
1297 removed, marked as faulty, etc. Several different operations can be
1298 specified for different devices, e.g.
1299 .in +5
1300 mdadm /dev/md0 \-\-add /dev/sda1 \-\-fail /dev/sdb1 \-\-remove /dev/sdb1
1301 .in -5
1302 Each operation applies to all devices listed until the next
1303 operation.
1304
1305 If an array is using a write-intent bitmap, then devices which have
1306 been removed can be re\-added in a way that avoids a full
1307 reconstruction but instead just updates the blocks that have changed
1308 since the device was removed. For arrays with persistent metadata
1309 (superblocks) this is done automatically. For arrays created with
1310 .B \-\-build
1311 mdadm needs to be told that this device we removed recently with
1312 .BR \-\-re\-add .
1313
1314 Devices can only be removed from an array if they are not in active
1315 use, i.e. that must be spares or failed devices. To remove an active
1316 device, it must first be marked as
1317 .B faulty.
1318
1319 .SH For Misc mode:
1320
1321 .TP
1322 .BR \-Q ", " \-\-query
1323 Examine a device to see
1324 (1) if it is an md device and (2) if it is a component of an md
1325 array.
1326 Information about what is discovered is presented.
1327
1328 .TP
1329 .BR \-D ", " \-\-detail
1330 Print details of one or more md devices.
1331
1332 .TP
1333 .BR \-\-detail\-platform
1334 Print details of the platform's RAID capabilities (firmware / hardware
1335 topology) for a given metadata format. If used without argument, mdadm
1336 will scan all controllers looking for their capabilities. Otherwise, mdadm
1337 will only look at the controller specified by the argument in form of an
1338 absolute filepath or a link, e.g.
1339 .IR /sys/devices/pci0000:00/0000:00:1f.2 .
1340
1341 .TP
1342 .BR \-Y ", " \-\-export
1343 When used with
1344 .B \-\-detail , \-\-detail-platform
1345 or
1346 .BR \-\-examine ,
1347 output will be formatted as
1348 .B key=value
1349 pairs for easy import into the environment.
1350
1351 .TP
1352 .BR \-E ", " \-\-examine
1353 Print contents of the metadata stored on the named device(s).
1354 Note the contrast between
1355 .B \-\-examine
1356 and
1357 .BR \-\-detail .
1358 .B \-\-examine
1359 applies to devices which are components of an array, while
1360 .B \-\-detail
1361 applies to a whole array which is currently active.
1362 .TP
1363 .B \-\-sparc2.2
1364 If an array was created on a SPARC machine with a 2.2 Linux kernel
1365 patched with RAID support, the superblock will have been created
1366 incorrectly, or at least incompatibly with 2.4 and later kernels.
1367 Using the
1368 .B \-\-sparc2.2
1369 flag with
1370 .B \-\-examine
1371 will fix the superblock before displaying it. If this appears to do
1372 the right thing, then the array can be successfully assembled using
1373 .BR "\-\-assemble \-\-update=sparc2.2" .
1374
1375 .TP
1376 .BR \-X ", " \-\-examine\-bitmap
1377 Report information about a bitmap file.
1378 The argument is either an external bitmap file or an array component
1379 in case of an internal bitmap. Note that running this on an array
1380 device (e.g.
1381 .BR /dev/md0 )
1382 does not report the bitmap for that array.
1383
1384 .TP
1385 .BR \-R ", " \-\-run
1386 start a partially assembled array. If
1387 .B \-\-assemble
1388 did not find enough devices to fully start the array, it might leaving
1389 it partially assembled. If you wish, you can then use
1390 .B \-\-run
1391 to start the array in degraded mode.
1392
1393 .TP
1394 .BR \-S ", " \-\-stop
1395 deactivate array, releasing all resources.
1396
1397 .TP
1398 .BR \-o ", " \-\-readonly
1399 mark array as readonly.
1400
1401 .TP
1402 .BR \-w ", " \-\-readwrite
1403 mark array as readwrite.
1404
1405 .TP
1406 .B \-\-zero\-superblock
1407 If the device contains a valid md superblock, the block is
1408 overwritten with zeros. With
1409 .B \-\-force
1410 the block where the superblock would be is overwritten even if it
1411 doesn't appear to be valid.
1412
1413 .TP
1414 .B \-\-kill\-subarray=
1415 If the device is a container and the argument to \-\-kill\-subarray
1416 specifies an inactive subarray in the container, then the subarray is
1417 deleted. Deleting all subarrays will leave an 'empty-container' or
1418 spare superblock on the drives. See \-\-zero\-superblock for completely
1419 removing a superblock. Note that some formats depend on the subarray
1420 index for generating a UUID, this command will fail if it would change
1421 the UUID of an active subarray.
1422
1423 .TP
1424 .B \-\-update\-subarray=
1425 If the device is a container and the argument to \-\-update\-subarray
1426 specifies a subarray in the container, then attempt to update the given
1427 superblock field in the subarray. See below in
1428 .B MISC MODE
1429 for details.
1430
1431 .TP
1432 .BR \-t ", " \-\-test
1433 When used with
1434 .BR \-\-detail ,
1435 the exit status of
1436 .I mdadm
1437 is set to reflect the status of the device. See below in
1438 .B MISC MODE
1439 for details.
1440
1441 .TP
1442 .BR \-W ", " \-\-wait
1443 For each md device given, wait for any resync, recovery, or reshape
1444 activity to finish before returning.
1445 .I mdadm
1446 will return with success if it actually waited for every device
1447 listed, otherwise it will return failure.
1448
1449 .TP
1450 .BR \-\-wait\-clean
1451 For each md device given, or each device in /proc/mdstat if
1452 .B \-\-scan
1453 is given, arrange for the array to be marked clean as soon as possible.
1454 .I mdadm
1455 will return with success if the array uses external metadata and we
1456 successfully waited. For native arrays this returns immediately as the
1457 kernel handles dirty-clean transitions at shutdown. No action is taken
1458 if safe-mode handling is disabled.
1459
1460 .SH For Incremental Assembly mode:
1461 .TP
1462 .BR \-\-rebuild\-map ", " \-r
1463 Rebuild the map file
1464 .RB ( {MAP_PATH} )
1465 that
1466 .I mdadm
1467 uses to help track which arrays are currently being assembled.
1468
1469 .TP
1470 .BR \-\-run ", " \-R
1471 Run any array assembled as soon as a minimal number of devices are
1472 available, rather than waiting until all expected devices are present.
1473
1474 .TP
1475 .BR \-\-scan ", " \-s
1476 Only meaningful with
1477 .B \-R
1478 this will scan the
1479 .B map
1480 file for arrays that are being incrementally assembled and will try to
1481 start any that are not already started. If any such array is listed
1482 in
1483 .B mdadm.conf
1484 as requiring an external bitmap, that bitmap will be attached first.
1485
1486 .TP
1487 .BR \-\-fail ", " \-f
1488 This allows the hot-plug system to remove devices that have fully disappeared
1489 from the kernel. It will first fail and then remove the device from any
1490 array it belongs to.
1491 The device name given should be a kernel device name such as "sda",
1492 not a name in
1493 .IR /dev .
