]> git.ipfire.org Git - thirdparty/mdadm.git/blob - mdadm.8.in
Bad block log
[thirdparty/mdadm.git] / mdadm.8.in
1 .\" -*- nroff -*-
2 .\" Copyright Neil Brown and others.
3 .\" This program is free software; you can redistribute it and/or modify
4 .\" it under the terms of the GNU General Public License as published by
5 .\" the Free Software Foundation; either version 2 of the License, or
6 .\" (at your option) any later version.
7 .\" See file COPYING in distribution for details.
8 .TH MDADM 8 "" v3.2.5
9 .SH NAME
10 mdadm \- manage MD devices
11 .I aka
12 Linux Software RAID
13
14 .SH SYNOPSIS
15
16 .BI mdadm " [mode] <raiddevice> [options] <component-devices>"
17
18 .SH DESCRIPTION
19 RAID devices are virtual devices created from two or more
20 real block devices. This allows multiple devices (typically disk
21 drives or partitions thereof) to be combined into a single device to
22 hold (for example) a single filesystem.
23 Some RAID levels include redundancy and so can survive some degree of
24 device failure.
25
26 Linux Software RAID devices are implemented through the md (Multiple
27 Devices) device driver.
28
29 Currently, Linux supports
30 .B LINEAR
31 md devices,
32 .B RAID0
33 (striping),
34 .B RAID1
35 (mirroring),
36 .BR RAID4 ,
37 .BR RAID5 ,
38 .BR RAID6 ,
39 .BR RAID10 ,
40 .BR MULTIPATH ,
41 .BR FAULTY ,
42 and
43 .BR CONTAINER .
44
45 .B MULTIPATH
46 is not a Software RAID mechanism, but does involve
47 multiple devices:
48 each device is a path to one common physical storage device.
49 New installations should not use md/multipath as it is not well
50 supported and has no ongoing development. Use the Device Mapper based
51 multipath-tools instead.
52
53 .B FAULTY
54 is also not true RAID, and it only involves one device. It
55 provides a layer over a true device that can be used to inject faults.
56
57 .B CONTAINER
58 is different again. A
59 .B CONTAINER
60 is a collection of devices that are
61 managed as a set. This is similar to the set of devices connected to
62 a hardware RAID controller. The set of devices may contain a number
63 of different RAID arrays each utilising some (or all) of the blocks from a
64 number of the devices in the set. For example, two devices in a 5-device set
65 might form a RAID1 using the whole devices. The remaining three might
66 have a RAID5 over the first half of each device, and a RAID0 over the
67 second half.
68
69 With a
70 .BR CONTAINER ,
71 there is one set of metadata that describes all of
72 the arrays in the container. So when
73 .I mdadm
74 creates a
75 .B CONTAINER
76 device, the device just represents the metadata. Other normal arrays (RAID1
77 etc) can be created inside the container.
78
79 .SH MODES
80 mdadm has several major modes of operation:
81 .TP
82 .B Assemble
83 Assemble the components of a previously created
84 array into an active array. Components can be explicitly given
85 or can be searched for.
86 .I mdadm
87 checks that the components
88 do form a bona fide array, and can, on request, fiddle superblock
89 information so as to assemble a faulty array.
90
91 .TP
92 .B Build
93 Build an array that doesn't have per-device metadata (superblocks). For these
94 sorts of arrays,
95 .I mdadm
96 cannot differentiate between initial creation and subsequent assembly
97 of an array. It also cannot perform any checks that appropriate
98 components have been requested. Because of this, the
99 .B Build
100 mode should only be used together with a complete understanding of
101 what you are doing.
102
103 .TP
104 .B Create
105 Create a new array with per-device metadata (superblocks).
106 Appropriate metadata is written to each device, and then the array
107 comprising those devices is activated. A 'resync' process is started
108 to make sure that the array is consistent (e.g. both sides of a mirror
109 contain the same data) but the content of the device is left otherwise
110 untouched.
111 The array can be used as soon as it has been created. There is no
112 need to wait for the initial resync to finish.
113
114 .TP
115 .B "Follow or Monitor"
116 Monitor one or more md devices and act on any state changes. This is
117 only meaningful for RAID1, 4, 5, 6, 10 or multipath arrays, as
118 only these have interesting state. RAID0 or Linear never have
119 missing, spare, or failed drives, so there is nothing to monitor.
120
121 .TP
122 .B "Grow"
123 Grow (or shrink) an array, or otherwise reshape it in some way.
124 Currently supported growth options including changing the active size
125 of component devices and changing the number of active devices in
126 Linear and RAID levels 0/1/4/5/6,
127 changing the RAID level between 0, 1, 5, and 6, and between 0 and 10,
128 changing the chunk size and layout for RAID 0,4,5,6, as well as adding or
129 removing a write-intent bitmap.
130
131 .TP
132 .B "Incremental Assembly"
133 Add a single device to an appropriate array. If the addition of the
134 device makes the array runnable, the array will be started.
135 This provides a convenient interface to a
136 .I hot-plug
137 system. As each device is detected,
138 .I mdadm
139 has a chance to include it in some array as appropriate.
140 Optionally, when the
141 .I \-\-fail
142 flag is passed in we will remove the device from any active array
143 instead of adding it.
144
145 If a
146 .B CONTAINER
147 is passed to
148 .I mdadm
149 in this mode, then any arrays within that container will be assembled
150 and started.
151
152 .TP
153 .B Manage
154 This is for doing things to specific components of an array such as
155 adding new spares and removing faulty devices.
156
157 .TP
158 .B Misc
159 This is an 'everything else' mode that supports operations on active
160 arrays, operations on component devices such as erasing old superblocks, and
161 information gathering operations.
162 .\"This mode allows operations on independent devices such as examine MD
163 .\"superblocks, erasing old superblocks and stopping active arrays.
164
165 .TP
166 .B Auto-detect
167 This mode does not act on a specific device or array, but rather it
168 requests the Linux Kernel to activate any auto-detected arrays.
169 .SH OPTIONS
170
171 .SH Options for selecting a mode are:
172
173 .TP
174 .BR \-A ", " \-\-assemble
175 Assemble a pre-existing array.
176
177 .TP
178 .BR \-B ", " \-\-build
179 Build a legacy array without superblocks.
180
181 .TP
182 .BR \-C ", " \-\-create
183 Create a new array.
184
185 .TP
186 .BR \-F ", " \-\-follow ", " \-\-monitor
187 Select
188 .B Monitor
189 mode.
190
191 .TP
192 .BR \-G ", " \-\-grow
193 Change the size or shape of an active array.
194
195 .TP
196 .BR \-I ", " \-\-incremental
197 Add/remove a single device to/from an appropriate array, and possibly start the array.
198
199 .TP
200 .B \-\-auto-detect
201 Request that the kernel starts any auto-detected arrays. This can only
202 work if
203 .I md
204 is compiled into the kernel \(em not if it is a module.
205 Arrays can be auto-detected by the kernel if all the components are in
206 primary MS-DOS partitions with partition type
207 .BR FD ,
208 and all use v0.90 metadata.
209 In-kernel autodetect is not recommended for new installations. Using
210 .I mdadm
211 to detect and assemble arrays \(em possibly in an
212 .I initrd
213 \(em is substantially more flexible and should be preferred.
214
215 .P
216 If a device is given before any options, or if the first option is
217 .BR \-\-add ,
218 .BR \-\-fail ,
219 or
220 .BR \-\-remove ,
221 then the MANAGE mode is assumed.
222 Anything other than these will cause the
223 .B Misc
224 mode to be assumed.
225
226 .SH Options that are not mode-specific are:
227
228 .TP
229 .BR \-h ", " \-\-help
230 Display general help message or, after one of the above options, a
231 mode-specific help message.
232
233 .TP
234 .B \-\-help\-options
235 Display more detailed help about command line parsing and some commonly
236 used options.
237
238 .TP
239 .BR \-V ", " \-\-version
240 Print version information for mdadm.
241
242 .TP
243 .BR \-v ", " \-\-verbose
244 Be more verbose about what is happening. This can be used twice to be
245 extra-verbose.
246 The extra verbosity currently only affects
247 .B \-\-detail \-\-scan
248 and
249 .BR "\-\-examine \-\-scan" .
250
251 .TP
252 .BR \-q ", " \-\-quiet
253 Avoid printing purely informative messages. With this,
254 .I mdadm
255 will be silent unless there is something really important to report.
256
257 .TP
258 .BR \-\-offroot
259 Set first character of argv[0] to @ to indicate mdadm was launched
260 from initrd/initramfs and should not be shutdown by systemd as part of
261 the regular shutdown process. This option is normally only used by
262 the system's initscripts. Please see here for more details on how
263 systemd handled argv[0]:
264 .IP
265 .B http://www.freedesktop.org/wiki/Software/systemd/RootStorageDaemons
266 .PP
267
268
269 .TP
270 .BR \-f ", " \-\-force
271 Be more forceful about certain operations. See the various modes for
272 the exact meaning of this option in different contexts.
273
274 .TP
275 .BR \-c ", " \-\-config=
276 Specify the config file. Default is to use
277 .BR /etc/mdadm.conf ,
278 or if that is missing then
279 .BR /etc/mdadm/mdadm.conf .
280 If the config file given is
281 .B "partitions"
282 then nothing will be read, but
283 .I mdadm
284 will act as though the config file contained exactly
285 .B "DEVICE partitions containers"
286 and will read
287 .B /proc/partitions
288 to find a list of devices to scan, and
289 .B /proc/mdstat
290 to find a list of containers to examine.
291 If the word
292 .B "none"
293 is given for the config file, then
294 .I mdadm
295 will act as though the config file were empty.
296
297 .TP
298 .BR \-s ", " \-\-scan
299 Scan config file or
300 .B /proc/mdstat
301 for missing information.
302 In general, this option gives
303 .I mdadm
304 permission to get any missing information (like component devices,
305 array devices, array identities, and alert destination) from the
306 configuration file (see previous option);
307 one exception is MISC mode when using
308 .B \-\-detail
309 or
310 .B \-\-stop,
311 in which case
312 .B \-\-scan
313 says to get a list of array devices from
314 .BR /proc/mdstat .
315
316 .TP
317 .BR \-e ", " \-\-metadata=
318 Declare the style of RAID metadata (superblock) to be used. The
319 default is {DEFAULT_METADATA} for
320 .BR \-\-create ,
321 and to guess for other operations.
322 The default can be overridden by setting the
323 .B metadata
324 value for the
325 .B CREATE
326 keyword in
327 .BR mdadm.conf .
328
329 Options are:
330 .RS
331 .ie '{DEFAULT_METADATA}'0.90'
332 .IP "0, 0.90, default"
333 .el
334 .IP "0, 0.90"
335 ..
336 Use the original 0.90 format superblock. This format limits arrays to
337 28 component devices and limits component devices of levels 1 and
338 greater to 2 terabytes. It is also possible for there to be confusion
339 about whether the superblock applies to a whole device or just the
340 last partition, if that partition starts on a 64K boundary.
341 .ie '{DEFAULT_METADATA}'0.90'
342 .IP "1, 1.0, 1.1, 1.2"
343 .el
344 .IP "1, 1.0, 1.1, 1.2 default"
345 ..
346 Use the new version-1 format superblock. This has fewer restrictions.
347 It can easily be moved between hosts with different endian-ness, and a
348 recovery operation can be checkpointed and restarted. The different
349 sub-versions store the superblock at different locations on the
350 device, either at the end (for 1.0), at the start (for 1.1) or 4K from
351 the start (for 1.2). "1" is equivalent to "1.2" (the commonly
352 preferred 1.x format).
353 'if '{DEFAULT_METADATA}'1.2' "default" is equivalent to "1.2".
354 .IP ddf
355 Use the "Industry Standard" DDF (Disk Data Format) format defined by
356 SNIA.
357 When creating a DDF array a
358 .B CONTAINER
359 will be created, and normal arrays can be created in that container.
360 .IP imsm
361 Use the Intel(R) Matrix Storage Manager metadata format. This creates a
362 .B CONTAINER
363 which is managed in a similar manner to DDF, and is supported by an
364 option-rom on some platforms:
365 .IP
366 .B http://www.intel.com/design/chipsets/matrixstorage_sb.htm
367 .PP
368 .RE
369
370 .TP
371 .B \-\-homehost=
372 This will override any
373 .B HOMEHOST
374 setting in the config file and provides the identity of the host which
375 should be considered the home for any arrays.
