]> git.ipfire.org Git - thirdparty/mdadm.git/blob - mdadm.8
Merge branch 'subarray' into for-neil
[thirdparty/mdadm.git] / mdadm.8
1 .\" -*- nroff -*-
2 .\" Copyright Neil Brown and others.
3 .\" This program is free software; you can redistribute it and/or modify
4 .\" it under the terms of the GNU General Public License as published by
5 .\" the Free Software Foundation; either version 2 of the License, or
6 .\" (at your option) any later version.
7 .\" See file COPYING in distribution for details.
8 .TH MDADM 8 "" v3.1.2
9 .SH NAME
10 mdadm \- manage MD devices
11 .I aka
12 Linux Software RAID
13
14 .SH SYNOPSIS
15
16 .BI mdadm " [mode] <raiddevice> [options] <component-devices>"
17
18 .SH DESCRIPTION
19 RAID devices are virtual devices created from two or more
20 real block devices. This allows multiple devices (typically disk
21 drives or partitions thereof) to be combined into a single device to
22 hold (for example) a single filesystem.
23 Some RAID levels include redundancy and so can survive some degree of
24 device failure.
25
26 Linux Software RAID devices are implemented through the md (Multiple
27 Devices) device driver.
28
29 Currently, Linux supports
30 .B LINEAR
31 md devices,
32 .B RAID0
33 (striping),
34 .B RAID1
35 (mirroring),
36 .BR RAID4 ,
37 .BR RAID5 ,
38 .BR RAID6 ,
39 .BR RAID10 ,
40 .BR MULTIPATH ,
41 .BR FAULTY ,
42 and
43 .BR CONTAINER .
44
45 .B MULTIPATH
46 is not a Software RAID mechanism, but does involve
47 multiple devices:
48 each device is a path to one common physical storage device.
49 New installations should not use md/multipath as it is not well
50 supported and has no ongoing development. Use the Device Mapper based
51 multipath-tools instead.
52
53 .B FAULTY
54 is also not true RAID, and it only involves one device. It
55 provides a layer over a true device that can be used to inject faults.
56
57 .B CONTAINER
58 is different again. A
59 .B CONTAINER
60 is a collection of devices that are
61 managed as a set. This is similar to the set of devices connected to
62 a hardware RAID controller. The set of devices may contain a number
63 of different RAID arrays each utilising some (or all) of the blocks from a
64 number of the devices in the set. For example, two devices in a 5-device set
65 might form a RAID1 using the whole devices. The remaining three might
66 have a RAID5 over the first half of each device, and a RAID0 over the
67 second half.
68
69 With a
70 .BR CONTAINER ,
71 there is one set of metadata that describes all of
72 the arrays in the container. So when
73 .I mdadm
74 creates a
75 .B CONTAINER
76 device, the device just represents the metadata. Other normal arrays (RAID1
77 etc) can be created inside the container.
78
79 .SH MODES
80 mdadm has several major modes of operation:
81 .TP
82 .B Assemble
83 Assemble the components of a previously created
84 array into an active array. Components can be explicitly given
85 or can be searched for.
86 .I mdadm
87 checks that the components
88 do form a bona fide array, and can, on request, fiddle superblock
89 information so as to assemble a faulty array.
90
91 .TP
92 .B Build
93 Build an array that doesn't have per-device metadata (superblocks). For these
94 sorts of arrays,
95 .I mdadm
96 cannot differentiate between initial creation and subsequent assembly
97 of an array. It also cannot perform any checks that appropriate
98 components have been requested. Because of this, the
99 .B Build
100 mode should only be used together with a complete understanding of
101 what you are doing.
102
103 .TP
104 .B Create
105 Create a new array with per-device metadata (superblocks).
106 Appropriate metadata is written to each device, and then the array
107 comprising those devices is activated. A 'resync' process is started
108 to make sure that the array is consistent (e.g. both sides of a mirror
109 contain the same data) but the content of the device is left otherwise
110 untouched.
111 The array can be used as soon as it has been created. There is no
112 need to wait for the initial resync to finish.
113
114 .TP
115 .B "Follow or Monitor"
116 Monitor one or more md devices and act on any state changes. This is
117 only meaningful for RAID1, 4, 5, 6, 10 or multipath arrays, as
118 only these have interesting state. RAID0 or Linear never have
119 missing, spare, or failed drives, so there is nothing to monitor.
120
121 .TP
122 .B "Grow"
123 Grow (or shrink) an array, or otherwise reshape it in some way.
124 Currently supported growth options including changing the active size
125 of component devices and changing the number of active devices in RAID
126 levels 1/4/5/6, changing the RAID level between 1, 5, and 6, changing
127 the chunk size and layout for RAID5 and RAID5, as well as adding or
128 removing a write-intent bitmap.
129
130 .TP
131 .B "Incremental Assembly"
132 Add a single device to an appropriate array. If the addition of the
133 device makes the array runnable, the array will be started.
134 This provides a convenient interface to a
135 .I hot-plug
136 system. As each device is detected,
137 .I mdadm
138 has a chance to include it in some array as appropriate.
139
140 If a
141 .B CONTAINER
142 is passed to
143 .I mdadm
144 in this mode, then any arrays within that container will be assembled
145 and started.
146
147 .TP
148 .B Manage
149 This is for doing things to specific components of an array such as
150 adding new spares and removing faulty devices.
151
152 .TP
153 .B Misc
154 This is an 'everything else' mode that supports operations on active
155 arrays, operations on component devices such as erasing old superblocks, and
156 information gathering operations.
157 .\"This mode allows operations on independent devices such as examine MD
158 .\"superblocks, erasing old superblocks and stopping active arrays.
159
160 .TP
161 .B Auto-detect
162 This mode does not act on a specific device or array, but rather it
163 requests the Linux Kernel to activate any auto-detected arrays.
164 .SH OPTIONS
165
166 .SH Options for selecting a mode are:
167
168 .TP
169 .BR \-A ", " \-\-assemble
170 Assemble a pre-existing array.
171
172 .TP
173 .BR \-B ", " \-\-build
174 Build a legacy array without superblocks.
175
176 .TP
177 .BR \-C ", " \-\-create
178 Create a new array.
179
180 .TP
181 .BR \-F ", " \-\-follow ", " \-\-monitor
182 Select
183 .B Monitor
184 mode.
185
186 .TP
187 .BR \-G ", " \-\-grow
188 Change the size or shape of an active array.
189
190 .TP
191 .BR \-I ", " \-\-incremental
192 Add a single device into an appropriate array, and possibly start the array.
193
194 .TP
195 .B \-\-auto-detect
196 Request that the kernel starts any auto-detected arrays. This can only
197 work if
198 .I md
199 is compiled into the kernel \(em not if it is a module.
200 Arrays can be auto-detected by the kernel if all the components are in
201 primary MS-DOS partitions with partition type
202 .BR FD ,
203 and all use v0.90 metadata.
204 In-kernel autodetect is not recommended for new installations. Using
205 .I mdadm
206 to detect and assemble arrays \(em possibly in an
207 .I initrd
208 \(em is substantially more flexible and should be preferred.
209
210 .P
211 If a device is given before any options, or if the first option is
212 .BR \-\-add ,
213 .BR \-\-fail ,
214 or
215 .BR \-\-remove ,
216 then the MANAGE mode is assumed.
217 Anything other than these will cause the
218 .B Misc
219 mode to be assumed.
220
221 .SH Options that are not mode-specific are:
222
223 .TP
224 .BR \-h ", " \-\-help
225 Display general help message or, after one of the above options, a
226 mode-specific help message.
227
228 .TP
229 .B \-\-help\-options
230 Display more detailed help about command line parsing and some commonly
231 used options.
232
233 .TP
234 .BR \-V ", " \-\-version
235 Print version information for mdadm.
236
237 .TP
238 .BR \-v ", " \-\-verbose
239 Be more verbose about what is happening. This can be used twice to be
240 extra-verbose.
241 The extra verbosity currently only affects
242 .B \-\-detail \-\-scan
243 and
244 .BR "\-\-examine \-\-scan" .
245
246 .TP
247 .BR \-q ", " \-\-quiet
248 Avoid printing purely informative messages. With this,
249 .I mdadm
250 will be silent unless there is something really important to report.
251
252 .TP
253 .BR \-f ", " \-\-force
254 Be more forceful about certain operations. See the various modes for
255 the exact meaning of this option in different contexts.
256
257 .TP
258 .BR \-c ", " \-\-config=
259 Specify the config file. Default is to use
260 .BR /etc/mdadm.conf ,
261 or if that is missing then
262 .BR /etc/mdadm/mdadm.conf .
263 If the config file given is
264 .B "partitions"
265 then nothing will be read, but
266 .I mdadm
267 will act as though the config file contained exactly
268 .B "DEVICE partitions containers"
269 and will read
270 .B /proc/partitions
271 to find a list of devices to scan, and
272 .B /proc/mdstat
273 to find a list of containers to examine.
274 If the word
275 .B "none"
276 is given for the config file, then
277 .I mdadm
278 will act as though the config file were empty.
279
280 .TP
281 .BR \-s ", " \-\-scan
282 Scan config file or
283 .B /proc/mdstat
284 for missing information.
285 In general, this option gives
286 .I mdadm
287 permission to get any missing information (like component devices,
288 array devices, array identities, and alert destination) from the
289 configuration file (see previous option);
290 one exception is MISC mode when using
291 .B \-\-detail
292 or
293 .B \-\-stop,
294 in which case
295 .B \-\-scan
296 says to get a list of array devices from
297 .BR /proc/mdstat .
298
299 .TP
300 .BR \-e ", " \-\-metadata=
301 Declare the style of RAID metadata (superblock) to be used. The
302 default is 1.2 for
303 .BR \-\-create ,
304 and to guess for other operations.
305 The default can be overridden by setting the
306 .B metadata
307 value for the
308 .B CREATE
309 keyword in
310 .BR mdadm.conf .
311
312 Options are:
313 .RS
314 .IP "0, 0.90"
315 Use the original 0.90 format superblock. This format limits arrays to
316 28 component devices and limits component devices of levels 1 and
317 greater to 2 terabytes.
318 .IP "1, 1.0, 1.1, 1.2 default"
319 Use the new version-1 format superblock. This has few restrictions.
320 The different sub-versions store the superblock at different locations
321 on the device, either at the end (for 1.0), at the start (for 1.1) or
322 4K from the start (for 1.2). '1' is equivalent to '1.0', 'default' is
323 equivalent to '1.2'.
324 .IP ddf
325 Use the "Industry Standard" DDF (Disk Data Format) format defined by
326 SNIA.
327 When creating a DDF array a
328 .B CONTAINER
329 will be created, and normal arrays can be created in that container.
330 .IP imsm
331 Use the Intel(R) Matrix Storage Manager metadata format. This creates a
332 .B CONTAINER
333 which is managed in a similar manner to DDF, and is supported by an
334 option-rom on some platforms:
335 .IP
336 .B http://www.intel.com/design/chipsets/matrixstorage_sb.htm
337 .PP
338 .RE
339
340 .TP
341 .B \-\-homehost=
342 This will override any
343 .B HOMEHOST
344 setting in the config file and provides the identity of the host which
345 should be considered the home for any arrays.