1494
1495 .TP
1496 .BR \-\-path=
1497 Only used with \-\-fail. The 'path' given will be recorded so that if
1498 a new device appears at the same location it can be automatically
1499 added to the same array. This allows the failed device to be
1500 automatically replaced by a new device without metadata if it appears
1501 at specified path. This option is normally only set by a
1502 .I udev
1503 script.
1504
1505 .SH For Monitor mode:
1506 .TP
1507 .BR \-m ", " \-\-mail
1508 Give a mail address to send alerts to.
1509
1510 .TP
1511 .BR \-p ", " \-\-program ", " \-\-alert
1512 Give a program to be run whenever an event is detected.
1513
1514 .TP
1515 .BR \-y ", " \-\-syslog
1516 Cause all events to be reported through 'syslog'. The messages have
1517 facility of 'daemon' and varying priorities.
1518
1519 .TP
1520 .BR \-d ", " \-\-delay
1521 Give a delay in seconds.
1522 .I mdadm
1523 polls the md arrays and then waits this many seconds before polling
1524 again. The default is 60 seconds. Since 2.6.16, there is no need to
1525 reduce this as the kernel alerts
1526 .I mdadm
1527 immediately when there is any change.
1528
1529 .TP
1530 .BR \-r ", " \-\-increment
1531 Give a percentage increment.
1532 .I mdadm
1533 will generate RebuildNN events with the given percentage increment.
1534
1535 .TP
1536 .BR \-f ", " \-\-daemonise
1537 Tell
1538 .I mdadm
1539 to run as a background daemon if it decides to monitor anything. This
1540 causes it to fork and run in the child, and to disconnect from the
1541 terminal. The process id of the child is written to stdout.
1542 This is useful with
1543 .B \-\-scan
1544 which will only continue monitoring if a mail address or alert program
1545 is found in the config file.
1546
1547 .TP
1548 .BR \-i ", " \-\-pid\-file
1549 When
1550 .I mdadm
1551 is running in daemon mode, write the pid of the daemon process to
1552 the specified file, instead of printing it on standard output.
1553
1554 .TP
1555 .BR \-1 ", " \-\-oneshot
1556 Check arrays only once. This will generate
1557 .B NewArray
1558 events and more significantly
1559 .B DegradedArray
1560 and
1561 .B SparesMissing
1562 events. Running
1563 .in +5
1564 .B " mdadm \-\-monitor \-\-scan \-1"
1565 .in -5
1566 from a cron script will ensure regular notification of any degraded arrays.
1567
1568 .TP
1569 .BR \-t ", " \-\-test
1570 Generate a
1571 .B TestMessage
1572 alert for every array found at startup. This alert gets mailed and
1573 passed to the alert program. This can be used for testing that alert
1574 message do get through successfully.
1575
1576 .TP
1577 .BR \-\-no\-sharing
1578 This inhibits the functionality for moving spares between arrays.
1579 Only one monitoring process started with
1580 .B \-\-scan
1581 but without this flag is allowed, otherwise the two could interfere
1582 with each other.
1583
1584 .SH ASSEMBLE MODE
1585
1586 .HP 12
1587 Usage:
1588 .B mdadm \-\-assemble
1589 .I md-device options-and-component-devices...
1590 .HP 12
1591 Usage:
1592 .B mdadm \-\-assemble \-\-scan
1593 .I md-devices-and-options...
1594 .HP 12
1595 Usage:
1596 .B mdadm \-\-assemble \-\-scan
1597 .I options...
1598
1599 .PP
1600 This usage assembles one or more RAID arrays from pre-existing components.
1601 For each array, mdadm needs to know the md device, the identity of the
1602 array, and a number of component-devices. These can be found in a number of ways.
1603
1604 In the first usage example (without the
1605 .BR \-\-scan )
1606 the first device given is the md device.
1607 In the second usage example, all devices listed are treated as md
1608 devices and assembly is attempted.
1609 In the third (where no devices are listed) all md devices that are
1610 listed in the configuration file are assembled. If no arrays are
1611 described by the configuration file, then any arrays that
1612 can be found on unused devices will be assembled.
1613
1614 If precisely one device is listed, but
1615 .B \-\-scan
1616 is not given, then
1617 .I mdadm
1618 acts as though
1619 .B \-\-scan
1620 was given and identity information is extracted from the configuration file.
1621
1622 The identity can be given with the
1623 .B \-\-uuid
1624 option, the
1625 .B \-\-name
1626 option, or the
1627 .B \-\-super\-minor
1628 option, will be taken from the md-device record in the config file, or
1629 will be taken from the super block of the first component-device
1630 listed on the command line.
1631
1632 Devices can be given on the
1633 .B \-\-assemble
1634 command line or in the config file. Only devices which have an md
1635 superblock which contains the right identity will be considered for
1636 any array.
1637
1638 The config file is only used if explicitly named with
1639 .B \-\-config
1640 or requested with (a possibly implicit)
1641 .BR \-\-scan .
1642 In the later case,
1643 .B /etc/mdadm.conf
1644 or
1645 .B /etc/mdadm/mdadm.conf
1646 is used.
1647
1648 If
1649 .B \-\-scan
1650 is not given, then the config file will only be used to find the
1651 identity of md arrays.
1652
1653 Normally the array will be started after it is assembled. However if
1654 .B \-\-scan
1655 is not given and not all expected drives were listed, then the array
1656 is not started (to guard against usage errors). To insist that the
1657 array be started in this case (as may work for RAID1, 4, 5, 6, or 10),
1658 give the
1659 .B \-\-run
1660 flag.
1661
1662 If
1663 .I udev
1664 is active,
1665 .I mdadm
1666 does not create any entries in
1667 .B /dev
1668 but leaves that to
1669 .IR udev .
1670 It does record information in
1671 .B {MAP_PATH}
1672 which will allow
1673 .I udev
1674 to choose the correct name.
1675
1676 If
1677 .I mdadm
1678 detects that udev is not configured, it will create the devices in
1679 .B /dev
1680 itself.
1681
1682 In Linux kernels prior to version 2.6.28 there were two distinctly
1683 different types of md devices that could be created: one that could be
1684 partitioned using standard partitioning tools and one that could not.
1685 Since 2.6.28 that distinction is no longer relevant as both type of
1686 devices can be partitioned.
1687 .I mdadm
1688 will normally create the type that originally could not be partitioned
1689 as it has a well defined major number (9).
1690
1691 Prior to 2.6.28, it is important that mdadm chooses the correct type
1692 of array device to use. This can be controlled with the
1693 .B \-\-auto
1694 option. In particular, a value of "mdp" or "part" or "p" tells mdadm
1695 to use a partitionable device rather than the default.
1696
1697 In the no-udev case, the value given to
1698 .B \-\-auto
1699 can be suffixed by a number. This tells
1700 .I mdadm
1701 to create that number of partition devices rather than the default of 4.
1702
1703 The value given to
1704 .B \-\-auto
1705 can also be given in the configuration file as a word starting
1706 .B auto=
1707 on the ARRAY line for the relevant array.