376
377 When creating an array, the
378 .B homehost
379 will be recorded in the metadata. For version-1 superblocks, it will
380 be prefixed to the array name. For version-0.90 superblocks, part of
381 the SHA1 hash of the hostname will be stored in the later half of the
382 UUID.
383
384 When reporting information about an array, any array which is tagged
385 for the given homehost will be reported as such.
386
387 When using Auto-Assemble, only arrays tagged for the given homehost
388 will be allowed to use 'local' names (i.e. not ending in '_' followed
389 by a digit string). See below under
390 .BR "Auto Assembly" .
391
392 .TP
393 .B \-\-prefer=
394 When
395 .I mdadm
396 needs to print the name for a device it normally finds the name in
397 .B /dev
398 which refers to the device and is shortest. When a path component is
399 given with
400 .B \-\-prefer
401 .I mdadm
402 will prefer a longer name if it contains that component. For example
403 .B \-\-prefer=by-uuid
404 will prefer a name in a subdirectory of
405 .B /dev
406 called
407 .BR by-uuid .
408
409 This functionality is currently only provided by
410 .B \-\-detail
411 and
412 .BR \-\-monitor .
413
414 .SH For create, build, or grow:
415
416 .TP
417 .BR \-n ", " \-\-raid\-devices=
418 Specify the number of active devices in the array. This, plus the
419 number of spare devices (see below) must equal the number of
420 .I component-devices
421 (including "\fBmissing\fP" devices)
422 that are listed on the command line for
423 .BR \-\-create .
424 Setting a value of 1 is probably
425 a mistake and so requires that
426 .B \-\-force
427 be specified first. A value of 1 will then be allowed for linear,
428 multipath, RAID0 and RAID1. It is never allowed for RAID4, RAID5 or RAID6.
429 .br
430 This number can only be changed using
431 .B \-\-grow
432 for RAID1, RAID4, RAID5 and RAID6 arrays, and only on kernels which provide
433 the necessary support.
434
435 .TP
436 .BR \-x ", " \-\-spare\-devices=
437 Specify the number of spare (eXtra) devices in the initial array.
438 Spares can also be added
439 and removed later. The number of component devices listed
440 on the command line must equal the number of RAID devices plus the
441 number of spare devices.
442
443 .TP
444 .BR \-z ", " \-\-size=
445 Amount (in Kibibytes) of space to use from each drive in RAID levels 1/4/5/6.
446 This must be a multiple of the chunk size, and must leave about 128Kb
447 of space at the end of the drive for the RAID superblock.
448 If this is not specified
449 (as it normally is not) the smallest drive (or partition) sets the
450 size, though if there is a variance among the drives of greater than 1%, a warning is
451 issued.
452
453 A suffix of 'M' or 'G' can be given to indicate Megabytes or
454 Gigabytes respectively.
455
456 Sometimes a replacement drive can be a little smaller than the
457 original drives though this should be minimised by IDEMA standards.
458 Such a replacement drive will be rejected by
459 .IR md .
460 To guard against this it can be useful to set the initial size
461 slightly smaller than the smaller device with the aim that it will
462 still be larger than any replacement.
463
464 This value can be set with
465 .B \-\-grow
466 for RAID level 1/4/5/6 though
467 .B CONTAINER
468 based arrays such as those with IMSM metadata may not be able to
469 support this.
470 If the array was created with a size smaller than the currently
471 active drives, the extra space can be accessed using
472 .BR \-\-grow .
473 The size can be given as
474 .B max
475 which means to choose the largest size that fits on all current drives.
476
477 Before reducing the size of the array (with
478 .BR "\-\-grow \-\-size=" )
479 you should make sure that space isn't needed. If the device holds a
480 filesystem, you would need to resize the filesystem to use less space.
481
482 After reducing the array size you should check that the data stored in
483 the device is still available. If the device holds a filesystem, then
484 an 'fsck' of the filesystem is a minimum requirement. If there are
485 problems the array can be made bigger again with no loss with another
486 .B "\-\-grow \-\-size="
487 command.
488
489 This value cannot be used when creating a
490 .B CONTAINER
491 such as with DDF and IMSM metadata, though it perfectly valid when
492 creating an array inside a container.
493
494 .TP
495 .BR \-Z ", " \-\-array\-size=
496 This is only meaningful with
497 .B \-\-grow
498 and its effect is not persistent: when the array is stopped and
499 restarted the default array size will be restored.
500
501 Setting the array-size causes the array to appear smaller to programs
502 that access the data. This is particularly needed before reshaping an
503 array so that it will be smaller. As the reshape is not reversible,
504 but setting the size with
505 .B \-\-array-size
506 is, it is required that the array size is reduced as appropriate
507 before the number of devices in the array is reduced.
508
509 Before reducing the size of the array you should make sure that space
510 isn't needed. If the device holds a filesystem, you would need to
511 resize the filesystem to use less space.
512
513 After reducing the array size you should check that the data stored in
514 the device is still available. If the device holds a filesystem, then
515 an 'fsck' of the filesystem is a minimum requirement. If there are
516 problems the array can be made bigger again with no loss with another
517 .B "\-\-grow \-\-array\-size="
518 command.
519
520 A suffix of 'M' or 'G' can be given to indicate Megabytes or
521 Gigabytes respectively.
522 A value of
523 .B max
524 restores the apparent size of the array to be whatever the real
525 amount of available space is.
526
527 .TP
528 .BR \-c ", " \-\-chunk=
529 Specify chunk size of kibibytes. The default when creating an
530 array is 512KB. To ensure compatibility with earlier versions, the
531 default when Building and array with no persistent metadata is 64KB.
532 This is only meaningful for RAID0, RAID4, RAID5, RAID6, and RAID10.
533
534 RAID4, RAID5, RAID6, and RAID10 require the chunk size to be a power
535 of 2. In any case it must be a multiple of 4KB.
536
537 A suffix of 'M' or 'G' can be given to indicate Megabytes or
538 Gigabytes respectively.
539
540 .TP
541 .BR \-\-rounding=
542 Specify rounding factor for a Linear array. The size of each
543 component will be rounded down to a multiple of this size.
544 This is a synonym for
545 .B \-\-chunk
546 but highlights the different meaning for Linear as compared to other
547 RAID levels. The default is 64K if a kernel earlier than 2.6.16 is in
548 use, and is 0K (i.e. no rounding) in later kernels.
549
550 .TP
551 .BR \-l ", " \-\-level=
552 Set RAID level. When used with
553 .BR \-\-create ,
554 options are: linear, raid0, 0, stripe, raid1, 1, mirror, raid4, 4,
555 raid5, 5, raid6, 6, raid10, 10, multipath, mp, faulty, container.
556 Obviously some of these are synonymous.
557
558 When a
559 .B CONTAINER
560 metadata type is requested, only the
561 .B container
562 level is permitted, and it does not need to be explicitly given.
563
564 When used with
565 .BR \-\-build ,
566 only linear, stripe, raid0, 0, raid1, multipath, mp, and faulty are valid.
567
568 Can be used with
569 .B \-\-grow
570 to change the RAID level in some cases. See LEVEL CHANGES below.
571
572 .TP
573 .BR \-p ", " \-\-layout=
574 This option configures the fine details of data layout for RAID5, RAID6,
575 and RAID10 arrays, and controls the failure modes for
576 .IR faulty .
577
578 The layout of the RAID5 parity block can be one of
579 .BR left\-asymmetric ,
580 .BR left\-symmetric ,
581 .BR right\-asymmetric ,
582 .BR right\-symmetric ,
583 .BR la ", " ra ", " ls ", " rs .
584 The default is
585 .BR left\-symmetric .
586
587 It is also possible to cause RAID5 to use a RAID4-like layout by
588 choosing
589 .BR parity\-first ,
590 or
591 .BR parity\-last .
592
593 Finally for RAID5 there are DDF\-compatible layouts,
594 .BR ddf\-zero\-restart ,
595 .BR ddf\-N\-restart ,
596 and
597 .BR ddf\-N\-continue .
598
599 These same layouts are available for RAID6. There are also 4 layouts
600 that will provide an intermediate stage for converting between RAID5
601 and RAID6. These provide a layout which is identical to the
602 corresponding RAID5 layout on the first N\-1 devices, and has the 'Q'
603 syndrome (the second 'parity' block used by RAID6) on the last device.
604 These layouts are:
605 .BR left\-symmetric\-6 ,
606 .BR right\-symmetric\-6 ,
607 .BR left\-asymmetric\-6 ,
608 .BR right\-asymmetric\-6 ,
609 and
610 .BR parity\-first\-6 .
611
612 When setting the failure mode for level
613 .I faulty,
614 the options are:
615 .BR write\-transient ", " wt ,
616 .BR read\-transient ", " rt ,
617 .BR write\-persistent ", " wp ,
618 .BR read\-persistent ", " rp ,
619 .BR write\-all ,
620 .BR read\-fixable ", " rf ,
621 .BR clear ", " flush ", " none .
622
623 Each failure mode can be followed by a number, which is used as a period
624 between fault generation. Without a number, the fault is generated
625 once on the first relevant request. With a number, the fault will be
626 generated after that many requests, and will continue to be generated
627 every time the period elapses.
628
629 Multiple failure modes can be current simultaneously by using the
630 .B \-\-grow
631 option to set subsequent failure modes.
632
633 "clear" or "none" will remove any pending or periodic failure modes,
634 and "flush" will clear any persistent faults.
635
636 Finally, the layout options for RAID10 are one of 'n', 'o' or 'f' followed
637 by a small number. The default is 'n2'. The supported options are:
638
639 .I 'n'
640 signals 'near' copies. Multiple copies of one data block are at
641 similar offsets in different devices.
642
643 .I 'o'
644 signals 'offset' copies. Rather than the chunks being duplicated
645 within a stripe, whole stripes are duplicated but are rotated by one
646 device so duplicate blocks are on different devices. Thus subsequent
647 copies of a block are in the next drive, and are one chunk further
648 down.
649
650 .I 'f'
651 signals 'far' copies
652 (multiple copies have very different offsets).
653 See md(4) for more detail about 'near', 'offset', and 'far'.
654
655 The number is the number of copies of each datablock. 2 is normal, 3
656 can be useful. This number can be at most equal to the number of
657 devices in the array. It does not need to divide evenly into that
658 number (e.g. it is perfectly legal to have an 'n2' layout for an array
659 with an odd number of devices).
660
661 When an array is converted between RAID5 and RAID6 an intermediate
662 RAID6 layout is used in which the second parity block (Q) is always on
663 the last device. To convert a RAID5 to RAID6 and leave it in this new
664 layout (which does not require re-striping) use
665 .BR \-\-layout=preserve .
666 This will try to avoid any restriping.
667
668 The converse of this is
669 .B \-\-layout=normalise
670 which will change a non-standard RAID6 layout into a more standard
671 arrangement.
672
673 .TP
674 .BR \-\-parity=
675 same as
676 .B \-\-layout
677 (thus explaining the p of
678 .BR \-p ).
679
680 .TP
681 .BR \-b ", " \-\-bitmap=
682 Specify a file to store a write-intent bitmap in. The file should not
683 exist unless
684 .B \-\-force
685 is also given. The same file should be provided
686 when assembling the array. If the word
687 .B "internal"
688 is given, then the bitmap is stored with the metadata on the array,
689 and so is replicated on all devices. If the word
690 .B "none"
691 is given with
692 .B \-\-grow
693 mode, then any bitmap that is present is removed.
694
695 To help catch typing errors, the filename must contain at least one
696 slash ('/') if it is a real file (not 'internal' or 'none').
697
698 Note: external bitmaps are only known to work on ext2 and ext3.
699 Storing bitmap files on other filesystems may result in serious problems.
700
701 .TP
702 .BR \-\-bitmap\-chunk=
703 Set the chunksize of the bitmap. Each bit corresponds to that many
704 Kilobytes of storage.
705 When using a file based bitmap, the default is to use the smallest
706 size that is at-least 4 and requires no more than 2^21 chunks.
707 When using an
708 .B internal
709 bitmap, the chunksize defaults to 64Meg, or larger if necessary to
710 fit the bitmap into the available space.
711
712 A suffix of 'M' or 'G' can be given to indicate Megabytes or
713 Gigabytes respectively.
714
715 .TP
716 .BR \-W ", " \-\-write\-mostly
717 subsequent devices listed in a
718 .BR \-\-build ,
719 .BR \-\-create ,
720 or
721 .B \-\-add
722 command will be flagged as 'write-mostly'. This is valid for RAID1
723 only and means that the 'md' driver will avoid reading from these
724 devices if at all possible. This can be useful if mirroring over a
725 slow link.