346
347 When creating an array, the
348 .B homehost
349 will be recorded in the metadata. For version-1 superblocks, it will
350 be prefixed to the array name. For version-0.90 superblocks, part of
351 the SHA1 hash of the hostname will be stored in the later half of the
352 UUID.
353
354 When reporting information about an array, any array which is tagged
355 for the given homehost will be reported as such.
356
357 When using Auto-Assemble, only arrays tagged for the given homehost
358 will be allowed to use 'local' names (i.e. not ending in '_' followed
359 by a digit string). See below under
360 .BR "Auto Assembly" .
361
362 .SH For create, build, or grow:
363
364 .TP
365 .BR \-n ", " \-\-raid\-devices=
366 Specify the number of active devices in the array. This, plus the
367 number of spare devices (see below) must equal the number of
368 .I component-devices
369 (including "\fBmissing\fP" devices)
370 that are listed on the command line for
371 .BR \-\-create .
372 Setting a value of 1 is probably
373 a mistake and so requires that
374 .B \-\-force
375 be specified first. A value of 1 will then be allowed for linear,
376 multipath, RAID0 and RAID1. It is never allowed for RAID4, RAID5 or RAID6.
377 .br
378 This number can only be changed using
379 .B \-\-grow
380 for RAID1, RAID4, RAID5 and RAID6 arrays, and only on kernels which provide
381 the necessary support.
382
383 .TP
384 .BR \-x ", " \-\-spare\-devices=
385 Specify the number of spare (eXtra) devices in the initial array.
386 Spares can also be added
387 and removed later. The number of component devices listed
388 on the command line must equal the number of RAID devices plus the
389 number of spare devices.
390
391 .TP
392 .BR \-z ", " \-\-size=
393 Amount (in Kibibytes) of space to use from each drive in RAID levels 1/4/5/6.
394 This must be a multiple of the chunk size, and must leave about 128Kb
395 of space at the end of the drive for the RAID superblock.
396 If this is not specified
397 (as it normally is not) the smallest drive (or partition) sets the
398 size, though if there is a variance among the drives of greater than 1%, a warning is
399 issued.
400
401 This value can be set with
402 .B \-\-grow
403 for RAID level 1/4/5/6. If the array was created with a size smaller
404 than the currently active drives, the extra space can be accessed
405 using
406 .BR \-\-grow .
407 The size can be given as
408 .B max
409 which means to choose the largest size that fits on all current drives.
410
411 This value can not be used with
412 .B CONTAINER
413 metadata such as DDF and IMSM.
414
415 .TP
416 .BR \-Z ", " \-\-array-size=
417 This is only meaningful with
418 .B \-\-grow
419 and its effect is not persistent: when the array is stopped an
420 restarted the default array size will be restored.
421
422 Setting the array-size causes the array to appear smaller to programs
423 that access the data. This is particularly needed before reshaping an
424 array so that it will be smaller. As the reshape is not reversible,
425 but setting the size with
426 .B \-\-array-size
427 is, it is required that the array size is reduced as appropriate
428 before the number of devices in the array is reduced.
429
430 .TP
431 .BR \-c ", " \-\-chunk=
432 Specify chunk size of kibibytes. The default when creating an
433 array is 512KB. To ensure compatibility with earlier versions, the
434 default when Building and array with no persistent metadata is 64KB.
435 This is only meaningful for RAID0, RAID4, RAID5, RAID6, and RAID10.
436
437 .TP
438 .BR \-\-rounding=
439 Specify rounding factor for a Linear array. The size of each
440 component will be rounded down to a multiple of this size.
441 This is a synonym for
442 .B \-\-chunk
443 but highlights the different meaning for Linear as compared to other
444 RAID levels. The default is 64K if a kernel earlier than 2.6.16 is in
445 use, and is 0K (i.e. no rounding) in later kernels.
446
447 .TP
448 .BR \-l ", " \-\-level=
449 Set RAID level. When used with
450 .BR \-\-create ,
451 options are: linear, raid0, 0, stripe, raid1, 1, mirror, raid4, 4,
452 raid5, 5, raid6, 6, raid10, 10, multipath, mp, faulty, container.
453 Obviously some of these are synonymous.
454
455 When a
456 .B CONTAINER
457 metadata type is requested, only the
458 .B container
459 level is permitted, and it does not need to be explicitly given.
460
461 When used with
462 .BR \-\-build ,
463 only linear, stripe, raid0, 0, raid1, multipath, mp, and faulty are valid.
464
465 Not yet supported with
466 .BR \-\-grow .
467
468 .TP
469 .BR \-p ", " \-\-layout=
470 This option configures the fine details of data layout for RAID5, RAID6,
471 and RAID10 arrays, and controls the failure modes for
472 .IR faulty .
473
474 The layout of the RAID5 parity block can be one of
475 .BR left\-asymmetric ,
476 .BR left\-symmetric ,
477 .BR right\-asymmetric ,
478 .BR right\-symmetric ,
479 .BR la ", " ra ", " ls ", " rs .
480 The default is
481 .BR left\-symmetric .
482
483 It is also possibly to cause RAID5 to use a RAID4-like layout by
484 choosing
485 .BR parity\-first ,
486 or
487 .BR parity\-last .
488
489 Finally for RAID5 there are DDF\-compatible layouts,
490 .BR ddf\-zero\-restart ,
491 .BR ddf\-N\-restart ,
492 and
493 .BR ddf\-N\-continue .
494
495 These same layouts are available for RAID6. There are also 4 layouts
496 that will provide an intermediate stage for converting between RAID5
497 and RAID6. These provide a layout which is identical to the
498 corresponding RAID5 layout on the first N\-1 devices, and has the 'Q'
499 syndrome (the second 'parity' block used by RAID6) on the last device.
500 These layouts are:
501 .BR left\-symmetric\-6 ,
502 .BR right\-symmetric\-6 ,
503 .BR left\-asymmetric\-6 ,
504 .BR right\-asymmetric\-6 ,
505 and
506 .BR parity\-first\-6 .
507
508 When setting the failure mode for level
509 .I faulty,
510 the options are:
511 .BR write\-transient ", " wt ,
512 .BR read\-transient ", " rt ,
513 .BR write\-persistent ", " wp ,
514 .BR read\-persistent ", " rp ,
515 .BR write\-all ,
516 .BR read\-fixable ", " rf ,
517 .BR clear ", " flush ", " none .
518
519 Each failure mode can be followed by a number, which is used as a period
520 between fault generation. Without a number, the fault is generated
521 once on the first relevant request. With a number, the fault will be
522 generated after that many requests, and will continue to be generated
523 every time the period elapses.
524
525 Multiple failure modes can be current simultaneously by using the
526 .B \-\-grow
527 option to set subsequent failure modes.
528
529 "clear" or "none" will remove any pending or periodic failure modes,
530 and "flush" will clear any persistent faults.
531
532 Finally, the layout options for RAID10 are one of 'n', 'o' or 'f' followed
533 by a small number. The default is 'n2'. The supported options are:
534
535 .I 'n'
536 signals 'near' copies. Multiple copies of one data block are at
537 similar offsets in different devices.
538
539 .I 'o'
540 signals 'offset' copies. Rather than the chunks being duplicated
541 within a stripe, whole stripes are duplicated but are rotated by one
542 device so duplicate blocks are on different devices. Thus subsequent
543 copies of a block are in the next drive, and are one chunk further
544 down.
545
546 .I 'f'
547 signals 'far' copies
548 (multiple copies have very different offsets).
549 See md(4) for more detail about 'near', 'offset', and 'far'.
550
551 The number is the number of copies of each datablock. 2 is normal, 3
552 can be useful. This number can be at most equal to the number of
553 devices in the array. It does not need to divide evenly into that
554 number (e.g. it is perfectly legal to have an 'n2' layout for an array
555 with an odd number of devices).
556
557 When an array is converted between RAID5 and RAID6 an intermediate
558 RAID6 layout is used in which the second parity block (Q) is always on
559 the last device. To convert a RAID5 to RAID6 and leave it in this new
560 layout (which does not require re-striping) use
561 .BR \-\-layout=preserve .
562 This will try to avoid any restriping.
563
564 The converse of this is
565 .B \-\-layout=normalise
566 which will change a non-standard RAID6 layout into a more standard
567 arrangement.
568
569 .TP
570 .BR \-\-parity=
571 same as
572 .B \-\-layout
573 (thus explaining the p of
574 .BR \-p ).
575
576 .TP
577 .BR \-b ", " \-\-bitmap=
578 Specify a file to store a write-intent bitmap in. The file should not
579 exist unless
580 .B \-\-force
581 is also given. The same file should be provided
582 when assembling the array. If the word
583 .B "internal"
584 is given, then the bitmap is stored with the metadata on the array,
585 and so is replicated on all devices. If the word
586 .B "none"
587 is given with
588 .B \-\-grow
589 mode, then any bitmap that is present is removed.
590
591 To help catch typing errors, the filename must contain at least one
592 slash ('/') if it is a real file (not 'internal' or 'none').
593
594 Note: external bitmaps are only known to work on ext2 and ext3.
595 Storing bitmap files on other filesystems may result in serious problems.
596
597 .TP
598 .BR \-\-bitmap\-chunk=
599 Set the chunksize of the bitmap. Each bit corresponds to that many
600 Kilobytes of storage.
601 When using a file based bitmap, the default is to use the smallest
602 size that is at-least 4 and requires no more than 2^21 chunks.
603 When using an
604 .B internal
605 bitmap, the chunksize defaults to 64Meg, or larger if necessary to
606 fit the bitmap into the available space.
607
608 .TP
609 .BR \-W ", " \-\-write\-mostly
610 subsequent devices listed in a
611 .BR \-\-build ,
612 .BR \-\-create ,
613 or
614 .B \-\-add
615 command will be flagged as 'write-mostly'. This is valid for RAID1
616 only and means that the 'md' driver will avoid reading from these
617 devices if at all possible. This can be useful if mirroring over a
618 slow link.
619
620 .TP
621 .BR \-\-write\-behind=
622 Specify that write-behind mode should be enabled (valid for RAID1
623 only). If an argument is specified, it will set the maximum number
624 of outstanding writes allowed. The default value is 256.
625 A write-intent bitmap is required in order to use write-behind
626 mode, and write-behind is only attempted on drives marked as
627 .IR write-mostly .
628
629 .TP
630 .BR \-\-assume\-clean
631 Tell
632 .I mdadm
633 that the array pre-existed and is known to be clean. It can be useful
634 when trying to recover from a major failure as you can be sure that no
635 data will be affected unless you actually write to the array. It can
636 also be used when creating a RAID1 or RAID10 if you want to avoid the
637 initial resync, however this practice \(em while normally safe \(em is not
638 recommended. Use this only if you really know what you are doing.