1708
1709 .SS Auto Assembly
1710 When
1711 .B \-\-assemble
1712 is used with
1713 .B \-\-scan
1714 and no devices are listed,
1715 .I mdadm
1716 will first attempt to assemble all the arrays listed in the config
1717 file.
1718
1719 If no arrays are listed in the config (other than those marked
1720 .BR <ignore> )
1721 it will look through the available devices for possible arrays and
1722 will try to assemble anything that it finds. Arrays which are tagged
1723 as belonging to the given homehost will be assembled and started
1724 normally. Arrays which do not obviously belong to this host are given
1725 names that are expected not to conflict with anything local, and are
1726 started "read-auto" so that nothing is written to any device until the
1727 array is written to. i.e. automatic resync etc is delayed.
1728
1729 If
1730 .I mdadm
1731 finds a consistent set of devices that look like they should comprise
1732 an array, and if the superblock is tagged as belonging to the given
1733 home host, it will automatically choose a device name and try to
1734 assemble the array. If the array uses version-0.90 metadata, then the
1735 .B minor
1736 number as recorded in the superblock is used to create a name in
1737 .B /dev/md/
1738 so for example
1739 .BR /dev/md/3 .
1740 If the array uses version-1 metadata, then the
1741 .B name
1742 from the superblock is used to similarly create a name in
1743 .B /dev/md/
1744 (the name will have any 'host' prefix stripped first).
1745
1746 This behaviour can be modified by the
1747 .I AUTO
1748 line in the
1749 .I mdadm.conf
1750 configuration file. This line can indicate that specific metadata
1751 type should, or should not, be automatically assembled. If an array
1752 is found which is not listed in
1753 .I mdadm.conf
1754 and has a metadata format that is denied by the
1755 .I AUTO
1756 line, then it will not be assembled.
1757 The
1758 .I AUTO
1759 line can also request that all arrays identified as being for this
1760 homehost should be assembled regardless of their metadata type.
1761 See
1762 .IR mdadm.conf (5)
1763 for further details.
1764
1765 Note: Auto assembly cannot be used for assembling and activating some
1766 arrays which are undergoing reshape. In particular as the
1767 .B backup\-file
1768 cannot be given, any reshape which requires a backup-file to continue
1769 cannot be started by auto assembly. An array which is growing to more
1770 devices and has passed the critical section can be assembled using
1771 auto-assembly.
1772
1773 .SH BUILD MODE
1774
1775 .HP 12
1776 Usage:
1777 .B mdadm \-\-build
1778 .I md-device
1779 .BI \-\-chunk= X
1780 .BI \-\-level= Y
1781 .BI \-\-raid\-devices= Z
1782 .I devices
1783
1784 .PP
1785 This usage is similar to
1786 .BR \-\-create .
1787 The difference is that it creates an array without a superblock. With
1788 these arrays there is no difference between initially creating the array and
1789 subsequently assembling the array, except that hopefully there is useful
1790 data there in the second case.
1791
1792 The level may raid0, linear, raid1, raid10, multipath, or faulty, or
1793 one of their synonyms. All devices must be listed and the array will
1794 be started once complete. It will often be appropriate to use
1795 .B \-\-assume\-clean
1796 with levels raid1 or raid10.
1797
1798 .SH CREATE MODE
1799
1800 .HP 12
1801 Usage:
1802 .B mdadm \-\-create
1803 .I md-device
1804 .BI \-\-chunk= X
1805 .BI \-\-level= Y
1806 .br
1807 .BI \-\-raid\-devices= Z
1808 .I devices
1809
1810 .PP
1811 This usage will initialise a new md array, associate some devices with
1812 it, and activate the array.
1813
1814 The named device will normally not exist when
1815 .I "mdadm \-\-create"
1816 is run, but will be created by
1817 .I udev
1818 once the array becomes active.
1819
1820 As devices are added, they are checked to see if they contain RAID
1821 superblocks or filesystems. They are also checked to see if the variance in
1822 device size exceeds 1%.
1823
1824 If any discrepancy is found, the array will not automatically be run, though
1825 the presence of a
1826 .B \-\-run
1827 can override this caution.
1828
1829 To create a "degraded" array in which some devices are missing, simply
1830 give the word "\fBmissing\fP"
1831 in place of a device name. This will cause
1832 .I mdadm
1833 to leave the corresponding slot in the array empty.
1834 For a RAID4 or RAID5 array at most one slot can be
1835 "\fBmissing\fP"; for a RAID6 array at most two slots.
1836 For a RAID1 array, only one real device needs to be given. All of the
1837 others can be
1838 "\fBmissing\fP".
1839
1840 When creating a RAID5 array,
1841 .I mdadm
1842 will automatically create a degraded array with an extra spare drive.
1843 This is because building the spare into a degraded array is in general
1844 faster than resyncing the parity on a non-degraded, but not clean,
1845 array. This feature can be overridden with the
1846 .B \-\-force
1847 option.
1848
1849 When creating an array with version-1 metadata a name for the array is
1850 required.
1851 If this is not given with the
1852 .B \-\-name
1853 option,
1854 .I mdadm
1855 will choose a name based on the last component of the name of the
1856 device being created. So if
1857 .B /dev/md3
1858 is being created, then the name
1859 .B 3
1860 will be chosen.
1861 If
1862 .B /dev/md/home
1863 is being created, then the name
1864 .B home
1865 will be used.
1866
1867 When creating a partition based array, using
1868 .I mdadm
1869 with version-1.x metadata, the partition type should be set to
1870 .B 0xDA
1871 (non fs-data). This type selection allows for greater precision since
1872 using any other [RAID auto-detect (0xFD) or a GNU/Linux partition (0x83)],
1873 might create problems in the event of array recovery through a live cdrom.
1874
1875 A new array will normally get a randomly assigned 128bit UUID which is
1876 very likely to be unique. If you have a specific need, you can choose
1877 a UUID for the array by giving the
1878 .B \-\-uuid=
1879 option. Be warned that creating two arrays with the same UUID is a
1880 recipe for disaster. Also, using
1881 .B \-\-uuid=
1882 when creating a v0.90 array will silently override any
1883 .B \-\-homehost=
1884 setting.
1885 .\"If the
1886 .\".B \-\-size
1887 .\"option is given, it is not necessary to list any component-devices in this command.
1888 .\"They can be added later, before a
1889 .\".B \-\-run.
1890 .\"If no
1891 .\".B \-\-size
1892 .\"is given, the apparent size of the smallest drive given is used.
1893
1894 If the metadata type supports it (currently only 1.x metadata), space
1895 will be allocated to store a bad block list. This allows a modest
1896 number of bad blocks to be recorded, allowing the drive to remain in
1897 service while only partially functional.
1898
1899 When creating an array within a
1900 .B CONTAINER
1901 .I mdadm
1902 can be given either the list of devices to use, or simply the name of
1903 the container. The former case gives control over which devices in
1904 the container will be used for the array. The latter case allows
1905 .I mdadm
1906 to automatically choose which devices to use based on how much spare
1907 space is available.