726
727 .TP
728 .BR \-\-write\-behind=
729 Specify that write-behind mode should be enabled (valid for RAID1
730 only). If an argument is specified, it will set the maximum number
731 of outstanding writes allowed. The default value is 256.
732 A write-intent bitmap is required in order to use write-behind
733 mode, and write-behind is only attempted on drives marked as
734 .IR write-mostly .
735
736 .TP
737 .BR \-\-assume\-clean
738 Tell
739 .I mdadm
740 that the array pre-existed and is known to be clean. It can be useful
741 when trying to recover from a major failure as you can be sure that no
742 data will be affected unless you actually write to the array. It can
743 also be used when creating a RAID1 or RAID10 if you want to avoid the
744 initial resync, however this practice \(em while normally safe \(em is not
745 recommended. Use this only if you really know what you are doing.
746 .IP
747 When the devices that will be part of a new array were filled
748 with zeros before creation the operator knows the array is
749 actually clean. If that is the case, such as after running
750 badblocks, this argument can be used to tell mdadm the
751 facts the operator knows.
752 .IP
753 When an array is resized to a larger size with
754 .B "\-\-grow \-\-size="
755 the new space is normally resynced in that same way that the whole
756 array is resynced at creation. From Linux version 3.0,
757 .B \-\-assume\-clean
758 can be used with that command to avoid the automatic resync.
759
760 .TP
761 .BR \-\-backup\-file=
762 This is needed when
763 .B \-\-grow
764 is used to increase the number of raid-devices in a RAID5 or RAID6 if
765 there are no spare devices available, or to shrink, change RAID level
766 or layout. See the GROW MODE section below on RAID\-DEVICES CHANGES.
767 The file must be stored on a separate device, not on the RAID array
768 being reshaped.
769
770 .TP
771 .BR \-\-continue
772 This option is complementary to the
773 .B \-\-freeze-reshape
774 option for assembly. It is needed when
775 .B \-\-grow
776 operation is interrupted and it is not restarted automatically due to
777 .B \-\-freeze-reshape
778 usage during array assembly. This option is used together with
779 .BR \-G
780 , (
781 .BR \-\-grow
782 ) command and device for a pending reshape to be continued.
783 All parameters required for reshape continuation will be read from array metadata.
784 If initial
785 .BR \-\-grow
786 command had required
787 .BR \-\-backup\-file=
788 option to be set, continuation option will require to have exactly the same
789 backup file given as well.
790 .IP
791 Any other parameter passed together with
792 .BR \-\-continue
793 option will be ignored.
794
795 .TP
796 .BR \-N ", " \-\-name=
797 Set a
798 .B name
799 for the array. This is currently only effective when creating an
800 array with a version-1 superblock, or an array in a DDF container.
801 The name is a simple textual string that can be used to identify array
802 components when assembling. If name is needed but not specified, it
803 is taken from the basename of the device that is being created.
804 e.g. when creating
805 .I /dev/md/home
806 the
807 .B name
808 will default to
809 .IR home .
810
811 .TP
812 .BR \-R ", " \-\-run
813 Insist that
814 .I mdadm
815 run the array, even if some of the components
816 appear to be active in another array or filesystem. Normally
817 .I mdadm
818 will ask for confirmation before including such components in an
819 array. This option causes that question to be suppressed.
820
821 .TP
822 .BR \-f ", " \-\-force
823 Insist that
824 .I mdadm
825 accept the geometry and layout specified without question. Normally
826 .I mdadm
827 will not allow creation of an array with only one device, and will try
828 to create a RAID5 array with one missing drive (as this makes the
829 initial resync work faster). With
830 .BR \-\-force ,
831 .I mdadm
832 will not try to be so clever.
833
834 .TP
835 .BR \-o ", " \-\-readonly
836 Start the array
837 .B read only
838 rather than read-write as normal. No writes will be allowed to the
839 array, and no resync, recovery, or reshape will be started.
840
841 .TP
842 .BR \-a ", " "\-\-auto{=yes,md,mdp,part,p}{NN}"
843 Instruct mdadm how to create the device file if needed, possibly allocating
844 an unused minor number. "md" causes a non-partitionable array
845 to be used (though since Linux 2.6.28, these array devices are in fact
846 partitionable). "mdp", "part" or "p" causes a partitionable array (2.6 and
847 later) to be used. "yes" requires the named md device to have
848 a 'standard' format, and the type and minor number will be determined
849 from this. With mdadm 3.0, device creation is normally left up to
850 .I udev
851 so this option is unlikely to be needed.
852 See DEVICE NAMES below.
853
854 The argument can also come immediately after
855 "\-a". e.g. "\-ap".
856
857 If
858 .B \-\-auto
859 is not given on the command line or in the config file, then
860 the default will be
861 .BR \-\-auto=yes .
862
863 If
864 .B \-\-scan
865 is also given, then any
866 .I auto=
867 entries in the config file will override the
868 .B \-\-auto
869 instruction given on the command line.
870
871 For partitionable arrays,
872 .I mdadm
873 will create the device file for the whole array and for the first 4
874 partitions. A different number of partitions can be specified at the
875 end of this option (e.g.
876 .BR \-\-auto=p7 ).
877 If the device name ends with a digit, the partition names add a 'p',
878 and a number, e.g.
879 .IR /dev/md/home1p3 .
880 If there is no trailing digit, then the partition names just have a
881 number added, e.g.
882 .IR /dev/md/scratch3 .
883
884 If the md device name is in a 'standard' format as described in DEVICE
885 NAMES, then it will be created, if necessary, with the appropriate
886 device number based on that name. If the device name is not in one of these
887 formats, then a unused device number will be allocated. The device
888 number will be considered unused if there is no active array for that
889 number, and there is no entry in /dev for that number and with a
890 non-standard name. Names that are not in 'standard' format are only
891 allowed in "/dev/md/".
892
893 This is meaningful with
894 .B \-\-create
895 or
896 .BR \-\-build .
897
898 .ig XX
899 .\".TP
900 .\".BR \-\-symlink = no
901 .\"Normally when
902 .\".B \-\-auto
903 .\"causes
904 .\".I mdadm
905 .\"to create devices in
906 .\".B /dev/md/
907 .\"it will also create symlinks from
908 .\".B /dev/
909 .\"with names starting with
910 .\".B md
911 .\"or
912 .\".BR md_ .
913 .\"Use
914 .\".B \-\-symlink=no
915 .\"to suppress this, or
916 .\".B \-\-symlink=yes
917 .\"to enforce this even if it is suppressing
918 .\".IR mdadm.conf .
919 .\"
920 .XX
921
922 .TP
923 .BR \-a ", " "\-\-add"
924 This option can be used in Grow mode in two cases.
925
926 If the target array is a Linear array, then
927 .B \-\-add
928 can be used to add one or more devices to the array. They
929 are simply catenated on to the end of the array. Once added, the
930 devices cannot be removed.
931
932 If the
933 .B \-\-raid\-disks
934 option is being used to increase the number of devices in an array,
935 then
936 .B \-\-add
937 can be used to add some extra devices to be included in the array.
938 In most cases this is not needed as the extra devices can be added as
939 spares first, and then the number of raid-disks can be changed.
940 However for RAID0, it is not possible to add spares. So to increase
941 the number of devices in a RAID0, it is necessary to set the new
942 number of devices, and to add the new devices, in the same command.
943
944 .SH For assemble:
945
946 .TP
947 .BR \-u ", " \-\-uuid=
948 uuid of array to assemble. Devices which don't have this uuid are
949 excluded
950
951 .TP
952 .BR \-m ", " \-\-super\-minor=
953 Minor number of device that array was created for. Devices which
954 don't have this minor number are excluded. If you create an array as
955 /dev/md1, then all superblocks will contain the minor number 1, even if
956 the array is later assembled as /dev/md2.
957
958 Giving the literal word "dev" for
959 .B \-\-super\-minor
960 will cause
961 .I mdadm
962 to use the minor number of the md device that is being assembled.
963 e.g. when assembling
964 .BR /dev/md0 ,
965 .B \-\-super\-minor=dev
966 will look for super blocks with a minor number of 0.
967
968 .B \-\-super\-minor
969 is only relevant for v0.90 metadata, and should not normally be used.
970 Using
971 .B \-\-uuid
972 is much safer.
973
974 .TP
975 .BR \-N ", " \-\-name=
976 Specify the name of the array to assemble. This must be the name
977 that was specified when creating the array. It must either match
978 the name stored in the superblock exactly, or it must match
979 with the current
980 .I homehost
981 prefixed to the start of the given name.
982
983 .TP
984 .BR \-f ", " \-\-force
985 Assemble the array even if the metadata on some devices appears to be
986 out-of-date. If
987 .I mdadm
988 cannot find enough working devices to start the array, but can find
989 some devices that are recorded as having failed, then it will mark
990 those devices as working so that the array can be started.
991 An array which requires
992 .B \-\-force
993 to be started may contain data corruption. Use it carefully.
994
995 .TP
996 .BR \-R ", " \-\-run
997 Attempt to start the array even if fewer drives were given than were
998 present last time the array was active. Normally if not all the
999 expected drives are found and
1000 .B \-\-scan
1001 is not used, then the array will be assembled but not started.
1002 With
1003 .B \-\-run
1004 an attempt will be made to start it anyway.
1005
1006 .TP
1007 .B \-\-no\-degraded
1008 This is the reverse of
1009 .B \-\-run
1010 in that it inhibits the startup of array unless all expected drives
1011 are present. This is only needed with
1012 .B \-\-scan,
1013 and can be used if the physical connections to devices are
1014 not as reliable as you would like.
1015
1016 .TP
1017 .BR \-a ", " "\-\-auto{=no,yes,md,mdp,part}"
1018 See this option under Create and Build options.
1019
1020 .TP
1021 .BR \-b ", " \-\-bitmap=
1022 Specify the bitmap file that was given when the array was created. If
1023 an array has an
1024 .B internal
1025 bitmap, there is no need to specify this when assembling the array.
1026
1027 .TP
1028 .BR \-\-backup\-file=
1029 If
1030 .B \-\-backup\-file
1031 was used while reshaping an array (e.g. changing number of devices or
1032 chunk size) and the system crashed during the critical section, then the same
1033 .B \-\-backup\-file
1034 must be presented to
1035 .B \-\-assemble
1036 to allow possibly corrupted data to be restored, and the reshape
1037 to be completed.
1038
1039 .TP
1040 .BR \-\-invalid\-backup
1041 If the file needed for the above option is not available for any
1042 reason an empty file can be given together with this option to
1043 indicate that the backup file is invalid. In this case the data that
1044 was being rearranged at the time of the crash could be irrecoverably
1045 lost, but the rest of the array may still be recoverable. This option
1046 should only be used as a last resort if there is no way to recover the
1047 backup file.
1048
1049
1050 .TP
1051 .BR \-U ", " \-\-update=
1052 Update the superblock on each device while assembling the array. The
1053 argument given to this flag can be one of
1054 .BR sparc2.2 ,
1055 .BR summaries ,
1056 .BR uuid ,
1057 .BR name ,
1058 .BR homehost ,
1059 .BR resync ,
1060 .BR byteorder ,
1061 .BR devicesize ,
1062 .BR no\-bitmap ,
1063 or
1064 .BR super\-minor .
1065
1066 The
1067 .B sparc2.2
1068 option will adjust the superblock of an array what was created on a Sparc
1069 machine running a patched 2.2 Linux kernel. This kernel got the
1070 alignment of part of the superblock wrong. You can use the
1071 .B "\-\-examine \-\-sparc2.2"
1072 option to
1073 .I mdadm
1074 to see what effect this would have.
1075
1076 The
1077 .B super\-minor
1078 option will update the
1079 .B "preferred minor"
1080 field on each superblock to match the minor number of the array being
1081 assembled.
1082 This can be useful if
1083 .B \-\-examine
1084 reports a different "Preferred Minor" to
1085 .BR \-\-detail .
1086 In some cases this update will be performed automatically
1087 by the kernel driver. In particular the update happens automatically
1088 at the first write to an array with redundancy (RAID level 1 or
1089 greater) on a 2.6 (or later) kernel.
1090
1091 The
1092 .B uuid
1093 option will change the uuid of the array. If a UUID is given with the
1094 .B \-\-uuid
1095 option that UUID will be used as a new UUID and will
1096 .B NOT
1097 be used to help identify the devices in the array.