639 .IP
640 When the devices that will be part of a new array were filled
641 with zeros before creation the operator knows the array is
642 actually clean. If that is the case, such as after running
643 badblocks, this argument can be used to tell mdadm the
644 facts the operator knows.
645
646 .TP
647 .BR \-\-backup\-file=
648 This is needed when
649 .B \-\-grow
650 is used to increase the number of
651 raid-devices in a RAID5 if there are no spare devices available.
652 See the GROW MODE section below on RAID\-DEVICES CHANGES. The file
653 should be stored on a separate device, not on the RAID array being
654 reshaped.
655
656 .TP
657 .BR \-\-array-size= ", " \-Z
658 Set the size of the array which is seen by users of the device such as
659 filesystems. This can be less that the real size, but never greater.
660 The size set this way does not persist across restarts of the array.
661
662 This is most useful when reducing the number of devices in a RAID5 or
663 RAID6. Such arrays require the array-size to be reduced before a
664 reshape can be performed that reduces the real size.
665
666 A value of
667 .B max
668 restores the apparent size of the array to be whatever the real
669 amount of available space is.
670
671 .TP
672 .BR \-N ", " \-\-name=
673 Set a
674 .B name
675 for the array. This is currently only effective when creating an
676 array with a version-1 superblock, or an array in a DDF container.
677 The name is a simple textual string that can be used to identify array
678 components when assembling. If name is needed but not specified, it
679 is taken from the basename of the device that is being created.
680 e.g. when creating
681 .I /dev/md/home
682 the
683 .B name
684 will default to
685 .IR home .
686
687 .TP
688 .BR \-R ", " \-\-run
689 Insist that
690 .I mdadm
691 run the array, even if some of the components
692 appear to be active in another array or filesystem. Normally
693 .I mdadm
694 will ask for confirmation before including such components in an
695 array. This option causes that question to be suppressed.
696
697 .TP
698 .BR \-f ", " \-\-force
699 Insist that
700 .I mdadm
701 accept the geometry and layout specified without question. Normally
702 .I mdadm
703 will not allow creation of an array with only one device, and will try
704 to create a RAID5 array with one missing drive (as this makes the
705 initial resync work faster). With
706 .BR \-\-force ,
707 .I mdadm
708 will not try to be so clever.
709
710 .TP
711 .BR \-a ", " "\-\-auto{=yes,md,mdp,part,p}{NN}"
712 Instruct mdadm how to create the device file if needed, possibly allocating
713 an unused minor number. "md" causes a non-partitionable array
714 to be used (though since Linux 2.6.28, these array devices are in fact
715 partitionable). "mdp", "part" or "p" causes a partitionable array (2.6 and
716 later) to be used. "yes" requires the named md device to have
717 a 'standard' format, and the type and minor number will be determined
718 from this. With mdadm 3.0, device creation is normally left up to
719 .I udev
720 so this option is unlikely to be needed.
721 See DEVICE NAMES below.
722
723 The argument can also come immediately after
724 "\-a". e.g. "\-ap".
725
726 If
727 .B \-\-auto
728 is not given on the command line or in the config file, then
729 the default will be
730 .BR \-\-auto=yes .
731
732 If
733 .B \-\-scan
734 is also given, then any
735 .I auto=
736 entries in the config file will override the
737 .B \-\-auto
738 instruction given on the command line.
739
740 For partitionable arrays,
741 .I mdadm
742 will create the device file for the whole array and for the first 4
743 partitions. A different number of partitions can be specified at the
744 end of this option (e.g.
745 .BR \-\-auto=p7 ).
746 If the device name ends with a digit, the partition names add a 'p',
747 and a number, e.g.
748 .IR /dev/md/home1p3 .
749 If there is no trailing digit, then the partition names just have a
750 number added, e.g.
751 .IR /dev/md/scratch3 .
752
753 If the md device name is in a 'standard' format as described in DEVICE
754 NAMES, then it will be created, if necessary, with the appropriate
755 device number based on that name. If the device name is not in one of these
756 formats, then a unused device number will be allocated. The device
757 number will be considered unused if there is no active array for that
758 number, and there is no entry in /dev for that number and with a
759 non-standard name. Names that are not in 'standard' format are only
760 allowed in "/dev/md/".
761
762 .ig XX
763 .\".TP
764 .\".BR \-\-symlink = no
765 .\"Normally when
766 .\".B \-\-auto
767 .\"causes
768 .\".I mdadm
769 .\"to create devices in
770 .\".B /dev/md/
771 .\"it will also create symlinks from
772 .\".B /dev/
773 .\"with names starting with
774 .\".B md
775 .\"or
776 .\".BR md_ .
777 .\"Use
778 .\".B \-\-symlink=no
779 .\"to suppress this, or
780 .\".B \-\-symlink=yes
781 .\"to enforce this even if it is suppressing
782 .\".IR mdadm.conf .
783 .\"
784 .XX
785
786 .SH For assemble:
787
788 .TP
789 .BR \-u ", " \-\-uuid=
790 uuid of array to assemble. Devices which don't have this uuid are
791 excluded
792
793 .TP
794 .BR \-m ", " \-\-super\-minor=
795 Minor number of device that array was created for. Devices which
796 don't have this minor number are excluded. If you create an array as
797 /dev/md1, then all superblocks will contain the minor number 1, even if
798 the array is later assembled as /dev/md2.
799
800 Giving the literal word "dev" for
801 .B \-\-super\-minor
802 will cause
803 .I mdadm
804 to use the minor number of the md device that is being assembled.
805 e.g. when assembling
806 .BR /dev/md0 ,
807 .B \-\-super\-minor=dev
808 will look for super blocks with a minor number of 0.
809
810 .B \-\-super\-minor
811 is only relevant for v0.90 metadata, and should not normally be used.
812 Using
813 .B \-\-uuid
814 is much safer.
815
816 .TP
817 .BR \-N ", " \-\-name=
818 Specify the name of the array to assemble. This must be the name
819 that was specified when creating the array. It must either match
820 the name stored in the superblock exactly, or it must match
821 with the current
822 .I homehost
823 prefixed to the start of the given name.
824
825 .TP
826 .BR \-f ", " \-\-force
827 Assemble the array even if the metadata on some devices appears to be
828 out-of-date. If
829 .I mdadm
830 cannot find enough working devices to start the array, but can find
831 some devices that are recorded as having failed, then it will mark
832 those devices as working so that the array can be started.
833 An array which requires
834 .B \-\-force
835 to be started may contain data corruption. Use it carefully.
836
837 .TP
838 .BR \-R ", " \-\-run
839 Attempt to start the array even if fewer drives were given than were
840 present last time the array was active. Normally if not all the
841 expected drives are found and
842 .B \-\-scan
843 is not used, then the array will be assembled but not started.
844 With
845 .B \-\-run
846 an attempt will be made to start it anyway.
847
848 .TP
849 .B \-\-no\-degraded
850 This is the reverse of
851 .B \-\-run
852 in that it inhibits the startup of array unless all expected drives
853 are present. This is only needed with
854 .B \-\-scan,
855 and can be used if the physical connections to devices are
856 not as reliable as you would like.
857
858 .TP
859 .BR \-a ", " "\-\-auto{=no,yes,md,mdp,part}"
860 See this option under Create and Build options.
861
862 .TP
863 .BR \-b ", " \-\-bitmap=
864 Specify the bitmap file that was given when the array was created. If
865 an array has an
866 .B internal
867 bitmap, there is no need to specify this when assembling the array.
868
869 .TP
870 .BR \-\-backup\-file=
871 If
872 .B \-\-backup\-file
873 was used to grow the number of raid-devices in a RAID5, and the system
874 crashed during the critical section, then the same
875 .B \-\-backup\-file
876 must be presented to
877 .B \-\-assemble
878 to allow possibly corrupted data to be restored.
879
880 .TP
881 .BR \-U ", " \-\-update=
882 Update the superblock on each device while assembling the array. The
883 argument given to this flag can be one of
884 .BR sparc2.2 ,
885 .BR summaries ,
886 .BR uuid ,
887 .BR name ,
888 .BR homehost ,
889 .BR resync ,
890 .BR byteorder ,
891 .BR devicesize ,
892 or
893 .BR super\-minor .
894
895 The
896 .B sparc2.2
897 option will adjust the superblock of an array what was created on a Sparc
898 machine running a patched 2.2 Linux kernel. This kernel got the
899 alignment of part of the superblock wrong. You can use the
900 .B "\-\-examine \-\-sparc2.2"
901 option to
902 .I mdadm
903 to see what effect this would have.
904
905 The
906 .B super\-minor
907 option will update the
908 .B "preferred minor"
909 field on each superblock to match the minor number of the array being
910 assembled.
911 This can be useful if
912 .B \-\-examine
913 reports a different "Preferred Minor" to
914 .BR \-\-detail .
915 In some cases this update will be performed automatically
916 by the kernel driver. In particular the update happens automatically
917 at the first write to an array with redundancy (RAID level 1 or
918 greater) on a 2.6 (or later) kernel.
919
920 The
921 .B uuid
922 option will change the uuid of the array. If a UUID is given with the
923 .B \-\-uuid
924 option that UUID will be used as a new UUID and will
925 .B NOT
926 be used to help identify the devices in the array.
927 If no
928 .B \-\-uuid
929 is given, a random UUID is chosen.
930
931 The
932 .B name
933 option will change the
934 .I name
935 of the array as stored in the superblock. This is only supported for
936 version-1 superblocks.
937
938 The
939 .B homehost
940 option will change the
941 .I homehost
942 as recorded in the superblock. For version-0 superblocks, this is the
943 same as updating the UUID.
944 For version-1 superblocks, this involves updating the name.
945
946 The
947 .B resync
948 option will cause the array to be marked
949 .I dirty
950 meaning that any redundancy in the array (e.g. parity for RAID5,
951 copies for RAID1) may be incorrect. This will cause the RAID system
952 to perform a "resync" pass to make sure that all redundant information
953 is correct.
954
955 The
956 .B byteorder
957 option allows arrays to be moved between machines with different
958 byte-order.
959 When assembling such an array for the first time after a move, giving
960 .B "\-\-update=byteorder"
961 will cause
962 .I mdadm
963 to expect superblocks to have their byteorder reversed, and will
964 correct that order before assembling the array. This is only valid
965 with original (Version 0.90) superblocks.
966
967 The
968 .B summaries
969 option will correct the summaries in the superblock. That is the
970 counts of total, working, active, failed, and spare devices.
971
972 The
973 .B devicesize
974 will rarely be of use. It applies to version 1.1 and 1.2 metadata
975 only (where the metadata is at the start of the device) and is only
976 useful when the component device has changed size (typically become
977 larger). The version 1 metadata records the amount of the device that
978 can be used to store data, so if a device in a version 1.1 or 1.2
979 array becomes larger, the metadata will still be visible, but the
980 extra space will not. In this case it might be useful to assemble the
981 array with
982 .BR \-\-update=devicesize .
983 This will cause
984 .I mdadm
985 to determine the maximum usable amount of space on each device and
986 update the relevant field in the metadata.