1908
1909 The General Management options that are valid with
1910 .B \-\-create
1911 are:
1912 .TP
1913 .B \-\-run
1914 insist on running the array even if some devices look like they might
1915 be in use.
1916
1917 .TP
1918 .B \-\-readonly
1919 start the array readonly \(em not supported yet.
1920
1921 .SH MANAGE MODE
1922 .HP 12
1923 Usage:
1924 .B mdadm
1925 .I device
1926 .I options... devices...
1927 .PP
1928
1929 This usage will allow individual devices in an array to be failed,
1930 removed or added. It is possible to perform multiple operations with
1931 on command. For example:
1932 .br
1933 .B " mdadm /dev/md0 \-f /dev/hda1 \-r /dev/hda1 \-a /dev/hda1"
1934 .br
1935 will firstly mark
1936 .B /dev/hda1
1937 as faulty in
1938 .B /dev/md0
1939 and will then remove it from the array and finally add it back
1940 in as a spare. However only one md array can be affected by a single
1941 command.
1942
1943 When a device is added to an active array, mdadm checks to see if it
1944 has metadata on it which suggests that it was recently a member of the
1945 array. If it does, it tries to "re\-add" the device. If there have
1946 been no changes since the device was removed, or if the array has a
1947 write-intent bitmap which has recorded whatever changes there were,
1948 then the device will immediately become a full member of the array and
1949 those differences recorded in the bitmap will be resolved.
1950
1951 .SH MISC MODE
1952 .HP 12
1953 Usage:
1954 .B mdadm
1955 .I options ...
1956 .I devices ...
1957 .PP
1958
1959 MISC mode includes a number of distinct operations that
1960 operate on distinct devices. The operations are:
1961 .TP
1962 .B \-\-query
1963 The device is examined to see if it is
1964 (1) an active md array, or
1965 (2) a component of an md array.
1966 The information discovered is reported.
1967
1968 .TP
1969 .B \-\-detail
1970 The device should be an active md device.
1971 .B mdadm
1972 will display a detailed description of the array.
1973 .B \-\-brief
1974 or
1975 .B \-\-scan
1976 will cause the output to be less detailed and the format to be
1977 suitable for inclusion in
1978 .BR mdadm.conf .
1979 The exit status of
1980 .I mdadm
1981 will normally be 0 unless
1982 .I mdadm
1983 failed to get useful information about the device(s); however, if the
1984 .B \-\-test
1985 option is given, then the exit status will be:
1986 .RS
1987 .TP
1988 0
1989 The array is functioning normally.
1990 .TP
1991 1
1992 The array has at least one failed device.
1993 .TP
1994 2
1995 The array has multiple failed devices such that it is unusable.
1996 .TP
1997 4
1998 There was an error while trying to get information about the device.
1999 .RE
2000
2001 .TP
2002 .B \-\-detail\-platform
2003 Print detail of the platform's RAID capabilities (firmware / hardware
2004 topology). If the metadata is specified with
2005 .B \-e
2006 or
2007 .B \-\-metadata=
2008 then the return status will be:
2009 .RS
2010 .TP
2011 0
2012 metadata successfully enumerated its platform components on this system
2013 .TP
2014 1
2015 metadata is platform independent
2016 .TP
2017 2
2018 metadata failed to find its platform components on this system
2019 .RE
2020
2021 .TP
2022 .B \-\-update\-subarray=
2023 If the device is a container and the argument to \-\-update\-subarray
2024 specifies a subarray in the container, then attempt to update the given
2025 superblock field in the subarray. Similar to updating an array in
2026 "assemble" mode, the field to update is selected by
2027 .B \-U
2028 or
2029 .B \-\-update=
2030 option. Currently only
2031 .B name
2032 is supported.
2033
2034 The
2035 .B name
2036 option updates the subarray name in the metadata, it may not affect the
2037 device node name or the device node symlink until the subarray is
2038 re\-assembled. If updating
2039 .B name
2040 would change the UUID of an active subarray this operation is blocked,
2041 and the command will end in an error.
2042
2043 .TP
2044 .B \-\-examine
2045 The device should be a component of an md array.
2046 .I mdadm
2047 will read the md superblock of the device and display the contents.
2048 If
2049 .B \-\-brief
2050 or
2051 .B \-\-scan
2052 is given, then multiple devices that are components of the one array
2053 are grouped together and reported in a single entry suitable
2054 for inclusion in
2055 .BR mdadm.conf .
2056
2057 Having
2058 .B \-\-scan
2059 without listing any devices will cause all devices listed in the
2060 config file to be examined.
2061
2062 .TP
2063 .B \-\-stop
2064 The devices should be active md arrays which will be deactivated, as
2065 long as they are not currently in use.
2066
2067 .TP
2068 .B \-\-run
2069 This will fully activate a partially assembled md array.
2070
2071 .TP
2072 .B \-\-readonly
2073 This will mark an active array as read-only, providing that it is
2074 not currently being used.
2075
2076 .TP
2077 .B \-\-readwrite
2078 This will change a
2079 .B readonly
2080 array back to being read/write.
2081
2082 .TP
2083 .B \-\-scan
2084 For all operations except
2085 .BR \-\-examine ,
2086 .B \-\-scan
2087 will cause the operation to be applied to all arrays listed in
2088 .BR /proc/mdstat .
2089 For
2090 .BR \-\-examine,
2091 .B \-\-scan
2092 causes all devices listed in the config file to be examined.
2093
2094 .TP
2095 .BR \-b ", " \-\-brief
2096 Be less verbose. This is used with
2097 .B \-\-detail
2098 and
2099 .BR \-\-examine .
2100 Using
2101 .B \-\-brief
2102 with
2103 .B \-\-verbose
2104 gives an intermediate level of verbosity.
2105
2106 .SH MONITOR MODE
2107
2108 .HP 12
2109 Usage:
2110 .B mdadm \-\-monitor
2111 .I options... devices...
2112
2113 .PP
2114 This usage causes
2115 .I mdadm
2116 to periodically poll a number of md arrays and to report on any events
2117 noticed.
2118 .I mdadm
2119 will never exit once it decides that there are arrays to be checked,
2120 so it should normally be run in the background.
2121
2122 As well as reporting events,
2123 .I mdadm
2124 may move a spare drive from one array to another if they are in the
2125 same
2126 .B spare-group
2127 or
2128 .B domain
2129 and if the destination array has a failed drive but no spares.
2130
2131 If any devices are listed on the command line,
2132 .I mdadm
2133 will only monitor those devices. Otherwise all arrays listed in the
2134 configuration file will be monitored. Further, if
2135 .B \-\-scan
2136 is given, then any other md devices that appear in
2137 .B /proc/mdstat
2138 will also be monitored.
2139
2140 The result of monitoring the arrays is the generation of events.
2141 These events are passed to a separate program (if specified) and may
2142 be mailed to a given E-mail address.
2143
2144 When passing events to a program, the program is run once for each event,
2145 and is given 2 or 3 command-line arguments: the first is the
2146 name of the event (see below), the second is the name of the
2147 md device which is affected, and the third is the name of a related
2148 device if relevant (such as a component device that has failed).