1098 If no
1099 .B \-\-uuid
1100 is given, a random UUID is chosen.
1101
1102 The
1103 .B name
1104 option will change the
1105 .I name
1106 of the array as stored in the superblock. This is only supported for
1107 version-1 superblocks.
1108
1109 The
1110 .B homehost
1111 option will change the
1112 .I homehost
1113 as recorded in the superblock. For version-0 superblocks, this is the
1114 same as updating the UUID.
1115 For version-1 superblocks, this involves updating the name.
1116
1117 The
1118 .B resync
1119 option will cause the array to be marked
1120 .I dirty
1121 meaning that any redundancy in the array (e.g. parity for RAID5,
1122 copies for RAID1) may be incorrect. This will cause the RAID system
1123 to perform a "resync" pass to make sure that all redundant information
1124 is correct.
1125
1126 The
1127 .B byteorder
1128 option allows arrays to be moved between machines with different
1129 byte-order.
1130 When assembling such an array for the first time after a move, giving
1131 .B "\-\-update=byteorder"
1132 will cause
1133 .I mdadm
1134 to expect superblocks to have their byteorder reversed, and will
1135 correct that order before assembling the array. This is only valid
1136 with original (Version 0.90) superblocks.
1137
1138 The
1139 .B summaries
1140 option will correct the summaries in the superblock. That is the
1141 counts of total, working, active, failed, and spare devices.
1142
1143 The
1144 .B devicesize
1145 option will rarely be of use. It applies to version 1.1 and 1.2 metadata
1146 only (where the metadata is at the start of the device) and is only
1147 useful when the component device has changed size (typically become
1148 larger). The version 1 metadata records the amount of the device that
1149 can be used to store data, so if a device in a version 1.1 or 1.2
1150 array becomes larger, the metadata will still be visible, but the
1151 extra space will not. In this case it might be useful to assemble the
1152 array with
1153 .BR \-\-update=devicesize .
1154 This will cause
1155 .I mdadm
1156 to determine the maximum usable amount of space on each device and
1157 update the relevant field in the metadata.
1158
1159 The
1160 .B no\-bitmap
1161 option can be used when an array has an internal bitmap which is
1162 corrupt in some way so that assembling the array normally fails. It
1163 will cause any internal bitmap to be ignored.
1164
1165 .TP
1166 .BR \-\-freeze\-reshape
1167 Option is intended to be used in start-up scripts during initrd boot phase.
1168 When array under reshape is assembled during initrd phase, this option
1169 stops reshape after reshape critical section is being restored. This happens
1170 before file system pivot operation and avoids loss of file system context.
1171 Losing file system context would cause reshape to be broken.
1172
1173 Reshape can be continued later using the
1174 .B \-\-continue
1175 option for the grow command.
1176
1177 .SH For Manage mode:
1178
1179 .TP
1180 .BR \-t ", " \-\-test
1181 Unless a more serious error occurred,
1182 .I mdadm
1183 will exit with a status of 2 if no changes were made to the array and
1184 0 if at least one change was made.
1185 This can be useful when an indirect specifier such as
1186 .BR missing ,
1187 .B detached
1188 or
1189 .B faulty
1190 is used in requesting an operation on the array.
1191 .B \-\-test
1192 will report failure if these specifiers didn't find any match.
1193
1194 .TP
1195 .BR \-a ", " \-\-add
1196 hot-add listed devices.
1197 If a device appears to have recently been part of the array
1198 (possibly it failed or was removed) the device is re\-added as described
1199 in the next point.
1200 If that fails or the device was never part of the array, the device is
1201 added as a hot-spare.
1202 If the array is degraded, it will immediately start to rebuild data
1203 onto that spare.
1204
1205 Note that this and the following options are only meaningful on array
1206 with redundancy. They don't apply to RAID0 or Linear.
1207
1208 .TP
1209 .BR \-\-re\-add
1210 re\-add a device that was previous removed from an array.
1211 If the metadata on the device reports that it is a member of the
1212 array, and the slot that it used is still vacant, then the device will
1213 be added back to the array in the same position. This will normally
1214 cause the data for that device to be recovered. However based on the
1215 event count on the device, the recovery may only require sections that
1216 are flagged a write-intent bitmap to be recovered or may not require
1217 any recovery at all.
1218
1219 When used on an array that has no metadata (i.e. it was built with
1220 .BR \-\-build)
1221 it will be assumed that bitmap-based recovery is enough to make the
1222 device fully consistent with the array.
1223
1224 When
1225 .B \-\-re\-add
1226 can be accompanied by
1227 .BR \-\-update=devicesize .
1228 See the description of this option when used in Assemble mode for an
1229 explanation of its use.
1230
1231 If the device name given is
1232 .B missing
1233 then mdadm will try to find any device that looks like it should be
1234 part of the array but isn't and will try to re\-add all such devices.
1235
1236 .TP
1237 .BR \-r ", " \-\-remove
1238 remove listed devices. They must not be active. i.e. they should
1239 be failed or spare devices. As well as the name of a device file
1240 (e.g.
1241 .BR /dev/sda1 )
1242 the words
1243 .B failed
1244 and
1245 .B detached
1246 can be given to
1247 .BR \-\-remove .
1248 The first causes all failed device to be removed. The second causes
1249 any device which is no longer connected to the system (i.e an 'open'
1250 returns
1251 .BR ENXIO )
1252 to be removed. This will only succeed for devices that are spares or
1253 have already been marked as failed.
1254
1255 .TP
1256 .BR \-f ", " \-\-fail
1257 mark listed devices as faulty.
1258 As well as the name of a device file, the word
1259 .B detached
1260 can be given. This will cause any device that has been detached from
1261 the system to be marked as failed. It can then be removed.
1262
1263 .TP
1264 .BR \-\-set\-faulty
1265 same as
1266 .BR \-\-fail .
1267
1268 .TP
1269 .BR \-\-write\-mostly
1270 Subsequent devices that are added or re\-added will have the 'write-mostly'
1271 flag set. This is only valid for RAID1 and means that the 'md' driver
1272 will avoid reading from these devices if possible.
1273 .TP
1274 .BR \-\-readwrite
1275 Subsequent devices that are added or re\-added will have the 'write-mostly'
1276 flag cleared.
1277
1278 .P
1279 Each of these options requires that the first device listed is the array
1280 to be acted upon, and the remainder are component devices to be added,
1281 removed, marked as faulty, etc. Several different operations can be
1282 specified for different devices, e.g.
1283 .in +5
1284 mdadm /dev/md0 \-\-add /dev/sda1 \-\-fail /dev/sdb1 \-\-remove /dev/sdb1
1285 .in -5
1286 Each operation applies to all devices listed until the next
1287 operation.
1288
1289 If an array is using a write-intent bitmap, then devices which have
1290 been removed can be re\-added in a way that avoids a full
1291 reconstruction but instead just updates the blocks that have changed
1292 since the device was removed. For arrays with persistent metadata
1293 (superblocks) this is done automatically. For arrays created with
1294 .B \-\-build
1295 mdadm needs to be told that this device we removed recently with
1296 .BR \-\-re\-add .
1297
1298 Devices can only be removed from an array if they are not in active
1299 use, i.e. that must be spares or failed devices. To remove an active
1300 device, it must first be marked as
1301 .B faulty.
1302
1303 .SH For Misc mode:
1304
1305 .TP
1306 .BR \-Q ", " \-\-query
1307 Examine a device to see
1308 (1) if it is an md device and (2) if it is a component of an md
1309 array.
1310 Information about what is discovered is presented.
1311
1312 .TP
1313 .BR \-D ", " \-\-detail
1314 Print details of one or more md devices.
1315
1316 .TP
1317 .BR \-\-detail\-platform
1318 Print details of the platform's RAID capabilities (firmware / hardware
1319 topology) for a given metadata format.
1320
1321 .TP
1322 .BR \-Y ", " \-\-export
1323 When used with
1324 .B \-\-detail , \-\-detail-platform
1325 or
1326 .BR \-\-examine ,
1327 output will be formatted as
1328 .B key=value
1329 pairs for easy import into the environment.
1330
1331 .TP
1332 .BR \-E ", " \-\-examine
1333 Print contents of the metadata stored on the named device(s).
1334 Note the contrast between
1335 .B \-\-examine
1336 and
1337 .BR \-\-detail .
1338 .B \-\-examine
1339 applies to devices which are components of an array, while
1340 .B \-\-detail
1341 applies to a whole array which is currently active.
1342 .TP
1343 .B \-\-sparc2.2
1344 If an array was created on a SPARC machine with a 2.2 Linux kernel
1345 patched with RAID support, the superblock will have been created
1346 incorrectly, or at least incompatibly with 2.4 and later kernels.
1347 Using the
1348 .B \-\-sparc2.2
1349 flag with
1350 .B \-\-examine
1351 will fix the superblock before displaying it. If this appears to do
1352 the right thing, then the array can be successfully assembled using
1353 .BR "\-\-assemble \-\-update=sparc2.2" .
1354
1355 .TP
1356 .BR \-X ", " \-\-examine\-bitmap
1357 Report information about a bitmap file.
1358 The argument is either an external bitmap file or an array component
1359 in case of an internal bitmap. Note that running this on an array
1360 device (e.g.
1361 .BR /dev/md0 )
1362 does not report the bitmap for that array.
1363
1364 .TP
1365 .BR \-R ", " \-\-run
1366 start a partially assembled array. If
1367 .B \-\-assemble
1368 did not find enough devices to fully start the array, it might leaving
1369 it partially assembled. If you wish, you can then use
1370 .B \-\-run
1371 to start the array in degraded mode.
1372
1373 .TP
1374 .BR \-S ", " \-\-stop
1375 deactivate array, releasing all resources.
1376
1377 .TP
1378 .BR \-o ", " \-\-readonly
1379 mark array as readonly.
1380
1381 .TP
1382 .BR \-w ", " \-\-readwrite
1383 mark array as readwrite.
1384
1385 .TP
1386 .B \-\-zero\-superblock
1387 If the device contains a valid md superblock, the block is
1388 overwritten with zeros. With
1389 .B \-\-force
1390 the block where the superblock would be is overwritten even if it
1391 doesn't appear to be valid.
1392
1393 .TP
1394 .B \-\-kill\-subarray=
1395 If the device is a container and the argument to \-\-kill\-subarray
1396 specifies an inactive subarray in the container, then the subarray is
1397 deleted. Deleting all subarrays will leave an 'empty-container' or
1398 spare superblock on the drives. See \-\-zero\-superblock for completely
1399 removing a superblock. Note that some formats depend on the subarray
1400 index for generating a UUID, this command will fail if it would change
1401 the UUID of an active subarray.
1402
1403 .TP
1404 .B \-\-update\-subarray=
1405 If the device is a container and the argument to \-\-update\-subarray
1406 specifies a subarray in the container, then attempt to update the given
1407 superblock field in the subarray. See below in
1408 .B MISC MODE
1409 for details.
1410
1411 .TP
1412 .BR \-t ", " \-\-test
1413 When used with
1414 .BR \-\-detail ,
1415 the exit status of
1416 .I mdadm
1417 is set to reflect the status of the device. See below in
1418 .B MISC MODE
1419 for details.
1420
1421 .TP
1422 .BR \-W ", " \-\-wait
1423 For each md device given, wait for any resync, recovery, or reshape
1424 activity to finish before returning.
1425 .I mdadm
1426 will return with success if it actually waited for every device
1427 listed, otherwise it will return failure.
1428
1429 .TP
1430 .BR \-\-wait\-clean
1431 For each md device given, or each device in /proc/mdstat if
1432 .B \-\-scan
1433 is given, arrange for the array to be marked clean as soon as possible.
1434 .I mdadm
1435 will return with success if the array uses external metadata and we
1436 successfully waited. For native arrays this returns immediately as the
1437 kernel handles dirty-clean transitions at shutdown. No action is taken
1438 if safe-mode handling is disabled.
1439
1440 .SH For Incremental Assembly mode:
1441 .TP
1442 .BR \-\-rebuild\-map ", " \-r
1443 Rebuild the map file
1444 .RB ( {MAP_PATH} )
1445 that
1446 .I mdadm
1447 uses to help track which arrays are currently being assembled.
1448
1449 .TP
1450 .BR \-\-run ", " \-R
1451 Run any array assembled as soon as a minimal number of devices are
1452 available, rather than waiting until all expected devices are present.