987
988 .ig
989 .TP
990 .B \-\-auto\-update\-homehost
991 This flag is only meaningful with auto-assembly (see discussion below).
992 In that situation, if no suitable arrays are found for this homehost,
993 .I mdadm
994 will rescan for any arrays at all and will assemble them and update the
995 homehost to match the current host.
996 ..
997
998 .SH For Manage mode:
999
1000 .TP
1001 .BR \-a ", " \-\-add
1002 hot-add listed devices. For arrays with redundancy, the listed
1003 devices become available as spares. If the array is degraded, it will
1004 immediately start recovering data on to one of these spares.
1005
1006 .TP
1007 .BR \-\-re\-add
1008 re-add a device that was recently removed from an array. This is only
1009 needed for arrays that have be built (i.e. with
1010 .BR --build ).
1011 For created arrays, devices are always re-added if that is possible.
1012 When re-adding a device, if nothing has changed on the array since the
1013 device was removed, no recovery is performed. Also, if the array has
1014 a write-intent bitmap, then the recovery performed after a re-add will
1015 be limited to those blocks which, according to the bitmap, might have
1016 changed since the device was removed.
1017
1018 .TP
1019 .BR \-r ", " \-\-remove
1020 remove listed devices. They must not be active. i.e. they should
1021 be failed or spare devices. As well as the name of a device file
1022 (e.g.
1023 .BR /dev/sda1 )
1024 the words
1025 .B failed
1026 and
1027 .B detached
1028 can be given to
1029 .BR \-\-remove .
1030 The first causes all failed device to be removed. The second causes
1031 any device which is no longer connected to the system (i.e an 'open'
1032 returns
1033 .BR ENXIO )
1034 to be removed. This will only succeed for devices that are spares or
1035 have already been marked as failed.
1036
1037 .TP
1038 .BR \-f ", " \-\-fail
1039 mark listed devices as faulty.
1040 As well as the name of a device file, the word
1041 .B detached
1042 can be given. This will cause any device that has been detached from
1043 the system to be marked as failed. It can then be removed.
1044
1045 .TP
1046 .BR \-\-set\-faulty
1047 same as
1048 .BR \-\-fail .
1049
1050 .TP
1051 .BR \-\-write\-mostly
1052 Subsequent devices that are added or re-added will have the 'write-mostly'
1053 flag set. This is only valid for RAID1 and means that the 'md' driver
1054 will avoid reading from these devices if possible.
1055 .TP
1056 .BR \-\-readwrite
1057 Subsequent devices that are added or re-added will have the 'write-mostly'
1058 flag cleared.
1059
1060 .P
1061 Each of these options requires that the first device listed is the array
1062 to be acted upon, and the remainder are component devices to be added,
1063 removed, marked as faulty, etc. Several different operations can be
1064 specified for different devices, e.g.
1065 .in +5
1066 mdadm /dev/md0 \-\-add /dev/sda1 \-\-fail /dev/sdb1 \-\-remove /dev/sdb1
1067 .in -5
1068 Each operation applies to all devices listed until the next
1069 operation.
1070
1071 If an array is using a write-intent bitmap, then devices which have
1072 been removed can be re-added in a way that avoids a full
1073 reconstruction but instead just updates the blocks that have changed
1074 since the device was removed. For arrays with persistent metadata
1075 (superblocks) this is done automatically. For arrays created with
1076 .B \-\-build
1077 mdadm needs to be told that this device we removed recently with
1078 .BR \-\-re\-add .
1079
1080 Devices can only be removed from an array if they are not in active
1081 use, i.e. that must be spares or failed devices. To remove an active
1082 device, it must first be marked as
1083 .B faulty.
1084
1085 .SH For Misc mode:
1086
1087 .TP
1088 .BR \-Q ", " \-\-query
1089 Examine a device to see
1090 (1) if it is an md device and (2) if it is a component of an md
1091 array.
1092 Information about what is discovered is presented.
1093
1094 .TP
1095 .BR \-D ", " \-\-detail
1096 Print details of one or more md devices.
1097
1098 .TP
1099 .BR \-\-detail\-platform
1100 Print details of the platform's RAID capabilities (firmware / hardware
1101 topology) for a given metadata format.
1102
1103 .TP
1104 .BR \-Y ", " \-\-export
1105 When used with
1106 .B \-\-detail
1107 or
1108 .BR \-\-examine ,
1109 output will be formatted as
1110 .B key=value
1111 pairs for easy import into the environment.
1112
1113 .TP
1114 .BR \-E ", " \-\-examine
1115 Print contents of the metadata stored on the named device(s).
1116 Note the contrast between
1117 .B \-\-examine
1118 and
1119 .BR \-\-detail .
1120 .B \-\-examine
1121 applies to devices which are components of an array, while
1122 .B \-\-detail
1123 applies to a whole array which is currently active.
1124 .TP
1125 .B \-\-sparc2.2
1126 If an array was created on a SPARC machine with a 2.2 Linux kernel
1127 patched with RAID support, the superblock will have been created
1128 incorrectly, or at least incompatibly with 2.4 and later kernels.
1129 Using the
1130 .B \-\-sparc2.2
1131 flag with
1132 .B \-\-examine
1133 will fix the superblock before displaying it. If this appears to do
1134 the right thing, then the array can be successfully assembled using
1135 .BR "\-\-assemble \-\-update=sparc2.2" .
1136
1137 .TP
1138 .BR \-X ", " \-\-examine\-bitmap
1139 Report information about a bitmap file.
1140 The argument is either an external bitmap file or an array component
1141 in case of an internal bitmap. Note that running this on an array
1142 device (e.g.
1143 .BR /dev/md0 )
1144 does not report the bitmap for that array.
1145
1146 .TP
1147 .BR \-R ", " \-\-run
1148 start a partially assembled array. If
1149 .B \-\-assemble
1150 did not find enough devices to fully start the array, it might leaving
1151 it partially assembled. If you wish, you can then use
1152 .B \-\-run
1153 to start the array in degraded mode.
1154
1155 .TP
1156 .BR \-S ", " \-\-stop
1157 deactivate array, releasing all resources.
1158
1159 .TP
1160 .BR \-o ", " \-\-readonly
1161 mark array as readonly.
1162
1163 .TP
1164 .BR \-w ", " \-\-readwrite
1165 mark array as readwrite.
1166
1167 .TP
1168 .B \-\-zero\-superblock
1169 If the device contains a valid md superblock, the block is
1170 overwritten with zeros. With
1171 .B \-\-force
1172 the block where the superblock would be is overwritten even if it
1173 doesn't appear to be valid.
1174
1175 .TP
1176 .B \-\-kill\-subarray=
1177 If the device is a container and the argument to \-\-kill\-subarray
1178 specifies an inactive subarray in the container, then the subarray is
1179 deleted. Deleting all subarrays will leave an 'empty-container' or
1180 spare superblock on the drives. See \-\-zero\-superblock for completely
1181 removing a superblock. Note that some formats depend on the subarray
1182 index for generating a UUID, this command will fail if it would change
1183 the UUID of an active subarray.
1184
1185 .TP
1186 .B \-\-update\-subarray=
1187 If the device is a container and the argument to \-\-update\-subarray
1188 specifies a subarray in the container, then attempt to update the given
1189 superblock field in the subarray. See below in
1190 .B MISC MODE
1191 for details.
1192
1193 .TP
1194 .BR \-t ", " \-\-test
1195 When used with
1196 .BR \-\-detail ,
1197 the exit status of
1198 .I mdadm
1199 is set to reflect the status of the device. See below in
1200 .B MISC MODE
1201 for details.
1202
1203 .TP
1204 .BR \-W ", " \-\-wait
1205 For each md device given, wait for any resync, recovery, or reshape
1206 activity to finish before returning.
1207 .I mdadm
1208 will return with success if it actually waited for every device
1209 listed, otherwise it will return failure.
1210
1211 .TP
1212 .BR \-\-wait\-clean
1213 For each md device given, or each device in /proc/mdstat if
1214 .B \-\-scan
1215 is given, arrange for the array to be marked clean as soon as possible.
1216 .I mdadm
1217 will return with success if the array uses external metadata and we
1218 successfully waited. For native arrays this returns immediately as the
1219 kernel handles dirty-clean transitions at shutdown. No action is taken
1220 if safe-mode handling is disabled.
1221
1222 .SH For Incremental Assembly mode:
1223 .TP
1224 .BR \-\-rebuild\-map ", " \-r
1225 Rebuild the map file
1226 .RB ( /var/run/mdadm/map )
1227 that
1228 .I mdadm
1229 uses to help track which arrays are currently being assembled.
1230
1231 .TP
1232 .BR \-\-run ", " \-R
1233 Run any array assembled as soon as a minimal number of devices are
1234 available, rather than waiting until all expected devices are present.
1235
1236 .TP
1237 .B \-\-no\-degraded
1238 This allows the hot-plug system to prevent arrays from running when it knows
1239 that more disks may arrive later in the discovery process.
1240
1241 .TP
1242 .BR \-\-scan ", " \-s
1243 Only meaningful with
1244 .B \-R
1245 this will scan the
1246 .B map
1247 file for arrays that are being incrementally assembled and will try to
1248 start any that are not already started. If any such array is listed
1249 in
1250 .B mdadm.conf
1251 as requiring an external bitmap, that bitmap will be attached first.
1252
1253 .SH For Monitor mode:
1254 .TP
1255 .BR \-m ", " \-\-mail
1256 Give a mail address to send alerts to.
1257
1258 .TP
1259 .BR \-p ", " \-\-program ", " \-\-alert
1260 Give a program to be run whenever an event is detected.
1261
1262 .TP
1263 .BR \-y ", " \-\-syslog
1264 Cause all events to be reported through 'syslog'. The messages have
1265 facility of 'daemon' and varying priorities.
1266
1267 .TP
1268 .BR \-d ", " \-\-delay
1269 Give a delay in seconds.
1270 .I mdadm
1271 polls the md arrays and then waits this many seconds before polling
1272 again. The default is 60 seconds. Since 2.6.16, there is no need to
1273 reduce this as the kernel alerts
1274 .I mdadm
1275 immediately when there is any change.
1276
1277 .TP
1278 .BR \-r ", " \-\-increment
1279 Give a percentage increment.
1280 .I mdadm
1281 will generate RebuildNN events with the given percentage increment.
1282
1283 .TP
1284 .BR \-f ", " \-\-daemonise
1285 Tell
1286 .I mdadm
1287 to run as a background daemon if it decides to monitor anything. This
1288 causes it to fork and run in the child, and to disconnect from the
1289 terminal. The process id of the child is written to stdout.
1290 This is useful with
1291 .B \-\-scan
1292 which will only continue monitoring if a mail address or alert program
1293 is found in the config file.
1294
1295 .TP
1296 .BR \-i ", " \-\-pid\-file
1297 When
1298 .I mdadm
1299 is running in daemon mode, write the pid of the daemon process to
1300 the specified file, instead of printing it on standard output.