2149
2150 If
2151 .B \-\-scan
2152 is given, then a program or an E-mail address must be specified on the
2153 command line or in the config file. If neither are available, then
2154 .I mdadm
2155 will not monitor anything.
2156 Without
2157 .B \-\-scan,
2158 .I mdadm
2159 will continue monitoring as long as something was found to monitor. If
2160 no program or email is given, then each event is reported to
2161 .BR stdout .
2162
2163 The different events are:
2164
2165 .RS 4
2166 .TP
2167 .B DeviceDisappeared
2168 An md array which previously was configured appears to no longer be
2169 configured. (syslog priority: Critical)
2170
2171 If
2172 .I mdadm
2173 was told to monitor an array which is RAID0 or Linear, then it will
2174 report
2175 .B DeviceDisappeared
2176 with the extra information
2177 .BR Wrong-Level .
2178 This is because RAID0 and Linear do not support the device-failed,
2179 hot-spare and resync operations which are monitored.
2180
2181 .TP
2182 .B RebuildStarted
2183 An md array started reconstruction. (syslog priority: Warning)
2184
2185 .TP
2186 .BI Rebuild NN
2187 Where
2188 .I NN
2189 is a two-digit number (ie. 05, 48). This indicates that rebuild
2190 has passed that many percent of the total. The events are generated
2191 with fixed increment since 0. Increment size may be specified with
2192 a commandline option (default is 20). (syslog priority: Warning)
2193
2194 .TP
2195 .B RebuildFinished
2196 An md array that was rebuilding, isn't any more, either because it
2197 finished normally or was aborted. (syslog priority: Warning)
2198
2199 .TP
2200 .B Fail
2201 An active component device of an array has been marked as
2202 faulty. (syslog priority: Critical)
2203
2204 .TP
2205 .B FailSpare
2206 A spare component device which was being rebuilt to replace a faulty
2207 device has failed. (syslog priority: Critical)
2208
2209 .TP
2210 .B SpareActive
2211 A spare component device which was being rebuilt to replace a faulty
2212 device has been successfully rebuilt and has been made active.
2213 (syslog priority: Info)
2214
2215 .TP
2216 .B NewArray
2217 A new md array has been detected in the
2218 .B /proc/mdstat
2219 file. (syslog priority: Info)
2220
2221 .TP
2222 .B DegradedArray
2223 A newly noticed array appears to be degraded. This message is not
2224 generated when
2225 .I mdadm
2226 notices a drive failure which causes degradation, but only when
2227 .I mdadm
2228 notices that an array is degraded when it first sees the array.
2229 (syslog priority: Critical)
2230
2231 .TP
2232 .B MoveSpare
2233 A spare drive has been moved from one array in a
2234 .B spare-group
2235 or
2236 .B domain
2237 to another to allow a failed drive to be replaced.
2238 (syslog priority: Info)
2239
2240 .TP
2241 .B SparesMissing
2242 If
2243 .I mdadm
2244 has been told, via the config file, that an array should have a certain
2245 number of spare devices, and
2246 .I mdadm
2247 detects that it has fewer than this number when it first sees the
2248 array, it will report a
2249 .B SparesMissing
2250 message.
2251 (syslog priority: Warning)
2252
2253 .TP
2254 .B TestMessage
2255 An array was found at startup, and the
2256 .B \-\-test
2257 flag was given.
2258 (syslog priority: Info)
2259 .RE
2260
2261 Only
2262 .B Fail,
2263 .B FailSpare,
2264 .B DegradedArray,
2265 .B SparesMissing
2266 and
2267 .B TestMessage
2268 cause Email to be sent. All events cause the program to be run.
2269 The program is run with two or three arguments: the event
2270 name, the array device and possibly a second device.
2271
2272 Each event has an associated array device (e.g.
2273 .BR /dev/md1 )
2274 and possibly a second device. For
2275 .BR Fail ,
2276 .BR FailSpare ,
2277 and
2278 .B SpareActive
2279 the second device is the relevant component device.
2280 For
2281 .B MoveSpare
2282 the second device is the array that the spare was moved from.
2283
2284 For
2285 .I mdadm
2286 to move spares from one array to another, the different arrays need to
2287 be labeled with the same
2288 .B spare-group
2289 or the spares must be allowed to migrate through matching POLICY domains
2290 in the configuration file. The
2291 .B spare-group
2292 name can be any string; it is only necessary that different spare
2293 groups use different names.
2294
2295 When
2296 .I mdadm
2297 detects that an array in a spare group has fewer active
2298 devices than necessary for the complete array, and has no spare
2299 devices, it will look for another array in the same spare group that
2300 has a full complement of working drive and a spare. It will then
2301 attempt to remove the spare from the second drive and add it to the
2302 first.
2303 If the removal succeeds but the adding fails, then it is added back to
2304 the original array.
2305
2306 If the spare group for a degraded array is not defined,
2307 .I mdadm
2308 will look at the rules of spare migration specified by POLICY lines in
2309 .B mdadm.conf
2310 and then follow similar steps as above if a matching spare is found.
2311
2312 .SH GROW MODE
2313 The GROW mode is used for changing the size or shape of an active
2314 array.
2315 For this to work, the kernel must support the necessary change.
2316 Various types of growth are being added during 2.6 development.
2317
2318 Currently the supported changes include
2319 .IP \(bu 4
2320 change the "size" attribute for RAID1, RAID4, RAID5 and RAID6.
2321 .IP \(bu 4
2322 increase or decrease the "raid\-devices" attribute of RAID0, RAID1, RAID4,
2323 RAID5, and RAID6.
2324 .IP \(bu 4
2325 change the chunk-size and layout of RAID0, RAID4, RAID5 and RAID6.
2326 .IP \(bu 4
2327 convert between RAID1 and RAID5, between RAID5 and RAID6, between
2328 RAID0, RAID4, and RAID5, and between RAID0 and RAID10 (in the near-2 mode).
2329 .IP \(bu 4
2330 add a write-intent bitmap to any array which supports these bitmaps, or
2331 remove a write-intent bitmap from such an array.
2332 .PP
2333
2334 Using GROW on containers is currently supported only for Intel's IMSM
2335 container format. The number of devices in a container can be
2336 increased - which affects all arrays in the container - or an array
2337 in a container can be converted between levels where those levels are
2338 supported by the container, and the conversion is on of those listed
2339 above. Resizing arrays in an IMSM container with
2340 .B "--grow --size"
2341 is not yet supported.
2342
2343 Grow functionality (e.g. expand a number of raid devices) for Intel's
2344 IMSM container format has an experimental status. It is guarded by the
2345 .B MDADM_EXPERIMENTAL
2346 environment variable which must be set to '1' for a GROW command to
2347 succeed.
2348 This is for the following reasons:
2349
2350 .IP 1.
2351 Intel's native IMSM check-pointing is not fully tested yet.
2352 This can causes IMSM incompatibility during the grow process: an array
2353 which is growing cannot roam between Microsoft Windows(R) and Linux
2354 systems.
2355
2356 .IP 2.
2357 Interrupting a grow operation is not recommended, because it
2358 has not been fully tested for Intel's IMSM container format yet.