1453
1454 .TP
1455 .BR \-\-scan ", " \-s
1456 Only meaningful with
1457 .B \-R
1458 this will scan the
1459 .B map
1460 file for arrays that are being incrementally assembled and will try to
1461 start any that are not already started. If any such array is listed
1462 in
1463 .B mdadm.conf
1464 as requiring an external bitmap, that bitmap will be attached first.
1465
1466 .TP
1467 .BR \-\-fail ", " \-f
1468 This allows the hot-plug system to remove devices that have fully disappeared
1469 from the kernel. It will first fail and then remove the device from any
1470 array it belongs to.
1471 The device name given should be a kernel device name such as "sda",
1472 not a name in
1473 .IR /dev .
1474
1475 .TP
1476 .BR \-\-path=
1477 Only used with \-\-fail. The 'path' given will be recorded so that if
1478 a new device appears at the same location it can be automatically
1479 added to the same array. This allows the failed device to be
1480 automatically replaced by a new device without metadata if it appears
1481 at specified path. This option is normally only set by a
1482 .I udev
1483 script.
1484
1485 .SH For Monitor mode:
1486 .TP
1487 .BR \-m ", " \-\-mail
1488 Give a mail address to send alerts to.
1489
1490 .TP
1491 .BR \-p ", " \-\-program ", " \-\-alert
1492 Give a program to be run whenever an event is detected.
1493
1494 .TP
1495 .BR \-y ", " \-\-syslog
1496 Cause all events to be reported through 'syslog'. The messages have
1497 facility of 'daemon' and varying priorities.
1498
1499 .TP
1500 .BR \-d ", " \-\-delay
1501 Give a delay in seconds.
1502 .I mdadm
1503 polls the md arrays and then waits this many seconds before polling
1504 again. The default is 60 seconds. Since 2.6.16, there is no need to
1505 reduce this as the kernel alerts
1506 .I mdadm
1507 immediately when there is any change.
1508
1509 .TP
1510 .BR \-r ", " \-\-increment
1511 Give a percentage increment.
1512 .I mdadm
1513 will generate RebuildNN events with the given percentage increment.
1514
1515 .TP
1516 .BR \-f ", " \-\-daemonise
1517 Tell
1518 .I mdadm
1519 to run as a background daemon if it decides to monitor anything. This
1520 causes it to fork and run in the child, and to disconnect from the
1521 terminal. The process id of the child is written to stdout.
1522 This is useful with
1523 .B \-\-scan
1524 which will only continue monitoring if a mail address or alert program
1525 is found in the config file.
1526
1527 .TP
1528 .BR \-i ", " \-\-pid\-file
1529 When
1530 .I mdadm
1531 is running in daemon mode, write the pid of the daemon process to
1532 the specified file, instead of printing it on standard output.
1533
1534 .TP
1535 .BR \-1 ", " \-\-oneshot
1536 Check arrays only once. This will generate
1537 .B NewArray
1538 events and more significantly
1539 .B DegradedArray
1540 and
1541 .B SparesMissing
1542 events. Running
1543 .in +5
1544 .B " mdadm \-\-monitor \-\-scan \-1"
1545 .in -5
1546 from a cron script will ensure regular notification of any degraded arrays.
1547
1548 .TP
1549 .BR \-t ", " \-\-test
1550 Generate a
1551 .B TestMessage
1552 alert for every array found at startup. This alert gets mailed and
1553 passed to the alert program. This can be used for testing that alert
1554 message do get through successfully.
1555
1556 .TP
1557 .BR \-\-no\-sharing
1558 This inhibits the functionality for moving spares between arrays.
1559 Only one monitoring process started with
1560 .B \-\-scan
1561 but without this flag is allowed, otherwise the two could interfere
1562 with each other.
1563
1564 .SH ASSEMBLE MODE
1565
1566 .HP 12
1567 Usage:
1568 .B mdadm \-\-assemble
1569 .I md-device options-and-component-devices...
1570 .HP 12
1571 Usage:
1572 .B mdadm \-\-assemble \-\-scan
1573 .I md-devices-and-options...
1574 .HP 12
1575 Usage:
1576 .B mdadm \-\-assemble \-\-scan
1577 .I options...
1578
1579 .PP
1580 This usage assembles one or more RAID arrays from pre-existing components.
1581 For each array, mdadm needs to know the md device, the identity of the
1582 array, and a number of component-devices. These can be found in a number of ways.
1583
1584 In the first usage example (without the
1585 .BR \-\-scan )
1586 the first device given is the md device.
1587 In the second usage example, all devices listed are treated as md
1588 devices and assembly is attempted.
1589 In the third (where no devices are listed) all md devices that are
1590 listed in the configuration file are assembled. If no arrays are
1591 described by the configuration file, then any arrays that
1592 can be found on unused devices will be assembled.
1593
1594 If precisely one device is listed, but
1595 .B \-\-scan
1596 is not given, then
1597 .I mdadm
1598 acts as though
1599 .B \-\-scan
1600 was given and identity information is extracted from the configuration file.
1601
1602 The identity can be given with the
1603 .B \-\-uuid
1604 option, the
1605 .B \-\-name
1606 option, or the
1607 .B \-\-super\-minor
1608 option, will be taken from the md-device record in the config file, or
1609 will be taken from the super block of the first component-device
1610 listed on the command line.
1611
1612 Devices can be given on the
1613 .B \-\-assemble
1614 command line or in the config file. Only devices which have an md
1615 superblock which contains the right identity will be considered for
1616 any array.
1617
1618 The config file is only used if explicitly named with
1619 .B \-\-config
1620 or requested with (a possibly implicit)
1621 .BR \-\-scan .
1622 In the later case,
1623 .B /etc/mdadm.conf
1624 or
1625 .B /etc/mdadm/mdadm.conf
1626 is used.
1627
1628 If
1629 .B \-\-scan
1630 is not given, then the config file will only be used to find the
1631 identity of md arrays.
1632
1633 Normally the array will be started after it is assembled. However if
1634 .B \-\-scan
1635 is not given and not all expected drives were listed, then the array
1636 is not started (to guard against usage errors). To insist that the
1637 array be started in this case (as may work for RAID1, 4, 5, 6, or 10),
1638 give the
1639 .B \-\-run
1640 flag.
1641
1642 If
1643 .I udev
1644 is active,
1645 .I mdadm
1646 does not create any entries in
1647 .B /dev
1648 but leaves that to
1649 .IR udev .
1650 It does record information in
1651 .B {MAP_PATH}
1652 which will allow
1653 .I udev
1654 to choose the correct name.
1655
1656 If
1657 .I mdadm
1658 detects that udev is not configured, it will create the devices in
1659 .B /dev
1660 itself.
1661
1662 In Linux kernels prior to version 2.6.28 there were two distinctly
1663 different types of md devices that could be created: one that could be
1664 partitioned using standard partitioning tools and one that could not.
1665 Since 2.6.28 that distinction is no longer relevant as both type of
1666 devices can be partitioned.
1667 .I mdadm
1668 will normally create the type that originally could not be partitioned
1669 as it has a well defined major number (9).
1670
1671 Prior to 2.6.28, it is important that mdadm chooses the correct type
1672 of array device to use. This can be controlled with the
1673 .B \-\-auto
1674 option. In particular, a value of "mdp" or "part" or "p" tells mdadm
1675 to use a partitionable device rather than the default.
1676
1677 In the no-udev case, the value given to
1678 .B \-\-auto
1679 can be suffixed by a number. This tells
1680 .I mdadm
1681 to create that number of partition devices rather than the default of 4.
1682
1683 The value given to
1684 .B \-\-auto
1685 can also be given in the configuration file as a word starting
1686 .B auto=
1687 on the ARRAY line for the relevant array.
1688
1689 .SS Auto Assembly
1690 When
1691 .B \-\-assemble
1692 is used with
1693 .B \-\-scan
1694 and no devices are listed,
1695 .I mdadm
1696 will first attempt to assemble all the arrays listed in the config
1697 file.
1698
1699 If no arrays are listed in the config (other than those marked
1700 .BR <ignore> )
1701 it will look through the available devices for possible arrays and
1702 will try to assemble anything that it finds. Arrays which are tagged
1703 as belonging to the given homehost will be assembled and started
1704 normally. Arrays which do not obviously belong to this host are given
1705 names that are expected not to conflict with anything local, and are
1706 started "read-auto" so that nothing is written to any device until the
1707 array is written to. i.e. automatic resync etc is delayed.
1708
1709 If
1710 .I mdadm
1711 finds a consistent set of devices that look like they should comprise
1712 an array, and if the superblock is tagged as belonging to the given
1713 home host, it will automatically choose a device name and try to
1714 assemble the array. If the array uses version-0.90 metadata, then the
1715 .B minor
1716 number as recorded in the superblock is used to create a name in
1717 .B /dev/md/
1718 so for example
1719 .BR /dev/md/3 .
1720 If the array uses version-1 metadata, then the
1721 .B name
1722 from the superblock is used to similarly create a name in
1723 .B /dev/md/
1724 (the name will have any 'host' prefix stripped first).
1725
1726 This behaviour can be modified by the
1727 .I AUTO
1728 line in the
1729 .I mdadm.conf
1730 configuration file. This line can indicate that specific metadata
1731 type should, or should not, be automatically assembled. If an array
1732 is found which is not listed in
1733 .I mdadm.conf
1734 and has a metadata format that is denied by the
1735 .I AUTO
1736 line, then it will not be assembled.
1737 The
1738 .I AUTO
1739 line can also request that all arrays identified as being for this
1740 homehost should be assembled regardless of their metadata type.
1741 See
1742 .IR mdadm.conf (5)
1743 for further details.
1744
1745 Note: Auto assembly cannot be used for assembling and activating some
1746 arrays which are undergoing reshape. In particular as the
1747 .B backup\-file
1748 cannot be given, any reshape which requires a backup-file to continue
1749 cannot be started by auto assembly. An array which is growing to more
1750 devices and has passed the critical section can be assembled using
1751 auto-assembly.
1752
1753 .SH BUILD MODE
1754
1755 .HP 12
1756 Usage:
1757 .B mdadm \-\-build
1758 .I md-device
1759 .BI \-\-chunk= X
1760 .BI \-\-level= Y
1761 .BI \-\-raid\-devices= Z
1762 .I devices
1763
1764 .PP
1765 This usage is similar to
1766 .BR \-\-create .
1767 The difference is that it creates an array without a superblock. With
1768 these arrays there is no difference between initially creating the array and
1769 subsequently assembling the array, except that hopefully there is useful
1770 data there in the second case.
1771
1772 The level may raid0, linear, raid1, raid10, multipath, or faulty, or
1773 one of their synonyms. All devices must be listed and the array will
1774 be started once complete. It will often be appropriate to use
1775 .B \-\-assume\-clean
1776 with levels raid1 or raid10.
1777
1778 .SH CREATE MODE
1779
1780 .HP 12
1781 Usage:
1782 .B mdadm \-\-create
1783 .I md-device
1784 .BI \-\-chunk= X
1785 .BI \-\-level= Y
1786 .br
1787 .BI \-\-raid\-devices= Z
1788 .I devices
1789
1790 .PP
1791 This usage will initialise a new md array, associate some devices with
1792 it, and activate the array.
1793
1794 The named device will normally not exist when
1795 .I "mdadm \-\-create"
1796 is run, but will be created by
1797 .I udev
1798 once the array becomes active.
1799
1800 As devices are added, they are checked to see if they contain RAID
1801 superblocks or filesystems. They are also checked to see if the variance in
1802 device size exceeds 1%.
1803
1804 If any discrepancy is found, the array will not automatically be run, though
1805 the presence of a
1806 .B \-\-run
1807 can override this caution.
1808
1809 To create a "degraded" array in which some devices are missing, simply
1810 give the word "\fBmissing\fP"
1811 in place of a device name. This will cause
1812 .I mdadm
1813 to leave the corresponding slot in the array empty.
1814 For a RAID4 or RAID5 array at most one slot can be
1815 "\fBmissing\fP"; for a RAID6 array at most two slots.
1816 For a RAID1 array, only one real device needs to be given. All of the
1817 others can be
1818 "\fBmissing\fP".
1819
1820 When creating a RAID5 array,
1821 .I mdadm
1822 will automatically create a degraded array with an extra spare drive.
1823 This is because building the spare into a degraded array is in general
1824 faster than resyncing the parity on a non-degraded, but not clean,
1825 array. This feature can be overridden with the
1826 .B \-\-force
1827 option.