1301
1302 .TP
1303 .BR \-1 ", " \-\-oneshot
1304 Check arrays only once. This will generate
1305 .B NewArray
1306 events and more significantly
1307 .B DegradedArray
1308 and
1309 .B SparesMissing
1310 events. Running
1311 .in +5
1312 .B " mdadm \-\-monitor \-\-scan \-1"
1313 .in -5
1314 from a cron script will ensure regular notification of any degraded arrays.
1315
1316 .TP
1317 .BR \-t ", " \-\-test
1318 Generate a
1319 .B TestMessage
1320 alert for every array found at startup. This alert gets mailed and
1321 passed to the alert program. This can be used for testing that alert
1322 message do get through successfully.
1323
1324 .SH ASSEMBLE MODE
1325
1326 .HP 12
1327 Usage:
1328 .B mdadm \-\-assemble
1329 .I md-device options-and-component-devices...
1330 .HP 12
1331 Usage:
1332 .B mdadm \-\-assemble \-\-scan
1333 .I md-devices-and-options...
1334 .HP 12
1335 Usage:
1336 .B mdadm \-\-assemble \-\-scan
1337 .I options...
1338
1339 .PP
1340 This usage assembles one or more RAID arrays from pre-existing components.
1341 For each array, mdadm needs to know the md device, the identity of the
1342 array, and a number of component-devices. These can be found in a number of ways.
1343
1344 In the first usage example (without the
1345 .BR \-\-scan )
1346 the first device given is the md device.
1347 In the second usage example, all devices listed are treated as md
1348 devices and assembly is attempted.
1349 In the third (where no devices are listed) all md devices that are
1350 listed in the configuration file are assembled. If not arrays are
1351 described by the configuration file, then any arrays that
1352 can be found on unused devices will be assembled.
1353
1354 If precisely one device is listed, but
1355 .B \-\-scan
1356 is not given, then
1357 .I mdadm
1358 acts as though
1359 .B \-\-scan
1360 was given and identity information is extracted from the configuration file.
1361
1362 The identity can be given with the
1363 .B \-\-uuid
1364 option, the
1365 .B \-\-name
1366 option, or the
1367 .B \-\-super\-minor
1368 option, will be taken from the md-device record in the config file, or
1369 will be taken from the super block of the first component-device
1370 listed on the command line.
1371
1372 Devices can be given on the
1373 .B \-\-assemble
1374 command line or in the config file. Only devices which have an md
1375 superblock which contains the right identity will be considered for
1376 any array.
1377
1378 The config file is only used if explicitly named with
1379 .B \-\-config
1380 or requested with (a possibly implicit)
1381 .BR \-\-scan .
1382 In the later case,
1383 .B /etc/mdadm.conf
1384 or
1385 .B /etc/mdadm/mdadm.conf
1386 is used.
1387
1388 If
1389 .B \-\-scan
1390 is not given, then the config file will only be used to find the
1391 identity of md arrays.
1392
1393 Normally the array will be started after it is assembled. However if
1394 .B \-\-scan
1395 is not given and not all expected drives were listed, then the array
1396 is not started (to guard against usage errors). To insist that the
1397 array be started in this case (as may work for RAID1, 4, 5, 6, or 10),
1398 give the
1399 .B \-\-run
1400 flag.
1401
1402 If
1403 .I udev
1404 is active,
1405 .I mdadm
1406 does not create any entries in
1407 .B /dev
1408 but leaves that to
1409 .IR udev .
1410 It does record information in
1411 .B /var/run/mdadm/map
1412 which will allow
1413 .I udev
1414 to choose the correct name.
1415
1416 If
1417 .I mdadm
1418 detects that udev is not configured, it will create the devices in
1419 .B /dev
1420 itself.
1421
1422 In Linux kernels prior to version 2.6.28 there were two distinctly
1423 different types of md devices that could be created: one that could be
1424 partitioned using standard partitioning tools and one that could not.
1425 Since 2.6.28 that distinction is no longer relevant as both type of
1426 devices can be partitioned.
1427 .I mdadm
1428 will normally create the type that originally could not be partitioned
1429 as it has a well defined major number (9).
1430
1431 Prior to 2.6.28, it is important that mdadm chooses the correct type
1432 of array device to use. This can be controlled with the
1433 .B \-\-auto
1434 option. In particular, a value of "mdp" or "part" or "p" tells mdadm
1435 to use a partitionable device rather than the default.
1436
1437 In the no-udev case, the value given to
1438 .B \-\-auto
1439 can be suffixed by a number. This tells
1440 .I mdadm
1441 to create that number of partition devices rather than the default of 4.
1442
1443 The value given to
1444 .B \-\-auto
1445 can also be given in the configuration file as a word starting
1446 .B auto=
1447 on the ARRAY line for the relevant array.
1448
1449 .SS Auto Assembly
1450 When
1451 .B \-\-assemble
1452 is used with
1453 .B \-\-scan
1454 and no devices are listed,
1455 .I mdadm
1456 will first attempt to assemble all the arrays listed in the config
1457 file.
1458
1459 In no array at listed in the config (other than those marked
1460 .BR <ignore> )
1461 it will look through the available devices for possible arrays and
1462 will try to assemble anything that it finds. Arrays which are tagged
1463 as belonging to the given homehost will be assembled and started
1464 normally. Arrays which do not obviously belong to this host are given
1465 names that are expected not to conflict with anything local, and are
1466 started "read-auto" so that nothing is written to any device until the
1467 array is written to. i.e. automatic resync etc is delayed.
1468
1469 If
1470 .I mdadm
1471 finds a consistent set of devices that look like they should comprise
1472 an array, and if the superblock is tagged as belonging to the given
1473 home host, it will automatically choose a device name and try to
1474 assemble the array. If the array uses version-0.90 metadata, then the
1475 .B minor
1476 number as recorded in the superblock is used to create a name in
1477 .B /dev/md/
1478 so for example
1479 .BR /dev/md/3 .
1480 If the array uses version-1 metadata, then the
1481 .B name
1482 from the superblock is used to similarly create a name in
1483 .B /dev/md/
1484 (the name will have any 'host' prefix stripped first).
1485
1486 This behaviour can be modified by the
1487 .I AUTO
1488 line in the
1489 .I mdadm.conf
1490 configuration file. This line can indicate that specific metadata
1491 type should, or should not, be automatically assembled. If an array
1492 is found which is not listed in
1493 .I mdadm.conf
1494 and has a metadata format that is denied by the
1495 .I AUTO
1496 line, then it will not be assembled.
1497 The
1498 .I AUTO
1499 line can also request that all arrays identified as being for this
1500 homehost should be assembled regardless of their metadata type.
1501 See
1502 .IR mdadm.conf (5)
1503 for further details.
1504
1505 .ig
1506 If
1507 .I mdadm
1508 cannot find any array for the given host at all, and if
1509 .B \-\-auto\-update\-homehost
1510 is given, then
1511 .I mdadm
1512 will search again for any array (not just an array created for this
1513 host) and will assemble each assuming
1514 .BR \-\-update=homehost .
1515 This will change the host tag in the superblock so that on the next run,
1516 these arrays will be found without the second pass. The intention of
1517 this feature is to support transitioning a set of md arrays to using
1518 homehost tagging.
1519
1520 The reason for requiring arrays to be tagged with the homehost for
1521 auto assembly is to guard against problems that can arise when moving
1522 devices from one host to another.
1523 ..
1524
1525 .SH BUILD MODE
1526
1527 .HP 12
1528 Usage:
1529 .B mdadm \-\-build
1530 .I md-device
1531 .BI \-\-chunk= X
1532 .BI \-\-level= Y
1533 .BI \-\-raid\-devices= Z
1534 .I devices
1535
1536 .PP
1537 This usage is similar to
1538 .BR \-\-create .
1539 The difference is that it creates an array without a superblock. With
1540 these arrays there is no difference between initially creating the array and
1541 subsequently assembling the array, except that hopefully there is useful
1542 data there in the second case.
1543
1544 The level may raid0, linear, raid1, raid10, multipath, or faulty, or
1545 one of their synonyms. All devices must be listed and the array will
1546 be started once complete. It will often be appropriate to use
1547 .B \-\-assume\-clean
1548 with levels raid1 or raid10.
1549
1550 .SH CREATE MODE
1551
1552 .HP 12
1553 Usage:
1554 .B mdadm \-\-create
1555 .I md-device
1556 .BI \-\-chunk= X
1557 .BI \-\-level= Y
1558 .br
1559 .BI \-\-raid\-devices= Z
1560 .I devices
1561
1562 .PP
1563 This usage will initialise a new md array, associate some devices with
1564 it, and activate the array.
1565
1566 The named device will normally not exist when
1567 .I "mdadm \-\-create"
1568 is run, but will be created by
1569 .I udev
1570 once the array becomes active.
1571
1572 As devices are added, they are checked to see if they contain RAID
1573 superblocks or filesystems. They are also checked to see if the variance in
1574 device size exceeds 1%.
1575
1576 If any discrepancy is found, the array will not automatically be run, though
1577 the presence of a
1578 .B \-\-run
1579 can override this caution.
1580
1581 To create a "degraded" array in which some devices are missing, simply
1582 give the word "\fBmissing\fP"
1583 in place of a device name. This will cause
1584 .I mdadm
1585 to leave the corresponding slot in the array empty.
1586 For a RAID4 or RAID5 array at most one slot can be
1587 "\fBmissing\fP"; for a RAID6 array at most two slots.
1588 For a RAID1 array, only one real device needs to be given. All of the
1589 others can be
1590 "\fBmissing\fP".
1591
1592 When creating a RAID5 array,
1593 .I mdadm
1594 will automatically create a degraded array with an extra spare drive.
1595 This is because building the spare into a degraded array is in general
1596 faster than resyncing the parity on a non-degraded, but not clean,
1597 array. This feature can be overridden with the
1598 .B \-\-force
1599 option.
1600
1601 When creating an array with version-1 metadata a name for the array is
1602 required.
1603 If this is not given with the
1604 .B \-\-name
1605 option,
1606 .I mdadm
1607 will choose a name based on the last component of the name of the
1608 device being created. So if
1609 .B /dev/md3
1610 is being created, then the name
1611 .B 3
1612 will be chosen.
1613 If
1614 .B /dev/md/home
1615 is being created, then the name
1616 .B home
1617 will be used.
1618
1619 When creating a partition based array, using
1620 .I mdadm
1621 with version-1.x metadata, the partition type should be set to
1622 .B 0xDA
1623 (non fs-data). This type selection allows for greater precision since
1624 using any other [RAID auto-detect (0xFD) or a GNU/Linux partition (0x83)],
1625 might create problems in the event of array recovery through a live cdrom.
1626
1627 A new array will normally get a randomly assigned 128bit UUID which is
1628 very likely to be unique. If you have a specific need, you can choose
1629 a UUID for the array by giving the
1630 .B \-\-uuid=
1631 option. Be warned that creating two arrays with the same UUID is a
1632 recipe for disaster. Also, using
1633 .B \-\-uuid=
1634 when creating a v0.90 array will silently override any
1635 .B \-\-homehost=
1636 setting.