2359
2360 .PP
2361 Note: Intel's native checkpointing doesn't use
2362 .B --backup-file
2363 option and it is transparent for assembly feature.
2364
2365 .SS SIZE CHANGES
2366 Normally when an array is built the "size" is taken from the smallest
2367 of the drives. If all the small drives in an arrays are, one at a
2368 time, removed and replaced with larger drives, then you could have an
2369 array of large drives with only a small amount used. In this
2370 situation, changing the "size" with "GROW" mode will allow the extra
2371 space to start being used. If the size is increased in this way, a
2372 "resync" process will start to make sure the new parts of the array
2373 are synchronised.
2374
2375 Note that when an array changes size, any filesystem that may be
2376 stored in the array will not automatically grow or shrink to use or
2377 vacate the space. The
2378 filesystem will need to be explicitly told to use the extra space
2379 after growing, or to reduce its size
2380 .B prior
2381 to shrinking the array.
2382
2383 Also the size of an array cannot be changed while it has an active
2384 bitmap. If an array has a bitmap, it must be removed before the size
2385 can be changed. Once the change is complete a new bitmap can be created.
2386
2387 .SS RAID\-DEVICES CHANGES
2388
2389 A RAID1 array can work with any number of devices from 1 upwards
2390 (though 1 is not very useful). There may be times which you want to
2391 increase or decrease the number of active devices. Note that this is
2392 different to hot-add or hot-remove which changes the number of
2393 inactive devices.
2394
2395 When reducing the number of devices in a RAID1 array, the slots which
2396 are to be removed from the array must already be vacant. That is, the
2397 devices which were in those slots must be failed and removed.
2398
2399 When the number of devices is increased, any hot spares that are
2400 present will be activated immediately.
2401
2402 Changing the number of active devices in a RAID5 or RAID6 is much more
2403 effort. Every block in the array will need to be read and written
2404 back to a new location. From 2.6.17, the Linux Kernel is able to
2405 increase the number of devices in a RAID5 safely, including restarting
2406 an interrupted "reshape". From 2.6.31, the Linux Kernel is able to
2407 increase or decrease the number of devices in a RAID5 or RAID6.
2408
2409 From 2.6.35, the Linux Kernel is able to convert a RAID0 in to a RAID4
2410 or RAID5.
2411 .I mdadm
2412 uses this functionality and the ability to add
2413 devices to a RAID4 to allow devices to be added to a RAID0. When
2414 requested to do this,
2415 .I mdadm
2416 will convert the RAID0 to a RAID4, add the necessary disks and make
2417 the reshape happen, and then convert the RAID4 back to RAID0.
2418
2419 When decreasing the number of devices, the size of the array will also
2420 decrease. If there was data in the array, it could get destroyed and
2421 this is not reversible, so you should firstly shrink the filesystem on
2422 the array to fit within the new size. To help prevent accidents,
2423 .I mdadm
2424 requires that the size of the array be decreased first with
2425 .BR "mdadm --grow --array-size" .
2426 This is a reversible change which simply makes the end of the array
2427 inaccessible. The integrity of any data can then be checked before
2428 the non-reversible reduction in the number of devices is request.
2429
2430 When relocating the first few stripes on a RAID5 or RAID6, it is not
2431 possible to keep the data on disk completely consistent and
2432 crash-proof. To provide the required safety, mdadm disables writes to
2433 the array while this "critical section" is reshaped, and takes a
2434 backup of the data that is in that section. For grows, this backup may be
2435 stored in any spare devices that the array has, however it can also be
2436 stored in a separate file specified with the
2437 .B \-\-backup\-file
2438 option, and is required to be specified for shrinks, RAID level
2439 changes and layout changes. If this option is used, and the system
2440 does crash during the critical period, the same file must be passed to
2441 .B \-\-assemble
2442 to restore the backup and reassemble the array. When shrinking rather
2443 than growing the array, the reshape is done from the end towards the
2444 beginning, so the "critical section" is at the end of the reshape.
2445
2446 .SS LEVEL CHANGES
2447
2448 Changing the RAID level of any array happens instantaneously. However
2449 in the RAID5 to RAID6 case this requires a non-standard layout of the
2450 RAID6 data, and in the RAID6 to RAID5 case that non-standard layout is
2451 required before the change can be accomplished. So while the level
2452 change is instant, the accompanying layout change can take quite a
2453 long time. A
2454 .B \-\-backup\-file
2455 is required. If the array is not simultaneously being grown or
2456 shrunk, so that the array size will remain the same - for example,
2457 reshaping a 3-drive RAID5 into a 4-drive RAID6 - the backup file will
2458 be used not just for a "cricital section" but throughout the reshape
2459 operation, as described below under LAYOUT CHANGES.
2460
2461 .SS CHUNK-SIZE AND LAYOUT CHANGES
2462
2463 Changing the chunk-size of layout without also changing the number of
2464 devices as the same time will involve re-writing all blocks in-place.
2465 To ensure against data loss in the case of a crash, a
2466 .B --backup-file
2467 must be provided for these changes. Small sections of the array will
2468 be copied to the backup file while they are being rearranged. This
2469 means that all the data is copied twice, once to the backup and once
2470 to the new layout on the array, so this type of reshape will go very
2471 slowly.
2472
2473 If the reshape is interrupted for any reason, this backup file must be
2474 made available to
2475 .B "mdadm --assemble"
2476 so the array can be reassembled. Consequently the file cannot be
2477 stored on the device being reshaped.
2478
2479
2480 .SS BITMAP CHANGES
2481
2482 A write-intent bitmap can be added to, or removed from, an active
2483 array. Either internal bitmaps, or bitmaps stored in a separate file,
2484 can be added. Note that if you add a bitmap stored in a file which is
2485 in a filesystem that is on the RAID array being affected, the system
2486 will deadlock. The bitmap must be on a separate filesystem.
2487
2488 .SH INCREMENTAL MODE
2489
2490 .HP 12
2491 Usage:
2492 .B mdadm \-\-incremental
2493 .RB [ \-\-run ]
2494 .RB [ \-\-quiet ]
2495 .I component-device
2496 .HP 12
2497 Usage:
2498 .B mdadm \-\-incremental \-\-fail
2499 .I component-device
2500 .HP 12
2501 Usage:
2502 .B mdadm \-\-incremental \-\-rebuild\-map
2503 .HP 12
2504 Usage:
2505 .B mdadm \-\-incremental \-\-run \-\-scan
2506
2507 .PP
2508 This mode is designed to be used in conjunction with a device
2509 discovery system. As devices are found in a system, they can be
2510 passed to
2511 .B "mdadm \-\-incremental"
2512 to be conditionally added to an appropriate array.
2513
2514 Conversely, it can also be used with the
2515 .B \-\-fail
2516 flag to do just the opposite and find whatever array a particular device
2517 is part of and remove the device from that array.
2518
2519 If the device passed is a
2520 .B CONTAINER
2521 device created by a previous call to
2522 .IR mdadm ,
2523 then rather than trying to add that device to an array, all the arrays
2524 described by the metadata of the container will be started.