1828
1829 When creating an array with version-1 metadata a name for the array is
1830 required.
1831 If this is not given with the
1832 .B \-\-name
1833 option,
1834 .I mdadm
1835 will choose a name based on the last component of the name of the
1836 device being created. So if
1837 .B /dev/md3
1838 is being created, then the name
1839 .B 3
1840 will be chosen.
1841 If
1842 .B /dev/md/home
1843 is being created, then the name
1844 .B home
1845 will be used.
1846
1847 When creating a partition based array, using
1848 .I mdadm
1849 with version-1.x metadata, the partition type should be set to
1850 .B 0xDA
1851 (non fs-data). This type selection allows for greater precision since
1852 using any other [RAID auto-detect (0xFD) or a GNU/Linux partition (0x83)],
1853 might create problems in the event of array recovery through a live cdrom.
1854
1855 A new array will normally get a randomly assigned 128bit UUID which is
1856 very likely to be unique. If you have a specific need, you can choose
1857 a UUID for the array by giving the
1858 .B \-\-uuid=
1859 option. Be warned that creating two arrays with the same UUID is a
1860 recipe for disaster. Also, using
1861 .B \-\-uuid=
1862 when creating a v0.90 array will silently override any
1863 .B \-\-homehost=
1864 setting.
1865 .\"If the
1866 .\".B \-\-size
1867 .\"option is given, it is not necessary to list any component-devices in this command.
1868 .\"They can be added later, before a
1869 .\".B \-\-run.
1870 .\"If no
1871 .\".B \-\-size
1872 .\"is given, the apparent size of the smallest drive given is used.
1873
1874 If the metadata type supports it (currently only 1.x metadata), space
1875 will be allocated to store a bad block list. This allows a modest
1876 number of bad blocks to be recorded, allowing the drive to remain in
1877 service while only partially functional.
1878
1879 When creating an array within a
1880 .B CONTAINER
1881 .I mdadm
1882 can be given either the list of devices to use, or simply the name of
1883 the container. The former case gives control over which devices in
1884 the container will be used for the array. The latter case allows
1885 .I mdadm
1886 to automatically choose which devices to use based on how much spare
1887 space is available.
1888
1889 The General Management options that are valid with
1890 .B \-\-create
1891 are:
1892 .TP
1893 .B \-\-run
1894 insist on running the array even if some devices look like they might
1895 be in use.
1896
1897 .TP
1898 .B \-\-readonly
1899 start the array readonly \(em not supported yet.
1900
1901 .SH MANAGE MODE
1902 .HP 12
1903 Usage:
1904 .B mdadm
1905 .I device
1906 .I options... devices...
1907 .PP
1908
1909 This usage will allow individual devices in an array to be failed,
1910 removed or added. It is possible to perform multiple operations with
1911 on command. For example:
1912 .br
1913 .B " mdadm /dev/md0 \-f /dev/hda1 \-r /dev/hda1 \-a /dev/hda1"
1914 .br
1915 will firstly mark
1916 .B /dev/hda1
1917 as faulty in
1918 .B /dev/md0
1919 and will then remove it from the array and finally add it back
1920 in as a spare. However only one md array can be affected by a single
1921 command.
1922
1923 When a device is added to an active array, mdadm checks to see if it
1924 has metadata on it which suggests that it was recently a member of the
1925 array. If it does, it tries to "re\-add" the device. If there have
1926 been no changes since the device was removed, or if the array has a
1927 write-intent bitmap which has recorded whatever changes there were,
1928 then the device will immediately become a full member of the array and
1929 those differences recorded in the bitmap will be resolved.
1930
1931 .SH MISC MODE
1932 .HP 12
1933 Usage:
1934 .B mdadm
1935 .I options ...
1936 .I devices ...
1937 .PP
1938
1939 MISC mode includes a number of distinct operations that
1940 operate on distinct devices. The operations are:
1941 .TP
1942 .B \-\-query
1943 The device is examined to see if it is
1944 (1) an active md array, or
1945 (2) a component of an md array.
1946 The information discovered is reported.
1947
1948 .TP
1949 .B \-\-detail
1950 The device should be an active md device.
1951 .B mdadm
1952 will display a detailed description of the array.
1953 .B \-\-brief
1954 or
1955 .B \-\-scan
1956 will cause the output to be less detailed and the format to be
1957 suitable for inclusion in
1958 .BR mdadm.conf .
1959 The exit status of
1960 .I mdadm
1961 will normally be 0 unless
1962 .I mdadm
1963 failed to get useful information about the device(s); however, if the
1964 .B \-\-test
1965 option is given, then the exit status will be:
1966 .RS
1967 .TP
1968 0
1969 The array is functioning normally.
1970 .TP
1971 1
1972 The array has at least one failed device.
1973 .TP
1974 2
1975 The array has multiple failed devices such that it is unusable.
1976 .TP
1977 4
1978 There was an error while trying to get information about the device.
1979 .RE
1980
1981 .TP
1982 .B \-\-detail\-platform
1983 Print detail of the platform's RAID capabilities (firmware / hardware
1984 topology). If the metadata is specified with
1985 .B \-e
1986 or
1987 .B \-\-metadata=
1988 then the return status will be:
1989 .RS
1990 .TP
1991 0
1992 metadata successfully enumerated its platform components on this system
1993 .TP
1994 1
1995 metadata is platform independent
1996 .TP
1997 2
1998 metadata failed to find its platform components on this system
1999 .RE
2000
2001 .TP
2002 .B \-\-update\-subarray=
2003 If the device is a container and the argument to \-\-update\-subarray
2004 specifies a subarray in the container, then attempt to update the given
2005 superblock field in the subarray. Similar to updating an array in
2006 "assemble" mode, the field to update is selected by
2007 .B \-U
2008 or
2009 .B \-\-update=
2010 option. Currently only
2011 .B name
2012 is supported.
2013
2014 The
2015 .B name
2016 option updates the subarray name in the metadata, it may not affect the
2017 device node name or the device node symlink until the subarray is
2018 re\-assembled. If updating
2019 .B name
2020 would change the UUID of an active subarray this operation is blocked,
2021 and the command will end in an error.
2022
2023 .TP
2024 .B \-\-examine
2025 The device should be a component of an md array.
2026 .I mdadm
2027 will read the md superblock of the device and display the contents.
2028 If
2029 .B \-\-brief
2030 or
2031 .B \-\-scan
2032 is given, then multiple devices that are components of the one array
2033 are grouped together and reported in a single entry suitable
2034 for inclusion in
2035 .BR mdadm.conf .
2036
2037 Having
2038 .B \-\-scan
2039 without listing any devices will cause all devices listed in the
2040 config file to be examined.
2041
2042 .TP
2043 .B \-\-stop
2044 The devices should be active md arrays which will be deactivated, as
2045 long as they are not currently in use.
2046
2047 .TP
2048 .B \-\-run
2049 This will fully activate a partially assembled md array.
2050
2051 .TP
2052 .B \-\-readonly
2053 This will mark an active array as read-only, providing that it is
2054 not currently being used.
2055
2056 .TP
2057 .B \-\-readwrite
2058 This will change a
2059 .B readonly
2060 array back to being read/write.
2061
2062 .TP
2063 .B \-\-scan
2064 For all operations except
2065 .BR \-\-examine ,
2066 .B \-\-scan
2067 will cause the operation to be applied to all arrays listed in
2068 .BR /proc/mdstat .
2069 For
2070 .BR \-\-examine,
2071 .B \-\-scan
2072 causes all devices listed in the config file to be examined.
2073
2074 .TP
2075 .BR \-b ", " \-\-brief
2076 Be less verbose. This is used with
2077 .B \-\-detail
2078 and
2079 .BR \-\-examine .
2080 Using
2081 .B \-\-brief
2082 with
2083 .B \-\-verbose
2084 gives an intermediate level of verbosity.
2085
2086 .SH MONITOR MODE
2087
2088 .HP 12
2089 Usage:
2090 .B mdadm \-\-monitor
2091 .I options... devices...
2092
2093 .PP
2094 This usage causes
2095 .I mdadm
2096 to periodically poll a number of md arrays and to report on any events
2097 noticed.
2098 .I mdadm
2099 will never exit once it decides that there are arrays to be checked,
2100 so it should normally be run in the background.
2101
2102 As well as reporting events,
2103 .I mdadm
2104 may move a spare drive from one array to another if they are in the
2105 same
2106 .B spare-group
2107 or
2108 .B domain
2109 and if the destination array has a failed drive but no spares.
2110
2111 If any devices are listed on the command line,
2112 .I mdadm
2113 will only monitor those devices. Otherwise all arrays listed in the
2114 configuration file will be monitored. Further, if
2115 .B \-\-scan
2116 is given, then any other md devices that appear in
2117 .B /proc/mdstat
2118 will also be monitored.
2119
2120 The result of monitoring the arrays is the generation of events.
2121 These events are passed to a separate program (if specified) and may
2122 be mailed to a given E-mail address.
2123
2124 When passing events to a program, the program is run once for each event,
2125 and is given 2 or 3 command-line arguments: the first is the
2126 name of the event (see below), the second is the name of the
2127 md device which is affected, and the third is the name of a related
2128 device if relevant (such as a component device that has failed).
2129
2130 If
2131 .B \-\-scan
2132 is given, then a program or an E-mail address must be specified on the
2133 command line or in the config file. If neither are available, then
2134 .I mdadm
2135 will not monitor anything.
2136 Without
2137 .B \-\-scan,
2138 .I mdadm
2139 will continue monitoring as long as something was found to monitor. If
2140 no program or email is given, then each event is reported to
2141 .BR stdout .
2142
2143 The different events are:
2144
2145 .RS 4
2146 .TP
2147 .B DeviceDisappeared
2148 An md array which previously was configured appears to no longer be
2149 configured. (syslog priority: Critical)
2150
2151 If
2152 .I mdadm
2153 was told to monitor an array which is RAID0 or Linear, then it will
2154 report
2155 .B DeviceDisappeared
2156 with the extra information
2157 .BR Wrong-Level .
2158 This is because RAID0 and Linear do not support the device-failed,
2159 hot-spare and resync operations which are monitored.
2160
2161 .TP
2162 .B RebuildStarted
2163 An md array started reconstruction. (syslog priority: Warning)
2164
2165 .TP
2166 .BI Rebuild NN
2167 Where
2168 .I NN
2169 is a two-digit number (ie. 05, 48). This indicates that rebuild
2170 has passed that many percent of the total. The events are generated
2171 with fixed increment since 0. Increment size may be specified with
2172 a commandline option (default is 20). (syslog priority: Warning)
2173
2174 .TP
2175 .B RebuildFinished
2176 An md array that was rebuilding, isn't any more, either because it
2177 finished normally or was aborted. (syslog priority: Warning)
2178
2179 .TP
2180 .B Fail
2181 An active component device of an array has been marked as
2182 faulty. (syslog priority: Critical)
2183
2184 .TP
2185 .B FailSpare
2186 A spare component device which was being rebuilt to replace a faulty
2187 device has failed. (syslog priority: Critical)
2188
2189 .TP
2190 .B SpareActive
2191 A spare component device which was being rebuilt to replace a faulty
2192 device has been successfully rebuilt and has been made active.
2193 (syslog priority: Info)
2194
2195 .TP
2196 .B NewArray
2197 A new md array has been detected in the
2198 .B /proc/mdstat
2199 file. (syslog priority: Info)
2200
2201 .TP
2202 .B DegradedArray
2203 A newly noticed array appears to be degraded. This message is not
2204 generated when
2205 .I mdadm
2206 notices a drive failure which causes degradation, but only when
2207 .I mdadm
2208 notices that an array is degraded when it first sees the array.
2209 (syslog priority: Critical)
2210
2211 .TP
2212 .B MoveSpare
2213 A spare drive has been moved from one array in a
2214 .B spare-group
2215 or
2216 .B domain
2217 to another to allow a failed drive to be replaced.
2218 (syslog priority: Info)
2219
2220 .TP
2221 .B SparesMissing
2222 If
2223 .I mdadm
2224 has been told, via the config file, that an array should have a certain
2225 number of spare devices, and
2226 .I mdadm
2227 detects that it has fewer than this number when it first sees the
2228 array, it will report a
2229 .B SparesMissing
2230 message.
2231 (syslog priority: Warning)
2232
2233 .TP
2234 .B TestMessage
2235 An array was found at startup, and the
2236 .B \-\-test
2237 flag was given.