1637 .\"If the
1638 .\".B \-\-size
1639 .\"option is given, it is not necessary to list any component-devices in this command.
1640 .\"They can be added later, before a
1641 .\".B \-\-run.
1642 .\"If no
1643 .\".B \-\-size
1644 .\"is given, the apparent size of the smallest drive given is used.
1645
1646 When creating an array within a
1647 .B CONTAINER
1648 .I mdadm
1649 can be given either the list of devices to use, or simply the name of
1650 the container. The former case gives control over which devices in
1651 the container will be used for the array. The latter case allows
1652 .I mdadm
1653 to automatically choose which devices to use based on how much spare
1654 space is available.
1655
1656 The General Management options that are valid with
1657 .B \-\-create
1658 are:
1659 .TP
1660 .B \-\-run
1661 insist on running the array even if some devices look like they might
1662 be in use.
1663
1664 .TP
1665 .B \-\-readonly
1666 start the array readonly \(em not supported yet.
1667
1668 .SH MANAGE MODE
1669 .HP 12
1670 Usage:
1671 .B mdadm
1672 .I device
1673 .I options... devices...
1674 .PP
1675
1676 This usage will allow individual devices in an array to be failed,
1677 removed or added. It is possible to perform multiple operations with
1678 on command. For example:
1679 .br
1680 .B " mdadm /dev/md0 \-f /dev/hda1 \-r /dev/hda1 \-a /dev/hda1"
1681 .br
1682 will firstly mark
1683 .B /dev/hda1
1684 as faulty in
1685 .B /dev/md0
1686 and will then remove it from the array and finally add it back
1687 in as a spare. However only one md array can be affected by a single
1688 command.
1689
1690 When a device is added to an active array, mdadm checks to see if it
1691 has metadata on it which suggests that it was recently a member of the
1692 array. If it does, it tried to "re-add" the device. If there have
1693 been no changes since the device was removed, or if the array has a
1694 write-intent bitmap which has recorded whatever changes there were,
1695 then the device will immediately become a full member of the array and
1696 those differences recorded in the bitmap will be resolved.
1697
1698 .SH MISC MODE
1699 .HP 12
1700 Usage:
1701 .B mdadm
1702 .I options ...
1703 .I devices ...
1704 .PP
1705
1706 MISC mode includes a number of distinct operations that
1707 operate on distinct devices. The operations are:
1708 .TP
1709 .B \-\-query
1710 The device is examined to see if it is
1711 (1) an active md array, or
1712 (2) a component of an md array.
1713 The information discovered is reported.
1714
1715 .TP
1716 .B \-\-detail
1717 The device should be an active md device.
1718 .B mdadm
1719 will display a detailed description of the array.
1720 .B \-\-brief
1721 or
1722 .B \-\-scan
1723 will cause the output to be less detailed and the format to be
1724 suitable for inclusion in
1725 .BR /etc/mdadm.conf .
1726 The exit status of
1727 .I mdadm
1728 will normally be 0 unless
1729 .I mdadm
1730 failed to get useful information about the device(s); however, if the
1731 .B \-\-test
1732 option is given, then the exit status will be:
1733 .RS
1734 .TP
1735 0
1736 The array is functioning normally.
1737 .TP
1738 1
1739 The array has at least one failed device.
1740 .TP
1741 2
1742 The array has multiple failed devices such that it is unusable.
1743 .TP
1744 4
1745 There was an error while trying to get information about the device.
1746 .RE
1747
1748 .TP
1749 .B \-\-detail\-platform
1750 Print detail of the platform's RAID capabilities (firmware / hardware
1751 topology). If the metadata is specified with
1752 .B \-e
1753 or
1754 .B \-\-metadata=
1755 then the return status will be:
1756 .RS
1757 .TP
1758 0
1759 metadata successfully enumerated its platform components on this system
1760 .TP
1761 1
1762 metadata is platform independent
1763 .TP
1764 2
1765 metadata failed to find its platform components on this system
1766 .RE
1767
1768 .TP
1769 .B \-\-update\-subarray=
1770 If the device is a container and the argument to \-\-update\-subarray
1771 specifies a subarray in the container, then attempt to update the given
1772 superblock field in the subarray. Similar to updating an array in
1773 "assemble" mode, the field to update is selected by
1774 .B \-U
1775 or
1776 .B \-\-update=
1777 option. Currently only
1778 .B name
1779 is supported.
1780
1781 The
1782 .B name
1783 option updates the subarray name in the metadata, it may not affect the
1784 device node name or the device node symlink until the subarray is
1785 re\-assembled. If updating
1786 .B name
1787 would change the UUID of an active subarray this operation is blocked,
1788 and the command will end in an error.
1789
1790 .TP
1791 .B \-\-examine
1792 The device should be a component of an md array.
1793 .I mdadm
1794 will read the md superblock of the device and display the contents.
1795 If
1796 .B \-\-brief
1797 or
1798 .B \-\-scan
1799 is given, then multiple devices that are components of the one array
1800 are grouped together and reported in a single entry suitable
1801 for inclusion in
1802 .BR /etc/mdadm.conf .
1803
1804 Having
1805 .B \-\-scan
1806 without listing any devices will cause all devices listed in the
1807 config file to be examined.
1808
1809 .TP
1810 .B \-\-stop
1811 The devices should be active md arrays which will be deactivated, as
1812 long as they are not currently in use.
1813
1814 .TP
1815 .B \-\-run
1816 This will fully activate a partially assembled md array.
1817
1818 .TP
1819 .B \-\-readonly
1820 This will mark an active array as read-only, providing that it is
1821 not currently being used.
1822
1823 .TP
1824 .B \-\-readwrite
1825 This will change a
1826 .B readonly
1827 array back to being read/write.
1828
1829 .TP
1830 .B \-\-scan
1831 For all operations except
1832 .BR \-\-examine ,
1833 .B \-\-scan
1834 will cause the operation to be applied to all arrays listed in
1835 .BR /proc/mdstat .
1836 For
1837 .BR \-\-examine,
1838 .B \-\-scan
1839 causes all devices listed in the config file to be examined.
1840
1841 .TP
1842 .BR \-b ", " \-\-brief
1843 Be less verbose. This is used with
1844 .B \-\-detail
1845 and
1846 .BR \-\-examine .
1847 Using
1848 .B \-\-brief
1849 with
1850 .B \-\-verbose
1851 gives an intermediate level of verbosity.
1852
1853 .SH MONITOR MODE
1854
1855 .HP 12
1856 Usage:
1857 .B mdadm \-\-monitor
1858 .I options... devices...
1859
1860 .PP
1861 This usage causes
1862 .I mdadm
1863 to periodically poll a number of md arrays and to report on any events
1864 noticed.
1865 .I mdadm
1866 will never exit once it decides that there are arrays to be checked,
1867 so it should normally be run in the background.
1868
1869 As well as reporting events,
1870 .I mdadm
1871 may move a spare drive from one array to another if they are in the
1872 same
1873 .B spare-group
1874 and if the destination array has a failed drive but no spares.
1875
1876 If any devices are listed on the command line,
1877 .I mdadm
1878 will only monitor those devices. Otherwise all arrays listed in the
1879 configuration file will be monitored. Further, if
1880 .B \-\-scan
1881 is given, then any other md devices that appear in
1882 .B /proc/mdstat
1883 will also be monitored.
1884
1885 The result of monitoring the arrays is the generation of events.
1886 These events are passed to a separate program (if specified) and may
1887 be mailed to a given E-mail address.
1888
1889 When passing events to a program, the program is run once for each event,
1890 and is given 2 or 3 command-line arguments: the first is the
1891 name of the event (see below), the second is the name of the
1892 md device which is affected, and the third is the name of a related
1893 device if relevant (such as a component device that has failed).
1894
1895 If
1896 .B \-\-scan
1897 is given, then a program or an E-mail address must be specified on the
1898 command line or in the config file. If neither are available, then
1899 .I mdadm
1900 will not monitor anything.
1901 Without
1902 .B \-\-scan,
1903 .I mdadm
1904 will continue monitoring as long as something was found to monitor. If
1905 no program or email is given, then each event is reported to
1906 .BR stdout .
1907
1908 The different events are:
1909
1910 .RS 4
1911 .TP
1912 .B DeviceDisappeared
1913 An md array which previously was configured appears to no longer be
1914 configured. (syslog priority: Critical)
1915
1916 If
1917 .I mdadm
1918 was told to monitor an array which is RAID0 or Linear, then it will
1919 report
1920 .B DeviceDisappeared
1921 with the extra information
1922 .BR Wrong-Level .
1923 This is because RAID0 and Linear do not support the device-failed,
1924 hot-spare and resync operations which are monitored.
1925
1926 .TP
1927 .B RebuildStarted
1928 An md array started reconstruction. (syslog priority: Warning)
1929
1930 .TP
1931 .BI Rebuild NN
1932 Where
1933 .I NN
1934 is a two-digit number (ie. 05, 48). This indicates that rebuild
1935 has passed that many percent of the total. The events are generated
1936 with fixed increment since 0. Increment size may be specified with
1937 a commandline option (default is 20). (syslog priority: Warning)
1938
1939 .TP
1940 .B RebuildFinished
1941 An md array that was rebuilding, isn't any more, either because it
1942 finished normally or was aborted. (syslog priority: Warning)
1943
1944 .TP
1945 .B Fail
1946 An active component device of an array has been marked as
1947 faulty. (syslog priority: Critical)
1948
1949 .TP
1950 .B FailSpare
1951 A spare component device which was being rebuilt to replace a faulty
1952 device has failed. (syslog priority: Critical)
1953
1954 .TP
1955 .B SpareActive
1956 A spare component device which was being rebuilt to replace a faulty
1957 device has been successfully rebuilt and has been made active.
1958 (syslog priority: Info)
1959
1960 .TP
1961 .B NewArray
1962 A new md array has been detected in the
1963 .B /proc/mdstat
1964 file. (syslog priority: Info)
1965
1966 .TP
1967 .B DegradedArray
1968 A newly noticed array appears to be degraded. This message is not
1969 generated when
1970 .I mdadm
1971 notices a drive failure which causes degradation, but only when
1972 .I mdadm
1973 notices that an array is degraded when it first sees the array.
1974 (syslog priority: Critical)
1975
1976 .TP
1977 .B MoveSpare
1978 A spare drive has been moved from one array in a
1979 .B spare-group
1980 to another to allow a failed drive to be replaced.
1981 (syslog priority: Info)
1982
1983 .TP
1984 .B SparesMissing
1985 If
1986 .I mdadm
1987 has been told, via the config file, that an array should have a certain
1988 number of spare devices, and
1989 .I mdadm
1990 detects that it has fewer than this number when it first sees the
1991 array, it will report a
1992 .B SparesMissing
1993 message.
1994 (syslog priority: Warning)
1995
1996 .TP
1997 .B TestMessage
1998 An array was found at startup, and the
1999 .B \-\-test
2000 flag was given.