2525
2526 .I mdadm
2527 performs a number of tests to determine if the device is part of an
2528 array, and which array it should be part of. If an appropriate array
2529 is found, or can be created,
2530 .I mdadm
2531 adds the device to the array and conditionally starts the array.
2532
2533 Note that
2534 .I mdadm
2535 will normally only add devices to an array which were previously working
2536 (active or spare) parts of that array. The support for automatic
2537 inclusion of a new drive as a spare in some array requires
2538 a configuration through POLICY in config file.
2539
2540 The tests that
2541 .I mdadm
2542 makes are as follow:
2543 .IP +
2544 Is the device permitted by
2545 .BR mdadm.conf ?
2546 That is, is it listed in a
2547 .B DEVICES
2548 line in that file. If
2549 .B DEVICES
2550 is absent then the default it to allow any device. Similar if
2551 .B DEVICES
2552 contains the special word
2553 .B partitions
2554 then any device is allowed. Otherwise the device name given to
2555 .I mdadm
2556 must match one of the names or patterns in a
2557 .B DEVICES
2558 line.
2559
2560 .IP +
2561 Does the device have a valid md superblock? If a specific metadata
2562 version is requested with
2563 .B \-\-metadata
2564 or
2565 .B \-e
2566 then only that style of metadata is accepted, otherwise
2567 .I mdadm
2568 finds any known version of metadata. If no
2569 .I md
2570 metadata is found, the device may be still added to an array
2571 as a spare if POLICY allows.
2572
2573 .ig
2574 .IP +
2575 Does the metadata match an expected array?
2576 The metadata can match in two ways. Either there is an array listed
2577 in
2578 .B mdadm.conf
2579 which identifies the array (either by UUID, by name, by device list,
2580 or by minor-number), or the array was created with a
2581 .B homehost
2582 specified and that
2583 .B homehost
2584 matches the one in
2585 .B mdadm.conf
2586 or on the command line.
2587 If
2588 .I mdadm
2589 is not able to positively identify the array as belonging to the
2590 current host, the device will be rejected.
2591 ..
2592
2593 .PP
2594 .I mdadm
2595 keeps a list of arrays that it has partially assembled in
2596 .BR {MAP_PATH} .
2597 If no array exists which matches
2598 the metadata on the new device,
2599 .I mdadm
2600 must choose a device name and unit number. It does this based on any
2601 name given in
2602 .B mdadm.conf
2603 or any name information stored in the metadata. If this name
2604 suggests a unit number, that number will be used, otherwise a free
2605 unit number will be chosen. Normally
2606 .I mdadm
2607 will prefer to create a partitionable array, however if the
2608 .B CREATE
2609 line in
2610 .B mdadm.conf
2611 suggests that a non-partitionable array is preferred, that will be
2612 honoured.
2613
2614 If the array is not found in the config file and its metadata does not
2615 identify it as belonging to the "homehost", then
2616 .I mdadm
2617 will choose a name for the array which is certain not to conflict with
2618 any array which does belong to this host. It does this be adding an
2619 underscore and a small number to the name preferred by the metadata.
2620
2621 Once an appropriate array is found or created and the device is added,
2622 .I mdadm
2623 must decide if the array is ready to be started. It will
2624 normally compare the number of available (non-spare) devices to the
2625 number of devices that the metadata suggests need to be active. If
2626 there are at least that many, the array will be started. This means
2627 that if any devices are missing the array will not be restarted.
2628
2629 As an alternative,
2630 .B \-\-run
2631 may be passed to
2632 .I mdadm
2633 in which case the array will be run as soon as there are enough
2634 devices present for the data to be accessible. For a RAID1, that
2635 means one device will start the array. For a clean RAID5, the array
2636 will be started as soon as all but one drive is present.
2637
2638 Note that neither of these approaches is really ideal. If it can
2639 be known that all device discovery has completed, then
2640 .br
2641 .B " mdadm \-IRs"
2642 .br
2643 can be run which will try to start all arrays that are being
2644 incrementally assembled. They are started in "read-auto" mode in
2645 which they are read-only until the first write request. This means
2646 that no metadata updates are made and no attempt at resync or recovery
2647 happens. Further devices that are found before the first write can
2648 still be added safely.
2649
2650 .SH ENVIRONMENT
2651 This section describes environment variables that affect how mdadm
2652 operates.
2653
2654 .TP
2655 .B MDADM_NO_MDMON
2656 Setting this value to 1 will prevent mdadm from automatically launching
2657 mdmon. This variable is intended primarily for debugging mdadm/mdmon.
2658
2659 .TP
2660 .B MDADM_NO_UDEV
2661 Normally,
2662 .I mdadm
2663 does not create any device nodes in /dev, but leaves that task to
2664 .IR udev .
2665 If
2666 .I udev
2667 appears not to be configured, or if this environment variable is set
2668 to '1', the
2669 .I mdadm
2670 will create and devices that are needed.
2671
2672 .SH EXAMPLES
2673
2674 .B " mdadm \-\-query /dev/name-of-device"
2675 .br
2676 This will find out if a given device is a RAID array, or is part of
2677 one, and will provide brief information about the device.
2678
2679 .B " mdadm \-\-assemble \-\-scan"
2680 .br
2681 This will assemble and start all arrays listed in the standard config
2682 file. This command will typically go in a system startup file.
2683
2684 .B " mdadm \-\-stop \-\-scan"
2685 .br
2686 This will shut down all arrays that can be shut down (i.e. are not
2687 currently in use). This will typically go in a system shutdown script.
2688
2689 .B " mdadm \-\-follow \-\-scan \-\-delay=120"
2690 .br
2691 If (and only if) there is an Email address or program given in the
2692 standard config file, then
2693 monitor the status of all arrays listed in that file by
2694 polling them ever 2 minutes.
2695
2696 .B " mdadm \-\-create /dev/md0 \-\-level=1 \-\-raid\-devices=2 /dev/hd[ac]1"
2697 .br
2698 Create /dev/md0 as a RAID1 array consisting of /dev/hda1 and /dev/hdc1.
2699
2700 .br
2701 .B " echo 'DEVICE /dev/hd*[0\-9] /dev/sd*[0\-9]' > mdadm.conf"
2702 .br
2703 .B " mdadm \-\-detail \-\-scan >> mdadm.conf"
2704 .br
2705 This will create a prototype config file that describes currently
2706 active arrays that are known to be made from partitions of IDE or SCSI drives.
2707 This file should be reviewed before being used as it may
2708 contain unwanted detail.
2709
2710 .B " echo 'DEVICE /dev/hd[a\-z] /dev/sd*[a\-z]' > mdadm.conf"
2711 .br
2712 .B " mdadm \-\-examine \-\-scan \-\-config=mdadm.conf >> mdadm.conf"
2713 .br
2714 This will find arrays which could be assembled from existing IDE and
2715 SCSI whole drives (not partitions), and store the information in the
2716 format of a config file.
2717 This file is very likely to contain unwanted detail, particularly
2718 the
2719 .B devices=
2720 entries. It should be reviewed and edited before being used as an
2721 actual config file.