2238 (syslog priority: Info)
2239 .RE
2240
2241 Only
2242 .B Fail,
2243 .B FailSpare,
2244 .B DegradedArray,
2245 .B SparesMissing
2246 and
2247 .B TestMessage
2248 cause Email to be sent. All events cause the program to be run.
2249 The program is run with two or three arguments: the event
2250 name, the array device and possibly a second device.
2251
2252 Each event has an associated array device (e.g.
2253 .BR /dev/md1 )
2254 and possibly a second device. For
2255 .BR Fail ,
2256 .BR FailSpare ,
2257 and
2258 .B SpareActive
2259 the second device is the relevant component device.
2260 For
2261 .B MoveSpare
2262 the second device is the array that the spare was moved from.
2263
2264 For
2265 .I mdadm
2266 to move spares from one array to another, the different arrays need to
2267 be labeled with the same
2268 .B spare-group
2269 or the spares must be allowed to migrate through matching POLICY domains
2270 in the configuration file. The
2271 .B spare-group
2272 name can be any string; it is only necessary that different spare
2273 groups use different names.
2274
2275 When
2276 .I mdadm
2277 detects that an array in a spare group has fewer active
2278 devices than necessary for the complete array, and has no spare
2279 devices, it will look for another array in the same spare group that
2280 has a full complement of working drive and a spare. It will then
2281 attempt to remove the spare from the second drive and add it to the
2282 first.
2283 If the removal succeeds but the adding fails, then it is added back to
2284 the original array.
2285
2286 If the spare group for a degraded array is not defined,
2287 .I mdadm
2288 will look at the rules of spare migration specified by POLICY lines in
2289 .B mdadm.conf
2290 and then follow similar steps as above if a matching spare is found.
2291
2292 .SH GROW MODE
2293 The GROW mode is used for changing the size or shape of an active
2294 array.
2295 For this to work, the kernel must support the necessary change.
2296 Various types of growth are being added during 2.6 development.
2297
2298 Currently the supported changes include
2299 .IP \(bu 4
2300 change the "size" attribute for RAID1, RAID4, RAID5 and RAID6.
2301 .IP \(bu 4
2302 increase or decrease the "raid\-devices" attribute of RAID0, RAID1, RAID4,
2303 RAID5, and RAID6.
2304 .IP \(bu 4
2305 change the chunk-size and layout of RAID0, RAID4, RAID5 and RAID6.
2306 .IP \(bu 4
2307 convert between RAID1 and RAID5, between RAID5 and RAID6, between
2308 RAID0, RAID4, and RAID5, and between RAID0 and RAID10 (in the near-2 mode).
2309 .IP \(bu 4
2310 add a write-intent bitmap to any array which supports these bitmaps, or
2311 remove a write-intent bitmap from such an array.
2312 .PP
2313
2314 Using GROW on containers is currently supported only for Intel's IMSM
2315 container format. The number of devices in a container can be
2316 increased - which affects all arrays in the container - or an array
2317 in a container can be converted between levels where those levels are
2318 supported by the container, and the conversion is on of those listed
2319 above. Resizing arrays in an IMSM container with
2320 .B "--grow --size"
2321 is not yet supported.
2322
2323 Grow functionality (e.g. expand a number of raid devices) for Intel's
2324 IMSM container format has an experimental status. It is guarded by the
2325 .B MDADM_EXPERIMENTAL
2326 environment variable which must be set to '1' for a GROW command to
2327 succeed.
2328 This is for the following reasons:
2329
2330 .IP 1.
2331 Intel's native IMSM check-pointing is not fully tested yet.
2332 This can causes IMSM incompatibility during the grow process: an array
2333 which is growing cannot roam between Microsoft Windows(R) and Linux
2334 systems.
2335
2336 .IP 2.
2337 Interrupting a grow operation is not recommended, because it
2338 has not been fully tested for Intel's IMSM container format yet.
2339
2340 .PP
2341 Note: Intel's native checkpointing doesn't use
2342 .B --backup-file
2343 option and it is transparent for assembly feature.
2344
2345 .SS SIZE CHANGES
2346 Normally when an array is built the "size" is taken from the smallest
2347 of the drives. If all the small drives in an arrays are, one at a
2348 time, removed and replaced with larger drives, then you could have an
2349 array of large drives with only a small amount used. In this
2350 situation, changing the "size" with "GROW" mode will allow the extra
2351 space to start being used. If the size is increased in this way, a
2352 "resync" process will start to make sure the new parts of the array
2353 are synchronised.
2354
2355 Note that when an array changes size, any filesystem that may be
2356 stored in the array will not automatically grow or shrink to use or
2357 vacate the space. The
2358 filesystem will need to be explicitly told to use the extra space
2359 after growing, or to reduce its size
2360 .B prior
2361 to shrinking the array.
2362
2363 Also the size of an array cannot be changed while it has an active
2364 bitmap. If an array has a bitmap, it must be removed before the size
2365 can be changed. Once the change is complete a new bitmap can be created.
2366
2367 .SS RAID\-DEVICES CHANGES
2368
2369 A RAID1 array can work with any number of devices from 1 upwards
2370 (though 1 is not very useful). There may be times which you want to
2371 increase or decrease the number of active devices. Note that this is
2372 different to hot-add or hot-remove which changes the number of
2373 inactive devices.
2374
2375 When reducing the number of devices in a RAID1 array, the slots which
2376 are to be removed from the array must already be vacant. That is, the
2377 devices which were in those slots must be failed and removed.
2378
2379 When the number of devices is increased, any hot spares that are
2380 present will be activated immediately.
2381
2382 Changing the number of active devices in a RAID5 or RAID6 is much more
2383 effort. Every block in the array will need to be read and written
2384 back to a new location. From 2.6.17, the Linux Kernel is able to
2385 increase the number of devices in a RAID5 safely, including restarting
2386 an interrupted "reshape". From 2.6.31, the Linux Kernel is able to
2387 increase or decrease the number of devices in a RAID5 or RAID6.
2388
2389 From 2.6.35, the Linux Kernel is able to convert a RAID0 in to a RAID4
2390 or RAID5.
2391 .I mdadm
2392 uses this functionality and the ability to add
2393 devices to a RAID4 to allow devices to be added to a RAID0. When
2394 requested to do this,
2395 .I mdadm
2396 will convert the RAID0 to a RAID4, add the necessary disks and make
2397 the reshape happen, and then convert the RAID4 back to RAID0.
2398
2399 When decreasing the number of devices, the size of the array will also
2400 decrease. If there was data in the array, it could get destroyed and
2401 this is not reversible, so you should firstly shrink the filesystem on
2402 the array to fit within the new size. To help prevent accidents,
2403 .I mdadm
2404 requires that the size of the array be decreased first with
2405 .BR "mdadm --grow --array-size" .
2406 This is a reversible change which simply makes the end of the array
2407 inaccessible. The integrity of any data can then be checked before
2408 the non-reversible reduction in the number of devices is request.
2409
2410 When relocating the first few stripes on a RAID5 or RAID6, it is not
2411 possible to keep the data on disk completely consistent and
2412 crash-proof. To provide the required safety, mdadm disables writes to
2413 the array while this "critical section" is reshaped, and takes a
2414 backup of the data that is in that section. For grows, this backup may be
2415 stored in any spare devices that the array has, however it can also be
2416 stored in a separate file specified with the
2417 .B \-\-backup\-file
2418 option, and is required to be specified for shrinks, RAID level
2419 changes and layout changes. If this option is used, and the system
2420 does crash during the critical period, the same file must be passed to
2421 .B \-\-assemble
2422 to restore the backup and reassemble the array. When shrinking rather
2423 than growing the array, the reshape is done from the end towards the
2424 beginning, so the "critical section" is at the end of the reshape.
2425
2426 .SS LEVEL CHANGES
2427
2428 Changing the RAID level of any array happens instantaneously. However
2429 in the RAID5 to RAID6 case this requires a non-standard layout of the
2430 RAID6 data, and in the RAID6 to RAID5 case that non-standard layout is
2431 required before the change can be accomplished. So while the level
2432 change is instant, the accompanying layout change can take quite a
2433 long time. A
2434 .B \-\-backup\-file
2435 is required. If the array is not simultaneously being grown or
2436 shrunk, so that the array size will remain the same - for example,
2437 reshaping a 3-drive RAID5 into a 4-drive RAID6 - the backup file will
2438 be used not just for a "cricital section" but throughout the reshape
2439 operation, as described below under LAYOUT CHANGES.
2440
2441 .SS CHUNK-SIZE AND LAYOUT CHANGES
2442
2443 Changing the chunk-size of layout without also changing the number of
2444 devices as the same time will involve re-writing all blocks in-place.
2445 To ensure against data loss in the case of a crash, a
2446 .B --backup-file
2447 must be provided for these changes. Small sections of the array will
2448 be copied to the backup file while they are being rearranged. This
2449 means that all the data is copied twice, once to the backup and once
2450 to the new layout on the array, so this type of reshape will go very
2451 slowly.
2452
2453 If the reshape is interrupted for any reason, this backup file must be
2454 made available to
2455 .B "mdadm --assemble"
2456 so the array can be reassembled. Consequently the file cannot be
2457 stored on the device being reshaped.
2458
2459
2460 .SS BITMAP CHANGES
2461
2462 A write-intent bitmap can be added to, or removed from, an active
2463 array. Either internal bitmaps, or bitmaps stored in a separate file,
2464 can be added. Note that if you add a bitmap stored in a file which is
2465 in a filesystem that is on the RAID array being affected, the system
2466 will deadlock. The bitmap must be on a separate filesystem.
2467
2468 .SH INCREMENTAL MODE
2469
2470 .HP 12
2471 Usage:
2472 .B mdadm \-\-incremental
2473 .RB [ \-\-run ]
2474 .RB [ \-\-quiet ]
2475 .I component-device
2476 .HP 12
2477 Usage:
2478 .B mdadm \-\-incremental \-\-fail
2479 .I component-device
2480 .HP 12
2481 Usage:
2482 .B mdadm \-\-incremental \-\-rebuild\-map
2483 .HP 12
2484 Usage:
2485 .B mdadm \-\-incremental \-\-run \-\-scan
2486
2487 .PP
2488 This mode is designed to be used in conjunction with a device
2489 discovery system. As devices are found in a system, they can be
2490 passed to
2491 .B "mdadm \-\-incremental"
2492 to be conditionally added to an appropriate array.
2493
2494 Conversely, it can also be used with the
2495 .B \-\-fail
2496 flag to do just the opposite and find whatever array a particular device
2497 is part of and remove the device from that array.
2498
2499 If the device passed is a
2500 .B CONTAINER
2501 device created by a previous call to
2502 .IR mdadm ,
2503 then rather than trying to add that device to an array, all the arrays
2504 described by the metadata of the container will be started.
2505
2506 .I mdadm
2507 performs a number of tests to determine if the device is part of an
2508 array, and which array it should be part of. If an appropriate array
2509 is found, or can be created,
2510 .I mdadm
2511 adds the device to the array and conditionally starts the array.
2512
2513 Note that
2514 .I mdadm
2515 will normally only add devices to an array which were previously working
2516 (active or spare) parts of that array. The support for automatic
2517 inclusion of a new drive as a spare in some array requires
2518 a configuration through POLICY in config file.
2519
2520 The tests that
2521 .I mdadm
2522 makes are as follow:
2523 .IP +
2524 Is the device permitted by
2525 .BR mdadm.conf ?
2526 That is, is it listed in a
2527 .B DEVICES
2528 line in that file. If
2529 .B DEVICES
2530 is absent then the default it to allow any device. Similar if
2531 .B DEVICES
2532 contains the special word
2533 .B partitions
2534 then any device is allowed. Otherwise the device name given to
2535 .I mdadm
2536 must match one of the names or patterns in a
2537 .B DEVICES
2538 line.
2539
2540 .IP +
2541 Does the device have a valid md superblock? If a specific metadata
2542 version is requested with
2543 .B \-\-metadata
2544 or
2545 .B \-e
2546 then only that style of metadata is accepted, otherwise
2547 .I mdadm
2548 finds any known version of metadata. If no
2549 .I md
2550 metadata is found, the device may be still added to an array
2551 as a spare if POLICY allows.