2001 (syslog priority: Info)
2002 .RE
2003
2004 Only
2005 .B Fail,
2006 .B FailSpare,
2007 .B DegradedArray,
2008 .B SparesMissing
2009 and
2010 .B TestMessage
2011 cause Email to be sent. All events cause the program to be run.
2012 The program is run with two or three arguments: the event
2013 name, the array device and possibly a second device.
2014
2015 Each event has an associated array device (e.g.
2016 .BR /dev/md1 )
2017 and possibly a second device. For
2018 .BR Fail ,
2019 .BR FailSpare ,
2020 and
2021 .B SpareActive
2022 the second device is the relevant component device.
2023 For
2024 .B MoveSpare
2025 the second device is the array that the spare was moved from.
2026
2027 For
2028 .I mdadm
2029 to move spares from one array to another, the different arrays need to
2030 be labeled with the same
2031 .B spare-group
2032 in the configuration file. The
2033 .B spare-group
2034 name can be any string; it is only necessary that different spare
2035 groups use different names.
2036
2037 When
2038 .I mdadm
2039 detects that an array in a spare group has fewer active
2040 devices than necessary for the complete array, and has no spare
2041 devices, it will look for another array in the same spare group that
2042 has a full complement of working drive and a spare. It will then
2043 attempt to remove the spare from the second drive and add it to the
2044 first.
2045 If the removal succeeds but the adding fails, then it is added back to
2046 the original array.
2047
2048 .SH GROW MODE
2049 The GROW mode is used for changing the size or shape of an active
2050 array.
2051 For this to work, the kernel must support the necessary change.
2052 Various types of growth are being added during 2.6 development,
2053 including restructuring a RAID5 array to have more active devices.
2054
2055 Currently the only support available is to
2056 .IP \(bu 4
2057 change the "size" attribute
2058 for RAID1, RAID5 and RAID6.
2059 .IP \(bu 4
2060 increase or decrease the "raid\-devices" attribute of RAID1, RAID5,
2061 and RAID6.
2062 .IP \bu 4
2063 change the chunk-size and layout of RAID5 and RAID6.
2064 .IP \bu 4
2065 convert between RAID1 and RAID5, and between RAID5 and RAID6.
2066 .IP \(bu 4
2067 add a write-intent bitmap to any array which supports these bitmaps, or
2068 remove a write-intent bitmap from such an array.
2069 .PP
2070
2071 GROW mode is not currently supported for
2072 .B CONTAINERS
2073 or arrays inside containers.
2074
2075 .SS SIZE CHANGES
2076 Normally when an array is built the "size" it taken from the smallest
2077 of the drives. If all the small drives in an arrays are, one at a
2078 time, removed and replaced with larger drives, then you could have an
2079 array of large drives with only a small amount used. In this
2080 situation, changing the "size" with "GROW" mode will allow the extra
2081 space to start being used. If the size is increased in this way, a
2082 "resync" process will start to make sure the new parts of the array
2083 are synchronised.
2084
2085 Note that when an array changes size, any filesystem that may be
2086 stored in the array will not automatically grow to use the space. The
2087 filesystem will need to be explicitly told to use the extra space.
2088
2089 Also the size of an array cannot be changed while it has an active
2090 bitmap. If an array has a bitmap, it must be removed before the size
2091 can be changed. Once the change it complete a new bitmap can be created.
2092
2093 .SS RAID\-DEVICES CHANGES
2094
2095 A RAID1 array can work with any number of devices from 1 upwards
2096 (though 1 is not very useful). There may be times which you want to
2097 increase or decrease the number of active devices. Note that this is
2098 different to hot-add or hot-remove which changes the number of
2099 inactive devices.
2100
2101 When reducing the number of devices in a RAID1 array, the slots which
2102 are to be removed from the array must already be vacant. That is, the
2103 devices which were in those slots must be failed and removed.
2104
2105 When the number of devices is increased, any hot spares that are
2106 present will be activated immediately.
2107
2108 Changing the number of active devices in a RAID5 or RAID6 is much more
2109 effort. Every block in the array will need to be read and written
2110 back to a new location. From 2.6.17, the Linux Kernel is able to
2111 increase the number of devices in a RAID5 safely, including restarting
2112 an interrupted "reshape". From 2.6.31, the Linux Kernel is able to
2113 increase or decrease the number of devices in a RAID5 or RAID6.
2114
2115 When decreasing the number of devices, the size of the array will also
2116 decrease. If there was data in the array, it could get destroyed and
2117 this is not reversible. To help prevent accidents,
2118 .I mdadm
2119 requires that the size of the array be decreased first with
2120 .BR "mdadm --grow --array-size" .
2121 This is a reversible change which simply makes the end of the array
2122 inaccessible. The integrity of any data can then be checked before
2123 the non-reversible reduction in the number of devices is request.
2124
2125 When relocating the first few stripes on a RAID5, it is not possible
2126 to keep the data on disk completely consistent and crash-proof. To
2127 provide the required safety, mdadm disables writes to the array while
2128 this "critical section" is reshaped, and takes a backup of the data
2129 that is in that section. This backup is normally stored in any spare
2130 devices that the array has, however it can also be stored in a
2131 separate file specified with the
2132 .B \-\-backup\-file
2133 option. If this option is used, and the system does crash during the
2134 critical period, the same file must be passed to
2135 .B \-\-assemble
2136 to restore the backup and reassemble the array.
2137
2138 .SS LEVEL CHANGES
2139
2140 Changing the RAID level of any array happens instantaneously. However
2141 in the RAID to RAID6 case this requires a non-standard layout of the
2142 RAID6 data, and in the RAID6 to RAID5 case that non-standard layout is
2143 required before the change can be accomplish. So while the level
2144 change is instant, the accompanying layout change can take quite a
2145 long time.
2146
2147 .SS CHUNK-SIZE AND LAYOUT CHANGES
2148
2149 Changing the chunk-size of layout without also changing the number of
2150 devices as the same time will involve re-writing all blocks in-place.
2151 To ensure against data loss in the case of a crash, a
2152 .B --backup-file
2153 must be provided for these changes. Small sections of the array will
2154 be copied to the backup file while they are being rearranged.
2155
2156 If the reshape is interrupted for any reason, this backup file must be
2157 make available to
2158 .B "mdadm --assemble"
2159 so the array can be reassembled. Consequently the file cannot be
2160 stored on the device being reshaped.
2161
2162
2163 .SS BITMAP CHANGES
2164
2165 A write-intent bitmap can be added to, or removed from, an active
2166 array. Either internal bitmaps, or bitmaps stored in a separate file,
2167 can be added. Note that if you add a bitmap stored in a file which is
2168 in a filesystem that is on the RAID array being affected, the system
2169 will deadlock. The bitmap must be on a separate filesystem.
2170
2171 .SH INCREMENTAL MODE
2172
2173 .HP 12
2174 Usage:
2175 .B mdadm \-\-incremental
2176 .RB [ \-\-run ]
2177 .RB [ \-\-quiet ]
2178 .I component-device
2179 .HP 12
2180 Usage:
2181 .B mdadm \-\-incremental \-\-rebuild
2182 .HP 12
2183 Usage:
2184 .B mdadm \-\-incremental \-\-run \-\-scan
2185
2186 .PP
2187 This mode is designed to be used in conjunction with a device
2188 discovery system. As devices are found in a system, they can be
2189 passed to
2190 .B "mdadm \-\-incremental"
2191 to be conditionally added to an appropriate array.
2192
2193 If the device passed is a
2194 .B CONTAINER
2195 device created by a previous call to
2196 .IR mdadm ,
2197 then rather than trying to add that device to an array, all the arrays
2198 described by the metadata of the container will be started.
2199
2200 .I mdadm
2201 performs a number of tests to determine if the device is part of an
2202 array, and which array it should be part of. If an appropriate array
2203 is found, or can be created,
2204 .I mdadm
2205 adds the device to the array and conditionally starts the array.
2206
2207 Note that
2208 .I mdadm
2209 will only add devices to an array which were previously working
2210 (active or spare) parts of that array. It does not currently support
2211 automatic inclusion of a new drive as a spare in some array.
2212
2213 The tests that
2214 .I mdadm
2215 makes are as follow:
2216 .IP +
2217 Is the device permitted by
2218 .BR mdadm.conf ?
2219 That is, is it listed in a
2220 .B DEVICES
2221 line in that file. If
2222 .B DEVICES
2223 is absent then the default it to allow any device. Similar if
2224 .B DEVICES
2225 contains the special word
2226 .B partitions
2227 then any device is allowed. Otherwise the device name given to
2228 .I mdadm
2229 must match one of the names or patterns in a
2230 .B DEVICES
2231 line.
2232
2233 .IP +
2234 Does the device have a valid md superblock. If a specific metadata
2235 version is request with
2236 .B \-\-metadata
2237 or
2238 .B \-e
2239 then only that style of metadata is accepted, otherwise
2240 .I mdadm
2241 finds any known version of metadata. If no
2242 .I md
2243 metadata is found, the device is rejected.
2244
2245 .ig
2246 .IP +
2247 Does the metadata match an expected array?
2248 The metadata can match in two ways. Either there is an array listed
2249 in
2250 .B mdadm.conf
2251 which identifies the array (either by UUID, by name, by device list,
2252 or by minor-number), or the array was created with a
2253 .B homehost
2254 specified and that
2255 .B homehost
2256 matches the one in
2257 .B mdadm.conf
2258 or on the command line.
2259 If
2260 .I mdadm
2261 is not able to positively identify the array as belonging to the
2262 current host, the device will be rejected.
2263 ..
2264
2265 .I mdadm
2266 keeps a list of arrays that it has partially assembled in
2267 .B /var/run/mdadm/map
2268 (or
2269 .B /var/run/mdadm.map
2270 if the directory doesn't exist. Or maybe even
2271 .BR /dev/.mdadm.map ).
2272 If no array exists which matches
2273 the metadata on the new device,
2274 .I mdadm
2275 must choose a device name and unit number. It does this based on any
2276 name given in
2277 .B mdadm.conf
2278 or any name information stored in the metadata. If this name
2279 suggests a unit number, that number will be used, otherwise a free
2280 unit number will be chosen. Normally
2281 .I mdadm
2282 will prefer to create a partitionable array, however if the
2283 .B CREATE
2284 line in
2285 .B mdadm.conf
2286 suggests that a non-partitionable array is preferred, that will be
2287 honoured.
2288
2289 If the array is not found in the config file and its metadata does not
2290 identify it as belonging to the "homehost", then
2291 .I mdadm
2292 will choose a name for the array which is certain not to conflict with
2293 any array which does belong to this host. It does this be adding an
2294 underscore and a small number to the name preferred by the metadata.
2295
2296 Once an appropriate array is found or created and the device is added,
2297 .I mdadm
2298 must decide if the array is ready to be started. It will
2299 normally compare the number of available (non-spare) devices to the
2300 number of devices that the metadata suggests need to be active. If
2301 there are at least that many, the array will be started. This means
2302 that if any devices are missing the array will not be restarted.