2722
2723 .B " mdadm \-\-examine \-\-brief \-\-scan \-\-config=partitions"
2724 .br
2725 .B " mdadm \-Ebsc partitions"
2726 .br
2727 Create a list of devices by reading
2728 .BR /proc/partitions ,
2729 scan these for RAID superblocks, and printout a brief listing of all
2730 that were found.
2731
2732 .B " mdadm \-Ac partitions \-m 0 /dev/md0"
2733 .br
2734 Scan all partitions and devices listed in
2735 .BR /proc/partitions
2736 and assemble
2737 .B /dev/md0
2738 out of all such devices with a RAID superblock with a minor number of 0.
2739
2740 .B " mdadm \-\-monitor \-\-scan \-\-daemonise > /run/mdadm/mon.pid"
2741 .br
2742 If config file contains a mail address or alert program, run mdadm in
2743 the background in monitor mode monitoring all md devices. Also write
2744 pid of mdadm daemon to
2745 .BR /run/mdadm/mon.pid .
2746
2747 .B " mdadm \-Iq /dev/somedevice"
2748 .br
2749 Try to incorporate newly discovered device into some array as
2750 appropriate.
2751
2752 .B " mdadm \-\-incremental \-\-rebuild\-map \-\-run \-\-scan"
2753 .br
2754 Rebuild the array map from any current arrays, and then start any that
2755 can be started.
2756
2757 .B " mdadm /dev/md4 --fail detached --remove detached"
2758 .br
2759 Any devices which are components of /dev/md4 will be marked as faulty
2760 and then remove from the array.
2761
2762 .B " mdadm --grow /dev/md4 --level=6 --backup-file=/root/backup-md4"
2763 .br
2764 The array
2765 .B /dev/md4
2766 which is currently a RAID5 array will be converted to RAID6. There
2767 should normally already be a spare drive attached to the array as a
2768 RAID6 needs one more drive than a matching RAID5.
2769
2770 .B " mdadm --create /dev/md/ddf --metadata=ddf --raid-disks 6 /dev/sd[a-f]"
2771 .br
2772 Create a DDF array over 6 devices.
2773
2774 .B " mdadm --create /dev/md/home -n3 -l5 -z 30000000 /dev/md/ddf"
2775 .br
2776 Create a RAID5 array over any 3 devices in the given DDF set. Use
2777 only 30 gigabytes of each device.
2778
2779 .B " mdadm -A /dev/md/ddf1 /dev/sd[a-f]"
2780 .br
2781 Assemble a pre-exist ddf array.
2782
2783 .B " mdadm -I /dev/md/ddf1"
2784 .br
2785 Assemble all arrays contained in the ddf array, assigning names as
2786 appropriate.
2787
2788 .B " mdadm \-\-create \-\-help"
2789 .br
2790 Provide help about the Create mode.
2791
2792 .B " mdadm \-\-config \-\-help"
2793 .br
2794 Provide help about the format of the config file.
2795
2796 .B " mdadm \-\-help"
2797 .br
2798 Provide general help.
2799
2800 .SH FILES
2801
2802 .SS /proc/mdstat
2803
2804 If you're using the
2805 .B /proc
2806 filesystem,
2807 .B /proc/mdstat
2808 lists all active md devices with information about them.
2809 .I mdadm
2810 uses this to find arrays when
2811 .B \-\-scan
2812 is given in Misc mode, and to monitor array reconstruction
2813 on Monitor mode.
2814
2815 .SS /etc/mdadm.conf
2816
2817 The config file lists which devices may be scanned to see if
2818 they contain MD super block, and gives identifying information
2819 (e.g. UUID) about known MD arrays. See
2820 .BR mdadm.conf (5)
2821 for more details.
2822
2823 .SS {MAP_PATH}
2824 When
2825 .B \-\-incremental
2826 mode is used, this file gets a list of arrays currently being created.
2827
2828 .SH DEVICE NAMES
2829
2830 .I mdadm
2831 understand two sorts of names for array devices.
2832
2833 The first is the so-called 'standard' format name, which matches the
2834 names used by the kernel and which appear in
2835 .IR /proc/mdstat .
2836
2837 The second sort can be freely chosen, but must reside in
2838 .IR /dev/md/ .
2839 When giving a device name to
2840 .I mdadm
2841 to create or assemble an array, either full path name such as
2842 .I /dev/md0
2843 or
2844 .I /dev/md/home
2845 can be given, or just the suffix of the second sort of name, such as
2846 .I home
2847 can be given.
2848
2849 When
2850 .I mdadm
2851 chooses device names during auto-assembly or incremental assembly, it
2852 will sometimes add a small sequence number to the end of the name to
2853 avoid conflicted between multiple arrays that have the same name. If
2854 .I mdadm
2855 can reasonably determine that the array really is meant for this host,
2856 either by a hostname in the metadata, or by the presence of the array
2857 in
2858 .BR mdadm.conf ,
2859 then it will leave off the suffix if possible.
2860 Also if the homehost is specified as
2861 .B <ignore>
2862 .I mdadm
2863 will only use a suffix if a different array of the same name already
2864 exists or is listed in the config file.
2865
2866 The standard names for non-partitioned arrays (the only sort of md
2867 array available in 2.4 and earlier) are of the form
2868 .IP
2869 /dev/mdNN
2870 .PP
2871 where NN is a number.
2872 The standard names for partitionable arrays (as available from 2.6
2873 onwards) are of the form
2874 .IP
2875 /dev/md_dNN
2876 .PP
2877 Partition numbers should be indicated by added "pMM" to these, thus "/dev/md/d1p2".
2878 .PP
2879 From kernel version, 2.6.28 the "non-partitioned array" can actually
2880 be partitioned. So the "md_dNN" names are no longer needed, and
2881 partitions such as "/dev/mdNNpXX" are possible.
2882
2883 .SH NOTE
2884 .I mdadm
2885 was previously known as
2886 .IR mdctl .
2887 .P
2888 .I mdadm
2889 is completely separate from the
2890 .I raidtools
2891 package, and does not use the
2892 .I /etc/raidtab
2893 configuration file at all.
2894
2895 .SH SEE ALSO
2896 For further information on mdadm usage, MD and the various levels of
2897 RAID, see:
2898 .IP
2899 .B http://raid.wiki.kernel.org/
2900 .PP
2901 (based upon Jakob \(/Ostergaard's Software\-RAID.HOWTO)
2902 .\".PP
2903 .\"for new releases of the RAID driver check out:
2904 .\"
2905 .\".IP
2906 .\".UR ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2907 .\"ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2908 .\".UE
2909 .\".PP
2910 .\"or
2911 .\".IP
2912 .\".UR http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2913 .\"http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2914 .\".UE
2915 .PP
2916 The latest version of
2917 .I mdadm
2918 should always be available from
2919 .IP
2920 .B http://www.kernel.org/pub/linux/utils/raid/mdadm/
2921 .PP
2922 Related man pages:
2923 .PP
2924 .IR mdmon (8),
2925 .IR mdadm.conf (5),
2926 .IR md (4).
2927 .PP
2928 .IR raidtab (5),
2929 .IR raid0run (8),
2930 .IR raidstop (8),
2931 .IR mkraid (8).