2552
2553 .ig
2554 .IP +
2555 Does the metadata match an expected array?
2556 The metadata can match in two ways. Either there is an array listed
2557 in
2558 .B mdadm.conf
2559 which identifies the array (either by UUID, by name, by device list,
2560 or by minor-number), or the array was created with a
2561 .B homehost
2562 specified and that
2563 .B homehost
2564 matches the one in
2565 .B mdadm.conf
2566 or on the command line.
2567 If
2568 .I mdadm
2569 is not able to positively identify the array as belonging to the
2570 current host, the device will be rejected.
2571 ..
2572
2573 .PP
2574 .I mdadm
2575 keeps a list of arrays that it has partially assembled in
2576 .BR {MAP_PATH} .
2577 If no array exists which matches
2578 the metadata on the new device,
2579 .I mdadm
2580 must choose a device name and unit number. It does this based on any
2581 name given in
2582 .B mdadm.conf
2583 or any name information stored in the metadata. If this name
2584 suggests a unit number, that number will be used, otherwise a free
2585 unit number will be chosen. Normally
2586 .I mdadm
2587 will prefer to create a partitionable array, however if the
2588 .B CREATE
2589 line in
2590 .B mdadm.conf
2591 suggests that a non-partitionable array is preferred, that will be
2592 honoured.
2593
2594 If the array is not found in the config file and its metadata does not
2595 identify it as belonging to the "homehost", then
2596 .I mdadm
2597 will choose a name for the array which is certain not to conflict with
2598 any array which does belong to this host. It does this be adding an
2599 underscore and a small number to the name preferred by the metadata.
2600
2601 Once an appropriate array is found or created and the device is added,
2602 .I mdadm
2603 must decide if the array is ready to be started. It will
2604 normally compare the number of available (non-spare) devices to the
2605 number of devices that the metadata suggests need to be active. If
2606 there are at least that many, the array will be started. This means
2607 that if any devices are missing the array will not be restarted.
2608
2609 As an alternative,
2610 .B \-\-run
2611 may be passed to
2612 .I mdadm
2613 in which case the array will be run as soon as there are enough
2614 devices present for the data to be accessible. For a RAID1, that
2615 means one device will start the array. For a clean RAID5, the array
2616 will be started as soon as all but one drive is present.
2617
2618 Note that neither of these approaches is really ideal. If it can
2619 be known that all device discovery has completed, then
2620 .br
2621 .B " mdadm \-IRs"
2622 .br
2623 can be run which will try to start all arrays that are being
2624 incrementally assembled. They are started in "read-auto" mode in
2625 which they are read-only until the first write request. This means
2626 that no metadata updates are made and no attempt at resync or recovery
2627 happens. Further devices that are found before the first write can
2628 still be added safely.
2629
2630 .SH ENVIRONMENT
2631 This section describes environment variables that affect how mdadm
2632 operates.
2633
2634 .TP
2635 .B MDADM_NO_MDMON
2636 Setting this value to 1 will prevent mdadm from automatically launching
2637 mdmon. This variable is intended primarily for debugging mdadm/mdmon.
2638
2639 .TP
2640 .B MDADM_NO_UDEV
2641 Normally,
2642 .I mdadm
2643 does not create any device nodes in /dev, but leaves that task to
2644 .IR udev .
2645 If
2646 .I udev
2647 appears not to be configured, or if this environment variable is set
2648 to '1', the
2649 .I mdadm
2650 will create and devices that are needed.
2651
2652 .SH EXAMPLES
2653
2654 .B " mdadm \-\-query /dev/name-of-device"
2655 .br
2656 This will find out if a given device is a RAID array, or is part of
2657 one, and will provide brief information about the device.
2658
2659 .B " mdadm \-\-assemble \-\-scan"
2660 .br
2661 This will assemble and start all arrays listed in the standard config
2662 file. This command will typically go in a system startup file.
2663
2664 .B " mdadm \-\-stop \-\-scan"
2665 .br
2666 This will shut down all arrays that can be shut down (i.e. are not
2667 currently in use). This will typically go in a system shutdown script.
2668
2669 .B " mdadm \-\-follow \-\-scan \-\-delay=120"
2670 .br
2671 If (and only if) there is an Email address or program given in the
2672 standard config file, then
2673 monitor the status of all arrays listed in that file by
2674 polling them ever 2 minutes.
2675
2676 .B " mdadm \-\-create /dev/md0 \-\-level=1 \-\-raid\-devices=2 /dev/hd[ac]1"
2677 .br
2678 Create /dev/md0 as a RAID1 array consisting of /dev/hda1 and /dev/hdc1.
2679
2680 .br
2681 .B " echo 'DEVICE /dev/hd*[0\-9] /dev/sd*[0\-9]' > mdadm.conf"
2682 .br
2683 .B " mdadm \-\-detail \-\-scan >> mdadm.conf"
2684 .br
2685 This will create a prototype config file that describes currently
2686 active arrays that are known to be made from partitions of IDE or SCSI drives.
2687 This file should be reviewed before being used as it may
2688 contain unwanted detail.
2689
2690 .B " echo 'DEVICE /dev/hd[a\-z] /dev/sd*[a\-z]' > mdadm.conf"
2691 .br
2692 .B " mdadm \-\-examine \-\-scan \-\-config=mdadm.conf >> mdadm.conf"
2693 .br
2694 This will find arrays which could be assembled from existing IDE and
2695 SCSI whole drives (not partitions), and store the information in the
2696 format of a config file.
2697 This file is very likely to contain unwanted detail, particularly
2698 the
2699 .B devices=
2700 entries. It should be reviewed and edited before being used as an
2701 actual config file.
2702
2703 .B " mdadm \-\-examine \-\-brief \-\-scan \-\-config=partitions"
2704 .br
2705 .B " mdadm \-Ebsc partitions"
2706 .br
2707 Create a list of devices by reading
2708 .BR /proc/partitions ,
2709 scan these for RAID superblocks, and printout a brief listing of all
2710 that were found.
2711
2712 .B " mdadm \-Ac partitions \-m 0 /dev/md0"
2713 .br
2714 Scan all partitions and devices listed in
2715 .BR /proc/partitions
2716 and assemble
2717 .B /dev/md0
2718 out of all such devices with a RAID superblock with a minor number of 0.
2719
2720 .B " mdadm \-\-monitor \-\-scan \-\-daemonise > /run/mdadm/mon.pid"
2721 .br
2722 If config file contains a mail address or alert program, run mdadm in
2723 the background in monitor mode monitoring all md devices. Also write
2724 pid of mdadm daemon to
2725 .BR /run/mdadm/mon.pid .
2726
2727 .B " mdadm \-Iq /dev/somedevice"
2728 .br
2729 Try to incorporate newly discovered device into some array as
2730 appropriate.
2731
2732 .B " mdadm \-\-incremental \-\-rebuild\-map \-\-run \-\-scan"
2733 .br
2734 Rebuild the array map from any current arrays, and then start any that
2735 can be started.
2736
2737 .B " mdadm /dev/md4 --fail detached --remove detached"
2738 .br
2739 Any devices which are components of /dev/md4 will be marked as faulty
2740 and then remove from the array.
2741
2742 .B " mdadm --grow /dev/md4 --level=6 --backup-file=/root/backup-md4"
2743 .br
2744 The array
2745 .B /dev/md4
2746 which is currently a RAID5 array will be converted to RAID6. There
2747 should normally already be a spare drive attached to the array as a
2748 RAID6 needs one more drive than a matching RAID5.
2749
2750 .B " mdadm --create /dev/md/ddf --metadata=ddf --raid-disks 6 /dev/sd[a-f]"
2751 .br
2752 Create a DDF array over 6 devices.
2753
2754 .B " mdadm --create /dev/md/home -n3 -l5 -z 30000000 /dev/md/ddf"
2755 .br
2756 Create a RAID5 array over any 3 devices in the given DDF set. Use
2757 only 30 gigabytes of each device.
2758
2759 .B " mdadm -A /dev/md/ddf1 /dev/sd[a-f]"
2760 .br
2761 Assemble a pre-exist ddf array.
2762
2763 .B " mdadm -I /dev/md/ddf1"
2764 .br
2765 Assemble all arrays contained in the ddf array, assigning names as
2766 appropriate.
2767
2768 .B " mdadm \-\-create \-\-help"
2769 .br
2770 Provide help about the Create mode.
2771
2772 .B " mdadm \-\-config \-\-help"
2773 .br
2774 Provide help about the format of the config file.
2775
2776 .B " mdadm \-\-help"
2777 .br
2778 Provide general help.
2779
2780 .SH FILES
2781
2782 .SS /proc/mdstat
2783
2784 If you're using the
2785 .B /proc
2786 filesystem,
2787 .B /proc/mdstat
2788 lists all active md devices with information about them.
2789 .I mdadm
2790 uses this to find arrays when
2791 .B \-\-scan
2792 is given in Misc mode, and to monitor array reconstruction
2793 on Monitor mode.
2794
2795 .SS /etc/mdadm.conf
2796
2797 The config file lists which devices may be scanned to see if
2798 they contain MD super block, and gives identifying information
2799 (e.g. UUID) about known MD arrays. See
2800 .BR mdadm.conf (5)
2801 for more details.
2802
2803 .SS {MAP_PATH}
2804 When
2805 .B \-\-incremental
2806 mode is used, this file gets a list of arrays currently being created.
2807
2808 .SH DEVICE NAMES
2809
2810 .I mdadm
2811 understand two sorts of names for array devices.
2812
2813 The first is the so-called 'standard' format name, which matches the
2814 names used by the kernel and which appear in
2815 .IR /proc/mdstat .
2816
2817 The second sort can be freely chosen, but must reside in
2818 .IR /dev/md/ .
2819 When giving a device name to
2820 .I mdadm
2821 to create or assemble an array, either full path name such as
2822 .I /dev/md0
2823 or
2824 .I /dev/md/home
2825 can be given, or just the suffix of the second sort of name, such as
2826 .I home
2827 can be given.
2828
2829 When
2830 .I mdadm
2831 chooses device names during auto-assembly or incremental assembly, it
2832 will sometimes add a small sequence number to the end of the name to
2833 avoid conflicted between multiple arrays that have the same name. If
2834 .I mdadm
2835 can reasonably determine that the array really is meant for this host,
2836 either by a hostname in the metadata, or by the presence of the array
2837 in
2838 .BR mdadm.conf ,
2839 then it will leave off the suffix if possible.
2840 Also if the homehost is specified as
2841 .B <ignore>
2842 .I mdadm
2843 will only use a suffix if a different array of the same name already
2844 exists or is listed in the config file.
2845
2846 The standard names for non-partitioned arrays (the only sort of md
2847 array available in 2.4 and earlier) are of the form
2848 .IP
2849 /dev/mdNN
2850 .PP
2851 where NN is a number.
2852 The standard names for partitionable arrays (as available from 2.6
2853 onwards) are of the form
2854 .IP
2855 /dev/md_dNN
2856 .PP
2857 Partition numbers should be indicated by added "pMM" to these, thus "/dev/md/d1p2".
2858 .PP
2859 From kernel version, 2.6.28 the "non-partitioned array" can actually
2860 be partitioned. So the "md_dNN" names are no longer needed, and
2861 partitions such as "/dev/mdNNpXX" are possible.
2862
2863 .SH NOTE
2864 .I mdadm
2865 was previously known as
2866 .IR mdctl .
2867 .P
2868 .I mdadm
2869 is completely separate from the
2870 .I raidtools
2871 package, and does not use the
2872 .I /etc/raidtab
2873 configuration file at all.
2874
2875 .SH SEE ALSO
2876 For further information on mdadm usage, MD and the various levels of
2877 RAID, see:
2878 .IP
2879 .B http://raid.wiki.kernel.org/
2880 .PP
2881 (based upon Jakob \(/Ostergaard's Software\-RAID.HOWTO)
2882 .\".PP
2883 .\"for new releases of the RAID driver check out:
2884 .\"
2885 .\".IP
2886 .\".UR ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2887 .\"ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2888 .\".UE
2889 .\".PP
2890 .\"or
2891 .\".IP
2892 .\".UR http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2893 .\"http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2894 .\".UE
2895 .PP
2896 The latest version of
2897 .I mdadm
2898 should always be available from
2899 .IP
2900 .B http://www.kernel.org/pub/linux/utils/raid/mdadm/
2901 .PP
2902 Related man pages:
2903 .PP
2904 .IR mdmon (8),
2905 .IR mdadm.conf (5),
2906 .IR md (4).
2907 .PP
2908 .IR raidtab (5),
2909 .IR raid0run (8),
2910 .IR raidstop (8),
2911 .IR mkraid (8).