2303
2304 As an alternative,
2305 .B \-\-run
2306 may be passed to
2307 .I mdadm
2308 in which case the array will be run as soon as there are enough
2309 devices present for the data to be accessible. For a RAID1, that
2310 means one device will start the array. For a clean RAID5, the array
2311 will be started as soon as all but one drive is present.
2312
2313 Note that neither of these approaches is really ideal. If it can
2314 be known that all device discovery has completed, then
2315 .br
2316 .B " mdadm \-IRs"
2317 .br
2318 can be run which will try to start all arrays that are being
2319 incrementally assembled. They are started in "read-auto" mode in
2320 which they are read-only until the first write request. This means
2321 that no metadata updates are made and no attempt at resync or recovery
2322 happens. Further devices that are found before the first write can
2323 still be added safely.
2324
2325 .SH ENVIRONMENT
2326 This section describes environment variables that affect how mdadm
2327 operates.
2328
2329 .TP
2330 .B MDADM_NO_MDMON
2331 Setting this value to 1 will prevent mdadm from automatically launching
2332 mdmon. This variable is intended primarily for debugging mdadm/mdmon.
2333
2334 .TP
2335 .B MDADM_NO_UDEV
2336 Normally,
2337 .I mdadm
2338 does not create any device nodes in /dev, but leaves that task to
2339 .IR udev .
2340 If
2341 .I udev
2342 appears not to be configured, or if this environment variable is set
2343 to '1', the
2344 .I mdadm
2345 will create and devices that are needed.
2346
2347 .SH EXAMPLES
2348
2349 .B " mdadm \-\-query /dev/name-of-device"
2350 .br
2351 This will find out if a given device is a RAID array, or is part of
2352 one, and will provide brief information about the device.
2353
2354 .B " mdadm \-\-assemble \-\-scan"
2355 .br
2356 This will assemble and start all arrays listed in the standard config
2357 file. This command will typically go in a system startup file.
2358
2359 .B " mdadm \-\-stop \-\-scan"
2360 .br
2361 This will shut down all arrays that can be shut down (i.e. are not
2362 currently in use). This will typically go in a system shutdown script.
2363
2364 .B " mdadm \-\-follow \-\-scan \-\-delay=120"
2365 .br
2366 If (and only if) there is an Email address or program given in the
2367 standard config file, then
2368 monitor the status of all arrays listed in that file by
2369 polling them ever 2 minutes.
2370
2371 .B " mdadm \-\-create /dev/md0 \-\-level=1 \-\-raid\-devices=2 /dev/hd[ac]1"
2372 .br
2373 Create /dev/md0 as a RAID1 array consisting of /dev/hda1 and /dev/hdc1.
2374
2375 .br
2376 .B " echo 'DEVICE /dev/hd*[0\-9] /dev/sd*[0\-9]' > mdadm.conf"
2377 .br
2378 .B " mdadm \-\-detail \-\-scan >> mdadm.conf"
2379 .br
2380 This will create a prototype config file that describes currently
2381 active arrays that are known to be made from partitions of IDE or SCSI drives.
2382 This file should be reviewed before being used as it may
2383 contain unwanted detail.
2384
2385 .B " echo 'DEVICE /dev/hd[a\-z] /dev/sd*[a\-z]' > mdadm.conf"
2386 .br
2387 .B " mdadm \-\-examine \-\-scan \-\-config=mdadm.conf >> mdadm.conf"
2388 .br
2389 This will find arrays which could be assembled from existing IDE and
2390 SCSI whole drives (not partitions), and store the information in the
2391 format of a config file.
2392 This file is very likely to contain unwanted detail, particularly
2393 the
2394 .B devices=
2395 entries. It should be reviewed and edited before being used as an
2396 actual config file.
2397
2398 .B " mdadm \-\-examine \-\-brief \-\-scan \-\-config=partitions"
2399 .br
2400 .B " mdadm \-Ebsc partitions"
2401 .br
2402 Create a list of devices by reading
2403 .BR /proc/partitions ,
2404 scan these for RAID superblocks, and printout a brief listing of all
2405 that were found.
2406
2407 .B " mdadm \-Ac partitions \-m 0 /dev/md0"
2408 .br
2409 Scan all partitions and devices listed in
2410 .BR /proc/partitions
2411 and assemble
2412 .B /dev/md0
2413 out of all such devices with a RAID superblock with a minor number of 0.
2414
2415 .B " mdadm \-\-monitor \-\-scan \-\-daemonise > /var/run/mdadm"
2416 .br
2417 If config file contains a mail address or alert program, run mdadm in
2418 the background in monitor mode monitoring all md devices. Also write
2419 pid of mdadm daemon to
2420 .BR /var/run/mdadm .
2421
2422 .B " mdadm \-Iq /dev/somedevice"
2423 .br
2424 Try to incorporate newly discovered device into some array as
2425 appropriate.
2426
2427 .B " mdadm \-\-incremental \-\-rebuild \-\-run \-\-scan"
2428 .br
2429 Rebuild the array map from any current arrays, and then start any that
2430 can be started.
2431
2432 .B " mdadm /dev/md4 --fail detached --remove detached"
2433 .br
2434 Any devices which are components of /dev/md4 will be marked as faulty
2435 and then remove from the array.
2436
2437 .B " mdadm --grow /dev/md4 --level=6 --backup-file=/root/backup-md4
2438 .br
2439 The array
2440 .B /dev/md4
2441 which is currently a RAID5 array will be converted to RAID6. There
2442 should normally already be a spare drive attached to the array as a
2443 RAID6 needs one more drive than a matching RAID5.
2444
2445 .B " mdadm --create /dev/md/ddf --metadata=ddf --raid-disks 6 /dev/sd[a-f]"
2446 .br
2447 Create a DDF array over 6 devices.
2448
2449 .B " mdadm --create /dev/md/home -n3 -l5 -z 30000000 /dev/md/ddf"
2450 .br
2451 Create a RAID5 array over any 3 devices in the given DDF set. Use
2452 only 30 gigabytes of each device.
2453
2454 .B " mdadm -A /dev/md/ddf1 /dev/sd[a-f]"
2455 .br
2456 Assemble a pre-exist ddf array.
2457
2458 .B " mdadm -I /dev/md/ddf1"
2459 .br
2460 Assemble all arrays contained in the ddf array, assigning names as
2461 appropriate.
2462
2463 .B " mdadm \-\-create \-\-help"
2464 .br
2465 Provide help about the Create mode.
2466
2467 .B " mdadm \-\-config \-\-help"
2468 .br
2469 Provide help about the format of the config file.
2470
2471 .B " mdadm \-\-help"
2472 .br
2473 Provide general help.
2474
2475 .SH FILES
2476
2477 .SS /proc/mdstat
2478
2479 If you're using the
2480 .B /proc
2481 filesystem,
2482 .B /proc/mdstat
2483 lists all active md devices with information about them.
2484 .I mdadm
2485 uses this to find arrays when
2486 .B \-\-scan
2487 is given in Misc mode, and to monitor array reconstruction
2488 on Monitor mode.
2489
2490 .SS /etc/mdadm.conf
2491
2492 The config file lists which devices may be scanned to see if
2493 they contain MD super block, and gives identifying information
2494 (e.g. UUID) about known MD arrays. See
2495 .BR mdadm.conf (5)
2496 for more details.
2497
2498 .SS /var/run/mdadm/map
2499 When
2500 .B \-\-incremental
2501 mode is used, this file gets a list of arrays currently being created.
2502 If
2503 .B /var/run/mdadm
2504 does not exist as a directory, then
2505 .B /var/run/mdadm.map
2506 is used instead. If
2507 .B /var/run
2508 is not available (as may be the case during early boot),
2509 .B /dev/.mdadm.map
2510 is used on the basis that
2511 .B /dev
2512 is usually available very early in boot.
2513
2514 .SH DEVICE NAMES
2515
2516 .I mdadm
2517 understand two sorts of names for array devices.
2518
2519 The first is the so-called 'standard' format name, which matches the
2520 names used by the kernel and which appear in
2521 .IR /proc/mdstat .
2522
2523 The second sort can be freely chosen, but must reside in
2524 .IR /dev/md/ .
2525 When giving a device name to
2526 .I mdadm
2527 to create or assemble an array, either full path name such as
2528 .I /dev/md0
2529 or
2530 .I /dev/md/home
2531 can be given, or just the suffix of the second sort of name, such as
2532 .I home
2533 can be given.
2534
2535 When
2536 .I mdadm
2537 chooses device names during auto-assembly or incremental assembly, it
2538 will sometimes add a small sequence number to the end of the name to
2539 avoid conflicted between multiple arrays that have the same name. If
2540 .I mdadm
2541 can reasonably determine that the array really is meant for this host,
2542 either by a hostname in the metadata, or by the presence of the array
2543 in /etc/mdadm.conf, then it will leave off the suffix if possible.
2544 Also if the homehost is specified as
2545 .B <ignore>
2546 .I mdadm
2547 will only use a suffix if a different array of the same name already
2548 exists or is listed in the config file.
2549
2550 The standard names for non-partitioned arrays (the only sort of md
2551 array available in 2.4 and earlier) are of the form
2552 .IP
2553 /dev/mdNN
2554 .PP
2555 where NN is a number.
2556 The standard names for partitionable arrays (as available from 2.6
2557 onwards) are of the form
2558 .IP
2559 /dev/md_dNN
2560 .PP
2561 Partition numbers should be indicated by added "pMM" to these, thus "/dev/md/d1p2".
2562 .PP
2563 From kernel version, 2.6.28 the "non-partitioned array" can actually
2564 be partitioned. So the "md_dNN" names are no longer needed, and
2565 partitions such as "/dev/mdNNpXX" are possible.
2566
2567 .SH NOTE
2568 .I mdadm
2569 was previously known as
2570 .IR mdctl .
2571 .P
2572 .I mdadm
2573 is completely separate from the
2574 .I raidtools
2575 package, and does not use the
2576 .I /etc/raidtab
2577 configuration file at all.
2578
2579 .SH SEE ALSO
2580 For further information on mdadm usage, MD and the various levels of
2581 RAID, see:
2582 .IP
2583 .B http://linux\-raid.osdl.org/
2584 .PP
2585 (based upon Jakob \(/Ostergaard's Software\-RAID.HOWTO)
2586 .\".PP
2587 .\"for new releases of the RAID driver check out:
2588 .\"
2589 .\".IP
2590 .\".UR ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2591 .\"ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2592 .\".UE
2593 .\".PP
2594 .\"or
2595 .\".IP
2596 .\".UR http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2597 .\"http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2598 .\".UE
2599 .PP
2600 The latest version of
2601 .I mdadm
2602 should always be available from
2603 .IP
2604 .B http://www.kernel.org/pub/linux/utils/raid/mdadm/
2605 .PP
2606 Related man pages:
2607 .PP
2608 .IR mdmon (8),
2609 .IR mdadm.conf (5),
2610 .IR md (4).
2611 .PP
2612 .IR raidtab (5),
2613 .IR raid0run (8),
2614 .IR raidstop (8),
2615 .IR mkraid (8).